Harman Kardon AVR 160 EMC - CB Certificate ▷ View online
- Page 9 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
8
Constructional requirements with regard to the protection against electric shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare …………:
untreated textile oxide films and beads etc.
considered to be bare …………:
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
………….:
device, fuse-links or handling drawers etc.
………….:
Operation “By hand” not
possible
possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material ………..:
hygroscopic material ………..:
No hygroscopic materials
used
used
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand:
from parts rendered accessible following the
removal of a cover which can be removed by hand:
No cover removable by hand
N/A
8.5
Class I equipment …………………...:
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts ……………………………:
earthed accessible parts ……………………………:
N/A
Resistors bridging basic insulation complying with
14.1 a) ……………..:
14.1 a) ……………..:
No such resistors
N/A
Capacitors bridging basic insulation complying with
14.2.1 a) ……………………….......:
14.2.1 a) ……………………….......:
No such capacitors
N/A
Protective earthing terminal …………...:
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment …………………...:
Class I equipment …………………...:
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts ………..:
live parts and accessible parts ………..:
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3 ……..:
complying with 14.1 a) or 14.3 ……..:
The apparatus has isolating
transformers complies with
clause 14.3
transformers complies with
clause 14.3
P
Basic insulation bridged by components complying
with 14.3.4.3. ………………………...:
with 14.3.4.3. ………………………...:
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a) …:
bridged by a capacitor complying with 14.2.1 a) …:
No such capacitors.
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a) …….:
capacitors in series complying with 14.2.1 a) …….:
No such capacitors.
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b) ………:
single capacitor complying with 14.2.1 b) ………:
No such capacitors
N/A
- Page 10 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
8.7
This clause is void ………………………..:
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced insulation > 0,4 mm (mm) ……:
Bobbin in main and sub
transformer. (ref. 14.3)
transformer. (ref. 14.3)
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22) ………:
sheet insulation. See 8.22) ………:
No thin sheet insulation.
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 ….....:
layers, each meeting 10.3 ….....:
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 ………………......:
two of which meet 10.3 ………………......:
N/A
Reinforced insulation, two layers each of which meet
10.3 ……...:
10.3 ……...:
N/A
Reinforced insulation, three layers any two which
meet 10.3 ……………………….:
meet 10.3 ……………………….:
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
……………………..:
conductors and accessible parts
……………………..:
Double insulated
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts:
parts and conductors connected to accessible parts:
Single insulation, but safely
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts. …………………...:
the mains and accessible parts. …………………...:
Double insulated according to
8.9. and 10.3
8.9. and 10.3
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts:
parts and conductors connected to accessible parts:
Single insulation, but safely
anchored.
anchored.
N/A
8.11
Detaching of wires …………………………………..:
P
No undue reduction of creepages or clearance
distances if wires become detached ……………:
distances if wires become detached ……………:
Primary wires are connected
with multi-contact-housing
with multi-contact-housing
P
Vibration test carried out …………:
See 12.12
N/A
8.12
This clause is void ………………..:
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s) …………………...:
etc. (pull test 20 N for 10 s) …………………...:
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N
for 10 s) ……………………..:
for 10 s) ……………………..:
Covers adequately
fastened with screws.
fastened with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges …………:
due to hot parts or sharp edges …………:
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used :
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
- Page 11 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
8.17
Insulated winding wire without additional interleaved
insulation ……………………………………………..:
insulation ……………………………………………..:
No such winding wire.
N/A
8.18
Endurance test as required by 8.17 ……………….:
N/A
8.19
Disconnection from the mains
See below
N/A
8.19.1
Disconnect device ………………………………......:
Mains plug is used as
disconnect devices
disconnect devices
P
All-pole switch or circuit breaker with >3mm contact
separation ……………………:
separation ……………………:
No all-pole switch or circuit
breaker.
breaker.
N/A
8.19.2 Mains
switch
ON indication …………………...:
Indicator lamp or FL display
lit-on for mains switch ON
indication, but switch is single
pole only.
lit-on for mains switch ON
indication, but switch is single
pole only.
P
8.20
Switch not fitted in the mains cord …………:
No such application of the
mains switch
mains switch
P
8.21
Bridging components comply with clause 14 ….:
C904capacitor, bridging
contact gaps of the mains relay.
Certified component.
See appended table, list of
critical components.
contact gaps of the mains relay.
Certified component.
See appended table, list of
critical components.
P
8.22 Non-separable
thin
sheet material …………...:
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation ……….:
with clause 13.3.1 for basic insulation ……….:
No voltage exceeding
1000V ac or 1500V dc.
1000V ac or 1500V dc.
N/A
9.1.1.1
a) Open circuit voltages …………………….:
Mains input voltage
> 35 Vac, see below.
> 35 Vac, see below.
⎯
b) Touch current measured from terminal devices
using the network in annex D ………………………:
using the network in annex D ………………………:
(see appended table 9.1.1.1)
P
c) Discharge not exceeding 45 μC ……...:
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ:
No part or contact of a terminal
with stored voltages exceeding
15kV.
with stored voltages exceeding
15kV.
N/A
9.1.1.2
Test with test finger and test probe …...:
No access to hazardous
live parts
live parts
P
- Page 12 of 43 -
Report
No.
129949
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
9.1.2
No hazardous live shafts of knobs, handles or
levers:
levers:
No live shaft, handles or levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin ……:
4 mm x 100 mm test pin ……:
No access for the test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032 …………………:
(10 N); test probe D of IEC 61032 …………………:
Does not reach hazardous live
parts
parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032 ……:
straight wire (1 N); test probe D of IEC 61032 ……:
Does not reach hazardous live
parts
parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
……………….:
pin (10 N); test probe C of IEC 61032
……………….:
No preset controls
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s …:
withdrawal of the mains plug; voltage (V) after
2 s …:
See below
N/A
If C is not greater than 0,1 μF no test needed ……:
<
0,1 μF
P
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N) …...:
Test with test finger
result in no hazard
result in no hazard
P
b) Test hook of fig. 4 for 10 s (20 N) ……:
Test with test hook results in
no hazard.
no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N) :
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand ……….:
No cover removable by hand
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ……………………………………………..:
surge test for basic and 4 MΩ min. for reinforced
insulation ……………………………………………..:
> 100 M
Ω after surge test
P
10.2
Humidity treatment 48 h or 120 h ………………….:
Performed for 120 h at temp.
40
40
°C and humidity 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals ……………………………………...:
mains terminals ……………………………………...:
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1) :
BASIC or SUPPLEMENTARY insulation (Class 1) :
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II) ……………..:
REINFORCED insulation (Class II) ……………..:
(see appended table 10.3)
P