Harman Kardon AVR 160 EMC - CB Certificate ▷ View online
- Page 33 of 43 -
Report
No.
129949
TRF No. IEC60065_I
7.1
TABLE: temperature rise measurements
P
Monitored point:
dT (K) at
207V / 50Hz
dT (K) at
264V / 50Hz
dT (K) at
207V / 60Hz
dT (K) at
264V / 60Hz
Permitted
dT (K)
Main transformer core
62.4 77.5
60.6 74.5
95
Sub transformer core
36.7
42.9
36.1
41.1
85
PWB near D105
34.6
40.1
34.5
40.0
95
PWB near D991
65.2
66.4
64.4
66.7
95
PWB near Q803
44.7
59.8
44.6
58.5
95
PWB near IC83
48.1
66.2
48.2
64.6
95
FAN body (installed in main heat-sink)
24.7
31.6
25.0
29.1
-
E Capacitor, C129 body
33.2 41.4
33.4 39.5
85
°C
E Capacitor, C916 body
27.6 33.8
27.3 32.9
85
°C
CN91 AC connector
25.2 31.3
25.0 31.2
200
°C *)
CN92 AC connector
28.4 34.0
28.1 33.6
200
°C *)
Heat-sink of D991
87.8
91.0
88.8
90.8
-
Main heat-sink
49.3
66.6
49.4
65.4
-
Power cord bushing
25.8
28.3
25.3
28.9
60
Enclosure top above main transformer
24.8
32.9
24.8
32.5
40
Enclosure top above main heat-sink
30.0
38.0
30.3
36.6
40
Mains switch (rear side)
12.4
15.9
12.4
15.6
50
Stand-by button (non-metallic)
2.8
6.4
4.5
10.2
50
Front panel (non-metallic) 10.0
14.6
10.9
16.5
60
Ambient 23.4°C
21.8°C
23.3°C
23.0°C
-
*) Based on softening temperature test (see table 7.2).
- Page 34 of 43 -
Report
No.
129949
TRF No. IEC60065_I
Winding temperature rise
measurements
measurements
207V
50Hz
50Hz
264V
50Hz
50Hz
207V
60Hz
60Hz
264V
60Hz
60Hz
—
Ambient temperature t1 (
o
C) :
22.0 22.0 22.0 22.0
—
Ambient temperature t2 (
o
C) :
23.4 21.8 23.3 23.0
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Permitted
dT (K)
Insulation
class
Main transf. primary winding (264V, 50Hz)
2.663
3.636
93.9
95
B
Sub transf. primary winding (264V, 50Hz)
3593
4278
49.1
85
E
Main transf. primary winding (264V, 60Hz)
2.663
3.635
92.6
95
B
Sub transf. primary winding (264V, 60Hz)
3593
4281
48.1
85
E
Main transf. primary winding (207V, 60Hz)
2.663
3.448
74.3
95
B
Sub transf. primary winding (207V, 60Hz)
3593
4200
42.0
85
E
Main transf. primary winding (207V, 50Hz)
2.663
3.462
75.6
95
B
Sub transf. primary winding (207V, 50Hz)
3593
4203
42.1
85
E
- Page 35 of 43 -
Report
No.
129949
TRF No. IEC60065_I
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T - normal conditions
(
o
C)
T - fault conditions
(
o
C)
Min T softening
(
o
C)
Mains connector (CN91)
31.2 (54.2 °C)
(I/P=264V, ambient
23.0 °C)
(I/P=264V, ambient
23.0 °C)
38.8 (63.0 °C)
(I/P=264V, ambient
24.2 °C)
(I/P=264V, ambient
24.2 °C)
> 200
(type, YW396 series)
Mains connector (CN92)
33.6 (56.6 °C)
(I/P=264V, ambient
23.0 °C)
(I/P=264V, ambient
23.0 °C)
42.0 (66.2 °C)
(I/P=264V, ambient
24.2 °C)
(I/P=264V, ambient
24.2 °C)
> 200
(type, YW396 series)
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location
Measured
U1V (peak)
U1V (peak)
Measured
U1 V (DC)
U1 V (DC)
Measured
U2 V (peak)
U2 V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 – Antenna Terminal
Pole 2 - Antenna Terminal
Pole 2 - Antenna Terminal
-
-
-
-
-
-
0.03V peak
0.02V peak
0.02V peak
Pass
Pass
Pass
Pole 1 - other part or contact
Pole 2 - other part or contact
Pole 2 - other part or contact
-
-
-
-
-
-
0.03V peak
0.02V peak
0.02V peak
Pass
Pass
Pass
Comments:
Vin=264Vac, 60Hz
Only U2 have been recorded due to the use of a linear transformer in power supply.
