DOWNLOAD Harman Kardon AVR 135 (serv.man2) Service Manual ↓ Size: 4.88 MB | Pages: 127 in PDF or view online for FREE

Model
AVR 135 (serv.man2)
Pages
127
Size
4.88 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-135-sm2.pdf
Date

Harman Kardon AVR 135 (serv.man2) EMC - CB Certificate ▷ View online

 
Anam Electronics Co., Ltd. 
                                    Page 4 of 15 
AVR135/230 
EMC Test Report
 
         
Reference No.:NK2EE903
 
2. Equipment Under Test (EUT) 
 
2.1 Identification of EUT
 
   
Category:
 
AV Receiver 
Model Name:
 
AVR135/230 
Brand Name:
 
Harman kardon 
Serial Number:
 
N/A
 
Voltage:
 
230Vac, 50Hz, 350W 
In/Out Port: 
S-Video In x 4EA, S-Video Out x 2EA, Audio In L/R x 6EA,   
 
Audio Out L/R x 2EA, Composite Video In x 4EA, 
 
Composite Video Out x 2EA, 8CH Direct In x 1EA,   
 
Component Video In x 2EA, Component Video Out x 1EA, 
 
Pre Out x 1EA, Optical In x 3EA, Optical Out x 1EA, Coaxial In x 3EA, 
 
Coaxial Out x 1EA, Antenna FM x 1EA, Antenna AM x 1EA,   
 
Headphone Jack x 1EA 
Remarks:
 
 
 
2.2 Variants Covered By This Report
 
       
ID No. 
Model Name 
Technical Deviations From Reference Model 
N/A N/A 
 
 
2.3 Modifications
 
         
      ●No modifications. 
   
2.4 Additional Information Related To Testing 
 
      ●No comment. 
   
 
Anam Electronics Co., Ltd. 
                                    Page 5 of 15 
AVR135/230 
EMC Test Report
 
         
Reference No.:NK2EE903
 
3. General Test Conditions 
 
3.1 Location 
 
NEMKO KOREA Co., Ltd. 
    300-2, Osan-Ri, Mohyun-Myun, Yongin-City, Kyungki-Do, Korea. 449-852 
      Phone : +82 31 322 2333           Fax : +82 31 322 2332 
 
 
3.2 Operating Environment 
       
      All tests and measurements were performed in a shielded enclosure or a controlled environment 
      suitable for the tests conducted. The climatic conditions in the test area are automatically controlled   
   and recorded continuously. 
 
Parameters Recording 
during test 
Accepted deviation 
Ambient temperature 
22.0℃ 
15 - 35℃ 
Relative humidity 
41.0% 
30 - 60% 
Atmospheric pressure 
100.3kPa 
86-106kPa 
 
3.3 Operating During Test 
 
●The EUT was set to DVD, CD and Aux input with a continuous 1kHz sinusoidal signal. 
 
3.4 Test Equipment 
       
      ●The test equipment used in testing are calibrated on a regular basis. For most of the testing   
          equipment accredited calibration is conducted once a year. For certain equipment the calibration   
          interval is longer. Between the calibrations all test equipment are controlled and verified on a   
          regular basis. The test equipments used are defined in each test section of this report. 
 
3.5 EUT & Support Equipment 
 
Equipment Manufacturer 
Model 
 
Serial 
Number 
AV Receiver (EUT) 
Anam Electronics Co.,Ltd.
AVR135/230 
N/A 
Oscilloscope 
EZ Digital Co., Ltd. 
OS-5060A 
1040214 
Audio Signal Generator 
EZ Digital Co., Ltd. 
AG-7001C 
01080411 
Speaker BIG 
BEAM 
BDS 
2002S 
N/A 
 
 
 
Anam Electronics Co., Ltd. 
                                    Page 6 of 15 
AVR135/230 
EMC Test Report
 
         
Reference No.:NK2EE903
 
4. Evaluation Of Performance 
 
4.1 Performance Criteria 
 
      Criteria A 
The equipment shall continue to operate as intended during the test. 
No change of actual operating state is allowed as result of the application of the test. 
Multifunction equipment shall for each function meet the relevant requirements. 
Evaluation is carried out for audio and video functions. 
6. 
Evaluation of audio quality 
The criterion of compliance with the requirement is a wanted to unwanted audio signal ratio of  ≥40Db  
at a wanted audio signal level of 500Mv, or at another audio signal level specified by the manufacturer. 
2) Evaluation of picture quality 
In the evaluation of picture interference the wanted test signal produces a standard picture and the 
unwanted signal produces a degradation of picture. The degradation may be in a number of forms,   
such as a superposed pattern, disturbance of synchronization, geometrical distortion, loss of picture   
contrast, of color. 
The criterion of compliance with the requirement is just perceptible degradation by observation of 
the picture. The screen shall be observed under normal viewing conditions (brightness 15 lx to 20 lx), 
at a viewing distance of six times the height of the screen. 
 
      Criteria B 
The device shall continue to operate as intended after the test. No loss of function is allowed after   
the test when the apparatus is used as intended, but failures which are recovered automatically   
but which cause temporary delay in processing, are permissible. No change of actual operating   
state for example change of channel or stored data and settings is allowed as a result of the application 
of the test. During the test, degradation of performance is allowed.   
 
4.2 Measurement Uncertainty 
 
   Measurement uncertainty is calibrated in accordance with: 
      ●EMCIT document 93/30 
      ●NAMAS Information Sheet NIS81,Ed.1 May 1994 
(The treatment of uncertainties in EMC measurement). 
      The measurement uncertainty is not considered when deciding PASS or FAIL against the limit lines. 
      This means that “shared risk” (according to NAMAS publication NIS81 4.2) is used as option   
      Criterion. The argument for using this method, is that it is commonly accepted that the EMC limits   
      have already taken common good laboratory practice. 
 
4.3 Final Decision 
       
      The equipment under test complies to all requirements of the applied test standards.     
     
 
Anam Electronics Co., Ltd. 
                                    Page 7 of 15 
AVR135/230 
EMC Test Report
 
         
Reference No.:NK2EE903
 
5. Standards, Deviations and Results 
 
5.1 Applied Test Standards 
         
      The following standards have been applied: 
 
      ●EN 55020:2002+A1:2003 
        Electromagnetic immunity of broadcast receivers and associated equipment 
Phenomena Basic 
Standards 
Result
(S1)Input immunity to RF voltages 
EN 55020:2002+A1:2003 
N/A 
(S2a)Immunity to RF voltages 
EN 55020:2002+A1:2003 
N/A 
(S2b)Immunity to RF voltages(in common mode)
EN 55020:2002+A1:2003 
N/A 
(S3)Immunity to ambient electromagnetic fields 
EN 55020:2002+A1:2003 
N/A 
(S4)Screening effectiveness 
EN 55020:2002+A1:2003 
N/A 
Electrostatic Discharge   
EN 61000-4-2:1995+A1:1998+A2:2001 
Pass 
Electromagnetic Field, keyed carrier 
EN 61000-4-3:2002+A1:2002 
Pass 
Electric Fast Transients/Burst 
EN 61000-4-4:1995+A1:2001+A2:2001 
Pass 
 
5.2 Deviations And Evaluations 
         
●No recorded deviations to the applied standards. 
        ●No general evaluations made. 
 
Page of 127
Display