DOWNLOAD Harman Kardon AURA (serv.man8) Service Manual ↓ Size: 2.21 MB | Pages: 45 in PDF or view online for FREE

Model
AURA (serv.man8)
Pages
45
Size
2.21 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
aura-sm8.pdf
Date

Harman Kardon AURA (serv.man8) EMC - CB Certificate ▷ View online

Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 5 of 45 
2. GENERAL DESCRIPTION OF EUT 
2.1 APPLICANT 
Name: 
Harman International Industries, Incorporated 
Address: 
8500 Balboa Blvd, Northridge, CA 91329, United States 
2.2 MANUFACTURER 
Name: 
Harman International Industries, Incorporated 
Address: 
8500 Balboa Blvd, Northridge, CA 91329, United States 
2.3 BASIC DESCRIPTION OF EQUIPMENT UNDER TEST  
Equipment: 
Wireless stereo speaker 
Model No.: 
HARMAN KARDON AURA 
Trade Name: 
HARMAN/KARDON 
Power supply: 
AC Adapter: 
 
Adaptor input 100-240V~50/60Hz 1.5A Max output DC19V,3A   
Speaker input: DC 19V,3A 
Test Mode: 
Mode 1: Audio in (EUT is playing a 1KHz audio signal. EUT is connecting 
with mobile phone through an audio line.) 
Mode 2: WIFI 
Mode 3: BT (EUT is working on Bluetooth connection with mobile phone.) 
Mode 4: Optical (EUT is working on Optical connection with DVD) 
Mode 5: Standby 
Sample 
submitting way   :
 
■Provided by customer    □Sampling 
Note: / 
Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 6 of 45 
3. LABORATORY AND ACCREDITATIONS  
3.1 LABORATORY 
The tests and measurements in this report except Input Immunity was performed by EMC 
Laboratory of Guangzhou GRG Metrology and Test CO., LTD. 
         Add. 
  :    163 Pingyun Rd, West of Huangpu Ave, Guangzhou, 510656, P. R. China 
         Telephone:   +86-20-38699959, 38699960, 38699961 
Fax 
  :   +86-20-38695185 
Input Immunity was performed by CGEL, Guangzhou EMC Laboratory. 
3.2 ACCREDITATIONS 
Our laboratories are accredited and approved by the following approval agencies according to 
ISO/IEC 17025. 
 
USA 
FCC Listed Lab No. 688188 
China 
CNAS NO.L0446 
China 
DILAC No.DL175 
Canada 
Registration No.:8355A-1 
 
3.3 MEASUREMENT UNCERTAINTY 
Where relevant, the following measurement uncertainty levels have been estimated for tests 
performed on the EUT as specified in CISPR 16-4-2: 
Measurement 
Frequency 
Uncertainty 
Radiated 
Emission 
Horizontal 
30MHz~1000MHz 
4.2dB 
Vertical 
30MHz~1000MHz 
4.4dB 
Conducted Emission 
9kHz~30MHz 
3.1 dB 
This uncertainty represents an expanded uncertainty factor of k=2. 
 
Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 7 of 45 
3.4 TEST INSTRUMENTS 
Name of equipment 
Manufacturer 
Model 
Serial number 
Calibration due 
RE 
Biconical Log-periodic 
Antenna 
ETS.LINDGREN
3142C 00075971 2014-05-26 
Receiver R&S 
ESU40 
100106 
2014-01-24 
DISTURBANCE POWER 
Receiver R&S 
ESU40 
100106 
2014-01-24 
Absorbing clamp 
LIITHI 
MDS21 
3637 
2014-06-26 
CE 
EMI Receiver 
R&S 
ESCI 
100529 
2014-07-30 
L.I.S.N SCHWARZBECK
NSLK 
8127 
8127450  2014-08-05 
Disturbance voltage at the antenna terminals 
EMI Receiver 
R&S 
ESCI 
100529 
2014-07-30 
Signal generator 
Rohde & Schwarz
SML03 
103002 
2014-11-13 
ESD 
ESD Tester 
EMPEK 
ESD-2030A 
0230916N 
2014-12-14 
S2A&S3&S5 
TS9980 test system 
No. 
Test 
Equipment 
Manufacturer  Model No.
Serial 
No. 
Cal. Date 
Cal. Due 
date 
SEL0166 Shielding 
Room 
Changzhou 
Zhong Yu 
JB88 N/A  N/A 
N/A 
SEL0143 
Signal Generator 
9KHz~2.2GHz 
Rohde&Schwarz
SML02 103321
2013-01-10 2014-01-10
SEL0135 
Signal Generator 
9KHz~1.1GHz 
Rohde&Schwarz
SML01 103172
2013-01-22 2014-01-22
SEL0144 Power 
Meter Rohde&Schwarz
NRVS  101126
2013-01-15 2014-01-15
SEL0137  RF Level Meter  Rohde&Schwarz
URV35 
100242
2013-01-25  2014-01-25
SEL0145 RF 
Probe Rohde&Schwarz
URV5-Z7
100372
2013-01-04 
2014-01-04
SEL0136 Audio 
Analyzer Rohde&Schwarz
UPL 
101127
2013-01-25  2014-01-25
SEL0157 
RF-Amplifier 
150KHz~150M
Hz 
BONN Elektronik
BSA1515-
25 
045622
-09 
2013-01-15 2014-01-15
SEL0167 
Stripline Test 
Cell 
Erika Fiedler 
VDE0872
N/A 
N/A 
N/A 
SEL0159 
TV Test 
Rohde& Schwarz
SFM 
100142
2013-02-05  2014-02-05
Report No.: EM201300550-11                        Application No.:
 
ZJ00032797                   Page 8 of 45 
Transmitter 
SEL0138 
TV Generator 
Pal 
Rohde& 
Schwarz 
SGPF 100129
2013-01-28 
2014-01-28
SEL0140 
TV Generator 
Ntsc 
Rohde& 
Schwarz 
SGMF 100037
2013-01-29 
2014-01-29
SEL0139 
TV Generator 
Secam 
Rohde& 
Schwarz 
SGSF 100052
2013-02-01 
2014-02-01
SEL0142 
TV-Test 
Transmitter 
0.3MHz~3300M
Hz 
Rohde& 
Schwarz 
SFQ 100512
2013-02-05 
2014-02-05
SEL0141 
MPEG2 
Measurement 
Generator 
Rohde& 
Schwarz 
DVG 100307
2013-01-25 
2014-01-25
SEL0146 Matching 
Pad 
Rohde& 
Schwarz 
RAM 100394
N/A 
N/A 
SEL0148 Matching 
Pad 
Rohde& 
Schwarz 
RAM 100395
N/A 
N/A 
SEL0158 
Absorbing 
Clamp 
Rohde& 
Schwarz 
MDS21 100137
2013-01-25 2015-01-25
SEL0149 
Coupling Set 
Erika Fiedler 
RCo,RCi, 
MC,AC, 
LC 
N/A N/A  N/A 
SEL0150 
Filters 
Erika Fiedler 
Sr, LBS 
N/A 
N/A 
N/A 
SEL0151 
Matching 
Network 
Erika Fiedler 
MN, T1 
N/A 
N/A 
N/A 
3.5 MONITORING OF EUT FOR THE IMMUNITY TEST 
Visual: 
Monitored the Spectrum Analyzer for any unintentional responses and any external 
change by the eyes. 
Audio: 
Hear the sound from EUT by ear. 
Monitor the SINAD by the Audio Analyzer for the audio signal performance. 
Page of 45