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
Min 2
Between parts separated by double or reinforced insulation
> 100
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500Vac No
Between parts separated by double or reinforced insulation
3000Vac No
- Page 36 of 43 -
Report
No.
129949
TRF No. IEC60065_I
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 207V or 264V
—
Ambient
temperature
(
o
C) ...................................... : 22
o
C - 27
o
C
—
Monitored point:
Under fault conditions specified below
Under fault conditions specified below
dT (K)
Permitted
dT (K)
1. *), D114 (A to C), SC, 30 min;
Normal operation, FI stabilised at 1.72A, R104 opened, No hazard.
Normal operation, FI stabilised at 1.72A, R104 opened, No hazard.
N/A N/A
2. *), D117 (A to C), SC, 10 min;
Normal operation, FI stabilised at 1.72A, R105 opened, No hazard.
Normal operation, FI stabilised at 1.72A, R105 opened, No hazard.
N/A N/A
3. *), D991 (AC to +), SC, 10 min;
F901 opened immediately, FI stabilised at 0.016A, D991 damaged,
No hazard.
F901 opened immediately, FI stabilised at 0.016A, D991 damaged,
No hazard.
N/A N/A
4. **), D991 (AC to -), SC, 10 min;
F901 opened immediately, FI stabilised at 0.012A, No hazard.
F901 opened immediately, FI stabilised at 0.012A, No hazard.
N/A N/A
5. *), D104 (A to C), SC, 30 min;
Normal operation, FI stabilised at 1.70A, F111 opened, No hazard.
Normal operation, FI stabilised at 1.70A, F111 opened, No hazard.
N/A N/A
6. *), D105 (A to C), SC, 30 min;
Normal operation, FI stabilised at 1.70A, F110 opened, No hazard.
Normal operation, FI stabilised at 1.70A, F110 opened, No hazard.
N/A N/A
7. **), D105 (A to C), SC, 10 min;
Normal operation, FI stabilised at 1.60A, F110 opened, No hazard.
Normal operation, FI stabilised at 1.60A, F110 opened, No hazard.
N/A N/A
8. *), IC81 (pin2 to pin3), SC, 10 min;
Normal operation, FI stabilised at 1.72A, NCD, No hazard.
Normal operation, FI stabilised at 1.72A, NCD, No hazard.
N/A N/A
9. *), C129, SC, 10 min;
Signal output and FL display off immediately, FI stabilised at 0.58A,
F110 and F111 opened, No hazard.
Signal output and FL display off immediately, FI stabilised at 0.58A,
F110 and F111 opened, No hazard.
N/A N/A
10. *), IC83 (pin1 to pin2), SC, 10 min;
Normal operation, FI stabilised at 1.72A, NCD, No hazard.
Normal operation, FI stabilised at 1.72A, NCD, No hazard.
N/A N/A
11. *), C929, SC, 10 min;
Signal output off immediately, FI stabilised at 0.58A, R104 and R105 opened,
No hazard.
Signal output off immediately, FI stabilised at 0.58A, R104 and R105 opened,
No hazard.
N/A N/A
12. *), C915, SC, 10 min;
F901 opened immediately, FI stabilised at 0.016A, No hazard.
F901 opened immediately, FI stabilised at 0.016A, No hazard.
N/A N/A
13. **), C916, SC, 10 min;
F901 opened immediately, FI stabilised at 0.012A, No hazard.
F901 opened immediately, FI stabilised at 0.012A, No hazard.
N/A N/A
14. *), Q805 (C to E), SC, 10 min;
Unit shut down immediately, FI stabilised at 0.009A, Q807, Q851,
R820 and R811 damaged, No hazard.
Unit shut down immediately, FI stabilised at 0.009A, Q807, Q851,
R820 and R811 damaged, No hazard.
N/A N/A
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264V **) Tested voltage 207V
Click on the first or last page to see other AVR 160 service manuals if exist.