Harman Kardon AVR 140 (serv.man4) EMC - CB Certificate ▷ View online
- Page 24 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60707 with
openings not exceeding 1 mm in width
N
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-1 and exception is made for
small componets.
V-1 and exception is made for
small componets.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 Kv or leaving an internal fire enclosure, not
contributing to the spread of fire
No wires working at voltages
> 4kV or leaving an internal
fire enclosure
> 4kV or leaving an internal
fire enclosure
N
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
available power exceeds 15 W at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets
V-1 or better to IEC60707, unless used in a fire
enclosure
All PCB is of base material
with flammability category V-1
or better. See appended table
with flammability category V-1
or better. See appended table
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
No such components
N
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N
20.2 Fire
enclosure
N
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N
20.2.2
Internal fire enclosures with openings not
exceeding 1 mm in width and with openings for
wires completely filled
exceeding 1 mm in width and with openings for
wires completely filled
No internal fire enclosure.
N
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosure.
N
TRF No: IEC/EN 60065F
- Page 25 of 32 -
www.nemko.com
Report No. 65586
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N
A.10.2.1
Enclosure provides protection against splashing water
N
A.10.2.2 Humidity
treatment carried out for 7 days
N
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No connection to TNV circuits
N
Complies with IEC 62151 clause 2
N
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this standard
modified in accordance with annex B of this standard
N
Complies with IEC 62151 clause 6
N
Complies with IEC 62151 clause 7
N
Complies with IEC 62151 annex A, B and C
N
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a non-
industrial appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that the
equipment must be connected to an earthed mains
socket-outlet.
The marking text in the applicable countries shall be
as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla va
rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N
TRF No: IEC/EN 60065F
- Page 26 of 32 -
www.nemko.com
Report No. 65586
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is less
than 3,2W.
the power consumption is less
than 3,2W.
P
Position of the functional switch (W) ...................... :
—
Operating conditions
Standby mode:
Un (V)
In (A)
Pn (W)
Pout (W)
207 0,016 2,4 —
230 0,016 2,8 —
253 0,014 3,2 —
Measured at maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
253
3,05
658
2 x 52,0 W
(F)
1 x 51,5 W
(C)
2 x 52,5 W
(S)
1 x 54,1 W
(S/B)
Measured at 1/8 of maximum non-clipped output:
Un (V)
In (A)
Pn (W)
Pout (W)
207
1,37
221
2 x 6,5 W
(F)
1 x 6,4 W
(C)
2 x 6,6 W
(S)
1 x 6,8 W
(S/B)
230
1,40
249
2 x 6,5 W
(F)
1 x 6,4 W
(C)
2 x 6,6 W
(S)
1 x 6,8 W
(S/B)
253
1,45
282
2 x 6,5 W
(F)
1 x 6,4 W
(C)
2 x 6,6 W
(S)
1 x 6,8 W
(S/B)
Loudspeaker impedance (Ω) ....................
8 Ohm
—
Several loudspeaker systems
Right and Left for Front,
Only one for Center,
Right and Left for Surround,
Only one for Surround Back channels.
Only one for Center,
Right and Left for Surround,
Only one for Surround Back channels.
—
Marking of loudspeaker terminals
SPEAKERS ( 8Ω ): FRONT, CENTER,
SURROUND, SURR. BACK,
—
TRF No: IEC/EN 60065F
- Page 27 of 32 -
www.nemko.com
Report No. 65586
Monitored point:
dT (K)
at 207V
dT (K)
at 253V
Limit dT (K)
*)
Main transformer core
50,8
60,0
95
Sub transformer core
33,2
43,1
85
D991 heat-sink
52,6
57,2
-
Diode, D992 body
50,4
53,9
-
D992 heat-sink
50,7
54,8
-
PWB near D992
47,3
51,5
85
TR, Q803 body
45,6
57,6
-
TR, Q804 body
30,5
39,0
-
PWB near Q803
38,4
48,3
85
E. Capacitor, C909 body
25,2
29,0
85℃
E. Capacitor, C928 body
25,8
30,7
85℃
E. Capacitor, C905 body
32,5
36,9
85℃
IC93 body
41,2
52,5
-
PWB near IC93
42,5
54,7
85
Main heat-sink
44,9
56,8
-
Power cord bushing
20,3
23,2
60
Top enclosure above main transformer
24,7
29,5
40
Top enclosure above main heat-sink
29,6
37,2
65 **)
Power switch button
0,2
0,6
50
*) Temperature rise limits for Singapore is 10K less
**) Directly covering part for heat-sink. The top cover is supplied with ventilation openings covering most of
the top cover. This indicate emission of heat from internal parts and the opening area is therefore not likely
to be touched during normal use.
the top cover. This indicate emission of heat from internal parts and the opening area is therefore not likely
to be touched during normal use.
Winding temperature rise measurements
207V
253V
—
Ambient temperature t1 (
o
C) :
25,4
25,4
—
Ambient temperature t2 (
o
C) :
26,2
25,0
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit dT (K) Insulation
class
Main transf. pr. winding (207V)
3,19
4,10
73,3
95
B
Sub transf. pr. winding (207V)
2743 3161 38,8 85
E
Main transf. pr. winding (253V)
3,19
4,22
84,3
95
B
Sub transf. pr. winding (253V)
2743 3295 52,7 85
E
TRF No: IEC/EN 60065F
Click on the first or last page to see other AVR 140 (serv.man4) service manuals if exist.