Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc62-dcr-hc62e-sm4.pdf
Date

Sony DCR-HC62 / DCR-HC62E (serv.man4) Service Manual ▷ View online

6-32
DCR-HC62/HC62E_ADJ
NTSC model
PAL model
Fig. 6-1-15
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst
position
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst
position
6-33
DCR-HC62/HC62E_ADJ
12. Color Reproduction Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
Measurement Point
Video terminal of A/V R jack
(75 
Ω terminated)
Measuring Instrument
Vectorscope
Adjusting
remote
commander
Specified Value
All color
Data of page: 6,
luminance
address: 0C is
points should
“00”
settle within each
color
reproduction
frame.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2: Perform this along with the “Color Reproduction Adjust-
ment” successively.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Note 4: NTSC model: DCR-HC62
PAL model: DCR-HC62E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
perform “6. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “0
0”.
(Note 5)
4
6
D0
Set the following data, and
press PAUSE (Write) button
 7C: NTSC model
 82: PAL model
5
6
01
4D
Press PAUSE (Write) button.
(Note 6)
6
6
02
Check the data changes to
“01”.
7
6
0C
Check the data is “00”.
Note 5: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: Confirm that the Y signal level (A) is 90±5 IRE.
(Refer to Fig 6-1-16)
90
±5 IRE = 606.9 to 678.3 mV (NTSC)
90
±5 IRE = 595 to 665 mV (PAL)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Fig.6-1-16
A
White
6-34
DCR-HC62/HC62E_ADJ
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
79
Press PAUSE (Write) button
Check on the monitor TV (Underscanned mode)
Fig. 6-1-17
13. Picture Frame Setting (AWB Adjustment frame)
Subject
Clear chart (AWB Adjustment frame)
(1 m (PTB-450) or 40 cm (PTB-1450)
from the front of lens)
Measurement Point
Video terminal of  A/V R jack (75 
terminated)
Measuring Instrument
Monitor TV
Specified Value
Only the clear chart must be shot
(entire screen is white).
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS ................................................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Perform “10. Picture Frame
Setting (Color reproduction
adjustment frame)”.
2
By zooming in the color
reproduction adjustment
picture frame, set up the
picture frame in which the
color bar is shot on full
screen. (Refer to Fig. 6-1-17)
3
Remove the Color bar chart
from the pattern box.
4
Check that whole of the
screen is white.
5
0
03
18
6
1
Read XH data and XL data.
(Note 2)
7
0
03
22
8
1
Read YH data and YL data.
(Note 2)
9
0
03
00
10
In the following adjustment, if
the “AWB Adjustment frame”
is used, adjust the clear chart
to this position.
Color bar chart picture frame
Monitor TV picture frame
6-35
DCR-HC62/HC62E_ADJ
14. Auto White Balance Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart
(AWB Adjustment Frame) (Note 3)
Adjustment Page
6F
Adjustment Address
2E to 31, E8 to EB, 2A, 2B
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Perform “13. Picture Frame Setting (AWB Adjustment
Frame)” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not,  perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “00”.
(Note 4)
4
6
01
B5
Press PAUSE (Write) button.
(Note 5)
5
6
02
Check the data changes to
“01”.
Note 4: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: The adjustment data will be automatically input to page:
6F, address: 2E to 31, E8 to F3, 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Page of 74