- Page 12 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
No excessive temperature 
observed/measured on other 
parts 
 
 
 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test where mass >7 kg 
No damage in the sense of 
this standard 
12.1.2 Vibration 
test 
Assessed to be satisfactory 
constructed. 
12.1.3 
Impact hammer test 
No damage in the sense of 
this standard 
 
Steel ball test 
Complies 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
Not a portable apparatus. 
12.1.5 
Thermoplastic enclosures strain relief test 
Tested, 70ºC, 7h 
12.2 
Fixing of knobs, push buttons, keys and levers 
Normal use will not impair the 
protection against electric 
shock. 
12.3 
Remote controls with hazardous live parts 
No remote controllers with 
hazardous live parts. 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawers 
12.5 
Antenna coaxial sockets providing isolation 
No antenna socket which 
insolate hazardous live parts from 
accessible parts. 
12.6 
Telescoping or rod antennas construction 
No antenna
 
12.6.1 
Telescoping or rod antennas securement 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 13 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
 
Creepage distances in accordance with 13.4 
See attachment, Table to 
EN/IEC 60065 7
th
 edition. 
13.2 
Determination of operating voltage 
Conventional transformer 
used. 
Upper rated supply voltage 
applied in determining the 
operating voltage. 
13.3 Clearances 
2N for internal parts and 30N 
for enclosures are considered 
when determining clearances.
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
No hazardous secondary 
voltages 
13.4 Creepage 
distances 
CTI > 100 
See attachment, Table to 
EN/IEC 60065 7
th
 edition 
 
Creepage distances greater than table 11 minima 
Not applicable 
13.5 Printed 
boards 
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
No type B coated PWB
 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
Jointed insulation not applied 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
No enclosed, enveloped or 
hermetically sealed parts 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No parts filled with insulating 
compound 
TRF No:  IEC/EN 60065F 
 
 
- Page 14 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14 COMPONENTS 
 
14.1 Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
Not used 
 
b) Resistors separately approved .......................... :
 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes, 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. :
No Y capacitors 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. :
C124, C853 (Optional) and 
C904 are Certified X capacitor 
by IEC 60384-14, 2
nd
 edition  
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... :
No such capacitors 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Several E. cap. Vol. >1750mm
3
but metal cases. 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Several E. cap. Vol. >1750mm
3
but metal cases. 
 
Shielded by a barrier to V-0 or metal  ..................... :
 
14.3 
Inductors and windings 
See below. 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
Transformers evaluated  
according to 14.3.3, 14.3.4  
and 14.3.5 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ............................... :
Adequate marking applied. 
- Type no. and, 
-.Manufacturer’s ID  
 
Transformers and inductors separately approved . :
No 
14.3.2 General 
Isolating transformer 
14.3.3 Constructional 
requirements 
 
TRF No:  IEC/EN 60065F 
 
 
- Page 15 of 32 - 
 
 
www.nemko.com
 
Report No.  65586 
 
 
IEC/EN 60065
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
See attachment, Table to  
EN/IEC 60065 7
th
 edition 
14.3.3.2 
Transformers meet the constructional 
requirements 
See attachment, Table to  
EN/IEC 60065 7
th
 edition 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation  
between primary and secondary  
windings according to clause 8.8. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the 
requirement 
of reinforced insulation; bobbin 
thickness > 0,4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II apparatus. No such 
transformer used. 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between hazardous live 
windings and accessible 
conductive parts. 
 
Coil formers and partition walls > 0,4 mm 
The bobbin fulfils the 
requirement 
of reinforced insulation; bobbin 
thickness > 0,4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Windings of Class II 
construction used. 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 
14.4 
High voltage components 
No high voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
TRF No:  IEC/EN 60065F 
Page of 48