Harman Kardon AURA (serv.man8) EMC - CB Certificate ▷ View online

Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 17 of 45 
 
Project No.: 
ZJ00032797 
Probe: 
L1 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-8-14 
Temp./Hum.(%RH): 21/56%RH 
Time: 
15:03:43 
EUT: 
Wireless stereo Speaker 
 
 
Model: 
HARMAN KARDON AURA 
Test Result: 
Pass 
Note:  
Mode 4: Optical 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.1500 43.32 0.48 43.80 
65.99 
-22.19 
QP 
2 0.1500 30.52 0.48 31.00 
55.99 
-24.99  AVG 
3 0.3180 34.80 0.50 35.30 
59.76 
-24.46 
QP 
4 0.3180 27.30 0.50 27.80 
49.76 
-21.96  AVG 
5 0.5899 28.80 0.50 29.30 
56.00 
-26.70 
QP 
6 0.5899 21.40 0.50 21.90 
46.00 
-24.10  AVG 
7 9.1220 30.02 0.78 30.80 
60.00 
-29.20 
QP 
8 9.1220 24.02 0.78 24.80 
50.00 
-25.20  AVG 
9 17.9420 26.26  1.04  27.30 60.00 -32.70 
QP 
10 17.9420 18.76  1.04  19.80 50.00 -30.20 
AVG 
11 29.9060 30.09  1.21  31.30 60.00 -28.70 
QP 
12 29.9060 21.39  1.21  22.60 50.00 -27.40 
AVG 
 
 
 
 
 
 
 
 
 
 
 
 
 
Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 18 of 45 
 
Project No.: 
ZJ00032797 
Probe: 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-8-14 
Temp./Hum.(%RH): 21/56%RH 
Time: 
15:08:28 
EUT: 
Wireless stereo Speaker 
 
 
Model: 
HARMAN KARDON AURA 
Test Result: 
Pass 
Note:  
Mode 4: Optical 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.1499 43.32 0.48 43.80 
66.00 
-22.20 
QP 
2 0.1499 30.12 0.48 30.60 
56.00 
-25.40  AVG 
3 0.3140 35.20 0.50 35.70 
59.86 
-24.16 
QP 
4 0.3140 28.40 0.50 28.90 
49.86 
-20.96  AVG 
5 0.6020 28.81 0.49 29.30 
56.00 
-26.70 
QP 
6 0.6020 21.41 0.49 21.90 
46.00 
-24.10  AVG 
7 0.9780 28.14 0.46 28.60 
56.00 
-27.40 
QP 
8 0.9780 21.04 0.46 21.50 
46.00 
-24.50  AVG 
9 9.1339 28.72 0.78 29.50 
60.00 
-30.50 
QP 
10 9.1339 22.72  0.78  23.50 50.00 -26.50  AVG 
11 29.9100 29.39  1.21  30.60 60.00 -29.40 
QP 
12 29.9100 21.19  1.21  22.40 50.00 -27.60 
AVG 
 
 
 
 
 
 
 
 
 
 
 
Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 19 of 45 
4.2 DISTURBANCE POWER MEASUREMENT 
4.2.1 LIMITS 
FREQUENCY (MHz) 
dBpW
Quasi-peak(dBpW) 
Average(dBpW) 
30 ~ 300 
45 to 55  (a) 
35 to 45  (a) 
Note:  (a) Increasing linearly with the frequency. 
4.2.2 TEST PROCEDURES 
The appliance to be tested is placed on a non-metallic table at least 0,4 m from other metallic 
objects and the lead to be measured on is stretched in a straight line for a distance sufficient to 
accommodate the absorbing clamp, and to permit the necessary measuring adjustment of 
position for tuning. The clamp is placed around the lead so as to measure a quantity 
proportional to the disturbance power on the lead. 
The absorbing clamp is positioned for maximum indication at each test frequency: the clamp 
shall be moved along the lead until the maximum value is found between a position adjacent 
to the appliance and a distance of about a half-wavelength from it. 
The straight portion of the lead to be measured on should therefore be about 6 m long, this 
being equal to λ max/2 + 0,6 m in order to allow at any time the positioning of the absorbing 
clamp and a possible second clamp for additional isolation. Pre-testing is carried out in all 
operating modes to find the worst mode for the every test terminal. 
4.2.3 TEST SETUP 
 
 
Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 20 of 45 
4.2.4 TEST RESULTS 
Project No.: 
ZJ00032797 
 
 
Standard: 
DP EN55013 QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Power Clamp Test 
Date: 
2013-8-15 
Temp./Hum.(%RH): 21/56%RH 
Time: 
8:53:06 
EUT: 
Wireless stereo Speaker 
 
 
Model: 
HARMAN KARDON AURA 
Test Result: 
Pass 
Note:  
BT        AC input 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBpW) 
Factor(dB) 
(dBpW) 
(dBpW) 
(dB) 
 
1 31.8000 6.05  18.25 24.30 45.07 -20.77 
QP 
2 31.8000 -3.95  18.25 14.30 35.07 -20.77  AVG 
3 41.8800 8.43  15.97 24.40 45.44 -21.04 
QP 
4 41.8800 -0.27  15.97 15.70 35.44 -19.74  AVG 
5 44.7599 7.72  15.58 23.30 45.55 -22.25 
QP 
6 44.7599 -2.68  15.58 12.90 35.55 -22.65  AVG 
7 54.0400 5.12  14.88 20.00 45.89 -25.89 
QP 
8 54.0400 -3.08  14.88 11.80 35.89 -24.09  AVG 
9 65.8000 7.60  15.10 22.70 46.33 -23.63 
QP 
10 65.8000 -0.10  15.10  15.00 36.33 -21.33 
AVG 
11 67.7600 8.43  15.17  23.60 46.40 -22.80 
QP 
12 67.7600 1.83  15.17  17.00 36.40 -19.40 
AVG 
 
Page of 45