DOWNLOAD Harman Kardon AVR 135 (serv.man2) Service Manual ↓ Size: 4.88 MB | Pages: 127 in PDF or view online for FREE

Model
AVR 135 (serv.man2)
Pages
127
Size
4.88 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-135-sm2.pdf
Date

Harman Kardon AVR 135 (serv.man2) EMC - CB Certificate ▷ View online

Reference No. : 54120503A                                                                                                                        Page 11
 
◀  Anam EMC Test Laboratory  ▶
 
 
7. ANTENNA TERMINAL DISTURBANCE VOLTAGE IN THE   
  FREQUENCY RANGE 30MHz TO 1,000MHz
 
 
  7.1. Operating environment 
Temperature 
: 3℃ 
Relative humidity  : 40% 
 
    7.2. Test set-up and procedure 
Measurements were performed in the frequency range 30 ㎒ to 1,000 ㎒. 
 
The level of the test signal, which was connected to the receiver through a 
combining network, was set to give 70 ㏈㎶  at the input of the EUT. 
The signal was an unmodulated carrier. 
Disturbance voltage due to the local oscillator, it’s fundamental and harmonic 
frequencies was measured with the receiver tuned to a selected number of FM 
sound broadcast channels. Disturbance voltage due to all other sources was 
measured with the receiver tuned to the channel 98.3 ㎒ respectively. 
 
   7.3. Measurement uncertainty 
 
Antenna terminal disturbance voltage, Quasi-peak detection:  ±2.0 ㏈ 
 
The measurement uncertainty describes the overall uncertainty of the given 
 
measured value during the operation of the EUT in the above-mentioned way. 
 
7.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Spectrum monitor 
R & S 
EZM 
862064/004 
R & S 
ESVP 
861743/024 
Measurement 
receiver 
R & S 
ESCS30 
847124/017 
Signal Generator 
Anritsu 
MG3632A 
MT79870 
Combining network 
Municom 
MCL ZFSC-2-11 
942604 
Matching pad 
(50~75Ω) 
R & S 
RAM 358 
837254/004 
* R & S: Rohde & Schwarz 
 
 
 
 
 
 
 
Reference No. : 54120503A                                                                                                                        Page 12
 
◀  Anam EMC Test Laboratory  ▶
 
  Anam EMC Test Laboratory  ▶ 
Reference No. 54120312E                                                                                        Page 13 
7.5. Test protocols 
 
Date: February 21, 2005 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
98.2 
54.0 
37.3 
 2 
196.4 
50.0 
 3 
294.6 
50.0 
 4 
392.8 
52.0 
87.5 5 491.0 
52.0 * 
 6 
589.2 
52.0 
 7 
687.4 
52.0 
 8 
785.6 
52.0 
 9 
883.8 
52.0 
 10 
982.0 
52.0 * 
 1 
100.8 
54.0 
37.1 
 2 
201.6 
50.0 
 3 
302.4 
52.0 
 4 
403.2 
52.0 
90.1 5 504.0 
52.0 * 
 6 
604.8 
52.0 
 7 
705.6 
52.0 
 8 
806.4 
52.0 
 9 
907.2 
52.0 
 1 
108.7 
54.0 
38.8 
 2 
217.4 
50.0 
 3 
326.1 
52.0 
98.0 4 434.8 
52.0 * 
 5 
543.5 
52.0 
 6 
652.2 
52.0 
 7 
760.9 
52.0 
33.9 
 8 
869.6 
52.0 
 9 
978.3 
52.0 
 
Reference No. : 54120503A                                                                                                                        Page 13
 
◀  Anam EMC Test Laboratory  ▶
 
 
 
Antenna terminal disturbance voltage due to the local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
 1 
110.8 
54.0 
39.4 
 2 
221.6 
50.0 
 3 
332.4 
50.0 
 4 
443.2 
52.0 
100.1 5 554.0 
52.0  * 
 6 
664.8 
52.0 
 7 
775.6 
52.0 
35.8 
 8 
886.4 
52.0 
 9 
997.2 
52.0 
 1 
116.8 
54.0 
39.4 
 2 
233.6 
50.0 
 3 
350.4 
52.0 
 4 
467.2 
52.0 
106.1 5 584.0 
52.0  * 
 6 
700.8 
52.0 
 7 
817.6 
52.0 
34.1 
 8 
934.4 
52.0 
 1 
118.7 
54.0 
39.6 
 2 
237.4 
50.0 
 3 
356.1 
52.0 
108.0 4 474.8 
52.0  * 
 5 
593.5 
52.0 
 6 
712.2 
52.0 
 7 
830.9 
52.0 
33.3 
 8 
949.6 
52.0 
 
 
OTHERS 
Antenna terminal disturbance voltage due to other source than local oscillator. 
Channel Harmonic 
Measured 
freq. (㎒) 
Limit(㏈㎶) 
Disturbance 
value(㏈㎶) 
98.0   / 46.0 * 
 
*: less than 30 ㏈㎶  
 
                                            Limit according to EN55013:2001 
Reference No. : 54120503A                                                                                                                        Page 14
 
◀  Anam EMC Test Laboratory  ▶
 
 
8. DISTURBANCE POWER 
8.1. Operating environment 
Temperature 
: 3℃ 
Relative humidity  : 45% 
 
      8.2. Test set-up and procedure 
 
The EUT was placed on a non-metallic table of 0.8m height. At the side of the 
 
EUT a non-metallic table of 6m length was placed to provide for movement of 
 
the absorbing clamp. The absorbing clamp was applied successively to all leads 
 
whose length was 25 ㎝  or longer, unscreened or screened. For the read, the 
 
maximum measured value at each frequency which was obtained when the 
 
absorbing clamp is moved along the lead was registered. No metallic object, 
 
including a possible other unit of the EUT or any person, was closer to the lead 
 
or unit than 0.8m. All screened and unscreened cables were measured with an 
absorbing clamp, according to EN 55013, 5.6. 
 
   8.3. Measurement uncertainty 
 
Radio interference power:  ±2.0 ㏈ 
 
The Measurement uncertainty describes the overall uncertainty of the given   
measured value during operation of the EUT in the above-mentioned way. 
 
   8.4. Test instrumentation 
Equipment 
Manufacturer 
Type No. 
Serial No. 
Spectrum monitor 
R & S 
EZM 
862064/004 
R & S 
ESVP 
861743/024 
Measurement 
receiver 
R & S 
ESCS30 
847124/017 
Absorbing clamp 
R & S 
MDS 21 
860846/006 
Oscillator Kenwood 
AG-203A 
3090241 
 
* R & S: Rohde & Schwarz 
 
8.5. Test protocols 
 
Date: February 27, 2005 
 
The equipment does comply with the requirements. 
 
Operating condition: The EUT continuously operated with audio frequency 
of 1,000 ㎐  being supplied from the Oscillator. 
An absorbing clamp was placed around all leads.   
At each mode, the maximum value at each testing frequency and each output 
lead was registered and attached as follows. 
 
Page of 127
Display