7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE
FREQUENCY RANGE 30MHz TO 1,000MHz
7.1. Operating environment
Temperature
: 3℃
Relative humidity : 40%
7.2. Test set-up and procedure
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒.
The level of the test signal, which was connected to the receiver through a
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
combining network, was set to give 70 ㏈㎶ at the input of the EUT.
The signal was an unmodulated carrier.
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic
frequencies was measured with the receiver tuned to a selected number of FM
sound broadcast channels. Disturbance voltage due to all other sources was
measured with the receiver tuned to the channel 98.3 ㎒ respectively.
7.3. Measurement uncertainty
Antenna terminal disturbance voltage, Quasi-peak detection: ±2.0 ㏈
The measurement uncertainty describes the overall uncertainty of the given
measured value during the operation of the EUT in the above-mentioned way.
7.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Spectrum monitor
R & S
EZM
862064/004
R & S
ESVP
861743/024
Measurement
receiver
receiver
R & S
ESCS30
847124/017
Signal Generator
Anritsu
MG3632A
MT79870
Combining network
Municom
MCL ZFSC-2-11
N
N
942604
Matching pad
(50~75Ω)
(50~75Ω)
R & S
RAM 358
837254/004
* R & S: Rohde & Schwarz
Reference No. : 54120503A Page 12
◀ Anam EMC Test Laboratory ▶
◀
Anam EMC Test Laboratory ▶
Reference No. 54120312E Page 13
7.5. Test protocols
Date: February 21, 2005
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
98.2
54.0
37.3
2
196.4
50.0
*
3
294.6
50.0
*
4
392.8
52.0
*
87.5 5 491.0
52.0 *
6
589.2
52.0
*
7
687.4
52.0
*
8
785.6
52.0
*
9
883.8
52.0
*
10
982.0
52.0 *
1
100.8
54.0
37.1
2
201.6
50.0
*
3
302.4
52.0
*
4
403.2
52.0
*
90.1 5 504.0
52.0 *
6
604.8
52.0
*
7
705.6
52.0
*
8
806.4
52.0
*
9
907.2
52.0
*
1
108.7
54.0
38.8
2
217.4
50.0
*
3
326.1
52.0
*
98.0 4 434.8
52.0 *
5
543.5
52.0
*
6
652.2
52.0
*
7
760.9
52.0
33.9
8
869.6
52.0
*
9
978.3
52.0
*
Reference No. : 54120503A Page 13
◀ Anam EMC Test Laboratory ▶
Antenna terminal disturbance voltage due to the local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
1
110.8
54.0
39.4
2
221.6
50.0
*
3
332.4
50.0
*
4
443.2
52.0
*
100.1 5 554.0
52.0 *
6
664.8
52.0
*
7
775.6
52.0
35.8
8
886.4
52.0
*
9
997.2
52.0
*
1
116.8
54.0
39.4
2
233.6
50.0
*
3
350.4
52.0
*
4
467.2
52.0
*
106.1 5 584.0
52.0 *
6
700.8
52.0
*
7
817.6
52.0
34.1
8
934.4
52.0
*
1
118.7
54.0
39.6
2
237.4
50.0
*
3
356.1
52.0
*
108.0 4 474.8
52.0 *
5
593.5
52.0
*
6
712.2
52.0
*
7
830.9
52.0
33.3
8
949.6
52.0
*
OTHERS
Antenna terminal disturbance voltage due to other source than local oscillator.
Channel Harmonic
Measured
freq. (㎒)
Limit(㏈㎶)
Disturbance
value(㏈㎶)
98.0 / 46.0 *
*: less than 30 ㏈㎶
Limit according to EN55013:2001
Reference No. : 54120503A Page 14
◀ Anam EMC Test Laboratory ▶
8. DISTURBANCE POWER
8.1. Operating environment
Temperature
: 3℃
Relative humidity : 45%
8.2. Test set-up and procedure
The EUT was placed on a non-metallic table of 0.8m height. At the side of the
EUT a non-metallic table of 6m length was placed to provide for movement of
the absorbing clamp. The absorbing clamp was applied successively to all leads
whose length was 25 ㎝ or longer, unscreened or screened. For the read, the
maximum measured value at each frequency which was obtained when the
absorbing clamp is moved along the lead was registered. No metallic object,
including a possible other unit of the EUT or any person, was closer to the lead
or unit than 0.8m. All screened and unscreened cables were measured with an
absorbing clamp, according to EN 55013, 5.6.
absorbing clamp, according to EN 55013, 5.6.
8.3. Measurement uncertainty
Radio interference power: ±2.0 ㏈
The Measurement uncertainty describes the overall uncertainty of the given
measured value during operation of the EUT in the above-mentioned way.
measured value during operation of the EUT in the above-mentioned way.
8.4. Test instrumentation
Equipment
Manufacturer
Type No.
Serial No.
Spectrum monitor
R & S
EZM
862064/004
R & S
ESVP
861743/024
Measurement
receiver
receiver
R & S
ESCS30
847124/017
Absorbing clamp
R & S
MDS 21
860846/006
Oscillator Kenwood
AG-203A
3090241
* R & S: Rohde & Schwarz
8.5. Test protocols
Date: February 27, 2005
The equipment does comply with the requirements.
Operating condition: The EUT continuously operated with audio frequency
of 1,000 ㎐ being supplied from the Oscillator.
An absorbing clamp was placed around all leads.
At each mode, the maximum value at each testing frequency and each output
lead was registered and attached as follows.
of 1,000 ㎐ being supplied from the Oscillator.
An absorbing clamp was placed around all leads.
At each mode, the maximum value at each testing frequency and each output
lead was registered and attached as follows.