Harman Kardon AVR 160 EMC - CB Certificate ▷ View online
- Page 5 of 43 -
Report
No.
129949
TRF No. IEC60065_I
Test item particulars ...................................................:
A/V Surround Receiver
Classification of installation and use ............................:
Class II
Supply connection .......................................................:
By non-detachable power supply cord
to mains socket.
to mains socket.
.......................................................................................:
.......................................................................................:
Possible test case verdicts:
- test case does not apply to the test object ................ :
N/A
- test object does meet the requirement ...................... :
P (Pass)
- test object does not meet the requirement ................ :
F (Fail)
Testing…………………………………………....:
Date of receipt of test item ...................................... :
May, 2009
Date(s) of performance of tests:
May, 2009 – June, 2009
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (comma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report, a point (comma) is used as the decimal separator.
List of test equipment must be kept on file and available for review.
General product information:
The apparatus under test is AV Surround Receiver of insulation class II.
The apparatus has amplifier circuits (Front, Center, Surround, Surround Back), Tuner circuit,
Several Signal In/Out terminals (RCA, Optical, HDMI, USB, Mini jack) and Speaker terminals
(See also photos).
The apparatus under test is AV Surround Receiver of insulation class II.
The apparatus has amplifier circuits (Front, Center, Surround, Surround Back), Tuner circuit,
Several Signal In/Out terminals (RCA, Optical, HDMI, USB, Mini jack) and Speaker terminals
(See also photos).
- Page 6 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
3 General
requirements
Safety class of the apparatus ………………………:
Class II apparatus.
P
4 General
test
conditions
4.1.4
Ventilation instructions require the use of the test
box
box
No test box required.
Tested according to
manufactures instructions.
Tested according to
manufactures instructions.
N/A
5 Marking
and
instructions
Comprehensible and easily discernible ………...:
On front and rear side of the
enclosure
enclosure
P
Permanent durability against water and petroleum
spirit ……………………………………………..:
spirit ……………………………………………..:
Tested with water / sprit
P
5.1
a) Identification, maker ………………………..:
Brand name : Harman/Kardon.
See copy of marking plate.
See copy of marking plate.
P
b) Model number or type reference ………………..:
AVR 160/230
P
c) Class II symbol if applicable ………………..:
Class II symbol is applied in
according to IEC 60417-5172
according to IEC 60417-5172
P
d) Nature of supply ………………………….....:
a.c. symbol is applied in
according to IEC 60417-5032
according to IEC 60417-5032
P
e) Rated supply voltage and symbol ………………:
230-240V and
AC-symbol ( ~ ) used.
AC-symbol ( ~ ) used.
P
f) Mains frequency if safety dependant ......…….:
50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ………:
apparatus supplied by supply apparatus for general
use ………:
The apparatus is connection to
an a.c. mains supply
an a.c. mains supply
N/A
Measured current or power consumption ………...:
N/A
Deviation % (max 10%) ………………....:
N/A
h) Power consumption marking for apparatus other
than single phase ………..……….:
than single phase ………..……….:
The apparatus is connection
to an a.c. mains supply.
to an a.c. mains supply.
N/A
i) Rated current or power consumption for apparatus
intended for connection to an a.c. mains supply …:
intended for connection to an a.c. mains supply …:
300W
P
Measured current or power consumption ….....:
302.7W
(see appended table 7.1)
(see appended table 7.1)
P
Deviation % (max 10%) …………………………....:
Exceed the marked value,
but within deviation 10%.
but within deviation 10%.
P
- Page 7 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
5.2
Earth terminal ………………………..:
Class II apparatus
N/A
Hazardous live terminals ………………:
No hazardous live terminals.
The output signal will rise to
33Vp at maximum out power
if the speaker load is
disconnected in the speaker
terminal, No hazard.
The output signal will rise to
33Vp at maximum out power
if the speaker load is
disconnected in the speaker
terminal, No hazard.
P
Supply output terminals (other than mains) ……..:
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
Use of triangle with exclamation mark …….:
Correct symbol applied:
- In rear side in connection
with CAUTION of opening,
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
- In rear side in connection
with CAUTION of opening,
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
P
5.4
Instructions for use ……………………….:
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc. ……….:
dripping or splashing. Warning concerning objects
filled with liquid, etc. ……….:
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring:
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery …..:
No lithium battery in the
equipment.
equipment.
N/A
d) Class I earth connection warning ………….:
Class II equipment
N/A
e) Instructions for multimedia system connection :
Instructions for multimedia
system connection provided in
user manual.
system connection provided in
user manual.
P
f) Special stability warning for attachment of the
apparatus to the flor/wall ………………………:
apparatus to the flor/wall ………………………:
No such equipment
N/A
g) Warning: battery exposure to heat ……………..:
No battery
N/A
h) Warning: protective film on CRT face ………….:
No CRT
N/A
- Page 8 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings …….:
switch location, accessibility and markings …….:
Plug is regarded as
disconnect device and is
readily operable.
disconnect device and is
readily operable.
P
Instructions for permanently connected
equipment ...:
equipment ...:
Not permanent connected
equipment
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains …………...…:
disconnection from the mains …………...…:
Information provided in user
manual.
manual.
P
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h) ………….:
No ionizing radiation
N/A
Ionizing radiation under fault condition …………….:
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ….:
No laser radiation
N/A
Emission limits under fault conditions …………..:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated .:
fuse links and other protective devices defeated .:
No fuse links operate during
normal operating operation.
(see appended table)
normal operating operation.
(see appended table)
P
7.1.1
Temperature rise of accessible parts ………………..:
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation:
insulation:
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier …………………………………..:
mechanical barrier …………………………………..:
(see appended table 7.1)
P
7.1.4
Temperature rise of windings ……………………:
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C :
See appended table 7.2 for
AC connector (wafer) CN91
and CN92.
AC connector (wafer) CN91
and CN92.
P
Click on the first or last page to see other AVR 160 service manuals if exist.