Harman Kardon AURA (serv.man8) EMC - CB Certificate ▷ View online
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 33 of 45
5.5.2 TEST SETUP
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 34 of 45
5.5.3 TEST RESULTS
Test: Immunity Conducted Voltages S2a <active speaker>
Test Mode: Combi Device - Monitor: Headphones
Operating Mode: AUX S/N: 72.0 dB
Frequency: - AF Level: 102.0 mV
Interf. Signal: Headphones, 040913-00025-001, 9/4/2013, 2:35:10PM
Test Mode: Combi Device - Monitor: Headphones
Operating Mode: AUX S/N: 72.0 dB
Frequency: - AF Level: 102.0 mV
Interf. Signal: Headphones, 040913-00025-001, 9/4/2013, 2:35:10PM
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 35 of 45
Test: Immunity Conducted Voltages S2a <active speaker>
Test Mode: Combi Device - Monitor: Headphones
Operating Mode: AUX S/N: 71.0 dB
Frequency: - AF Level: 101.2 mV
Interf. Signal: Headphones, 040913-00024-001, 9/4/2013, 2:31:19PM
Test Mode: Combi Device - Monitor: Headphones
Operating Mode: AUX S/N: 71.0 dB
Frequency: - AF Level: 101.2 mV
Interf. Signal: Headphones, 040913-00024-001, 9/4/2013, 2:31:19PM
Report No.: EM201300550-11 Application No.:
ZJ00032797 Page 36 of 45
5.6 IMMUNITY TO AMBIENT ELECTROMAGNETIC FIELDS (S3)
5.6.1 TEST REQUIREMENT
Test Requirement:
EN 55020
Test Method:
EN 55020
Criterion Required:
A
Wanted Signal:
60dBuV 1KHz FM with 40KHz deviation at 98MHz for FM mode.
1KHz Test sine wave for AUX mode.
Unwanted Signal:
1KHz AM 80% AM at the frequency listed below.
Unwanted signal and immunity limit for FM tuner mode.
Unwanted signal and immunity limit for AUX mode.
Click on the first or last page to see other AURA (serv.man8) service manuals if exist.