Report No. 65586
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
No TNV circuits
N
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus.
N
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT in the equipment
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N
IT: certification number on the back cover
N
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No switches containing
mercury
mercury
N
TRF No: IEC/EN 60065F
- IEC 60065 7
th
edition (2001)
- Page 1 of 1 -
Order No. 65586
TRF No: IEC/EN 60065F
APPENDIX: SINGAPORE DEVIATIONS
to IEC 60065 7
th
ed. (2001)
(CB Bulletin No. 105A, May 2003)
Clause
Requirement – Test
Result - Remark
Ver-
dict
4
All apparatus must be tested to 230 Vac
230 Vac tested
P
4.3.13
Apparatus fitted with voltage selector switch must
be tested as follows:
be tested as follows:
Connect apparatus to 230 V ac mains with voltage
selector switch to settings not suitable for operation
at 230 V ac.
selector switch to settings not suitable for operation
at 230 V ac.
No voltage selector.
N
5.3
Circuit diagrams must be indicated with component
values.
values.
P
Circuit diagrams of electronic modules in the
apparatus must be provided.
apparatus must be provided.
P
7.1, 11.2
Permissible temperature rises of 10K less than
those specified in Table 2 are required.
those specified in Table 2 are required.
Meets tropical limits
P
10.2
Humidity treatment. Adopt the testing conditions
designed for tropical conditions.
designed for tropical conditions.
5 days
P
15.1.1
All Class I apparatus must be fitted with 3-pin mains
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
plugs that comply with SS 145/SS 472 that are
registered with the Safety Authority
Class II apparatus
N
a) All Class II apparatus must be fitted with 2-pin
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
mains plugs (Appendix W) that comply with IEC
83:1975 (Standard C5, Version II) or EN 50075.
N
b) Class II apparatus that are fitted with 3-pin mains
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
plugs must use plugs that comply with SS 145 and
registered with the Safety Authority.
PSB approved plug provided
P
15.3
Apparatus ≥ 3 kW must be connected to fixed
wiring. All connection to fixed wiring must be in
accordance with Code of Practice CP5.
accordance with Code of Practice CP5.
< 3 kW
N
16
Detachable power cord set must be listed in the test
report critical component list.
report critical component list.
Not detachable
N
Misc.
Apparatus enclosure which is shaped and
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
decorated so that it is likely to be treated as a toy
by children, shall not be accepted for certification
and registration.
Not shaped like toy.