6-32
DCR-HC62/HC62E_ADJ
NTSC model
PAL model
Fig. 6-1-15
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst
position
position
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst
position
position
6-33
DCR-HC62/HC62E_ADJ
12. Color Reproduction Check
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
adjustment frame)
Measurement Point
Video terminal of A/V R jack
(75
(75
Ω terminated)
Measuring Instrument
Vectorscope
Adjusting
remote
commander
remote
commander
Specified Value
All color
Data of page: 6,
luminance
address: 0C is
points should
“00”
settle within each
color
reproduction
frame.
color
reproduction
frame.
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2: Perform this along with the “Color Reproduction Adjust-
ment” successively.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Note 4: NTSC model: DCR-HC62
Note 4: NTSC model: DCR-HC62
PAL model: DCR-HC62E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
perform “6. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”
is “Color Reproduction
Adjustment Frame”. If not,
perform “6. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “0
0”.
(Note 5)
4
6
D0
Set the following data, and
press PAUSE (Write) button
7C: NTSC model
82: PAL model
press PAUSE (Write) button
7C: NTSC model
82: PAL model
5
6
01
4D
Press PAUSE (Write) button.
(Note 6)
(Note 6)
6
6
02
Check the data changes to
“01”.
“01”.
7
6
0C
Check the data is “00”.
Note 5: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: Confirm that the Y signal level (A) is 90±5 IRE.
(Refer to Fig 6-1-16)
90
90
±5 IRE = 606.9 to 678.3 mV (NTSC)
90
±5 IRE = 595 to 665 mV (PAL)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Fig.6-1-16
A
White
6-34
DCR-HC62/HC62E_ADJ
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
79
Press PAUSE (Write) button
Check on the monitor TV (Underscanned mode)
Fig. 6-1-17
13. Picture Frame Setting (AWB Adjustment frame)
Subject
Clear chart (AWB Adjustment frame)
(1 m (PTB-450) or 40 cm (PTB-1450)
from the front of lens)
(1 m (PTB-450) or 40 cm (PTB-1450)
from the front of lens)
Measurement Point
Video terminal of A/V R jack (75
Ω
terminated)
Measuring Instrument
Monitor TV
Specified Value
Only the clear chart must be shot
(entire screen is white).
(entire screen is white).
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: The right four digits of the page: 1 displayed data of the
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
XH or YH data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS ................................................................... MANUAL
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS ................................................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Perform “10. Picture Frame
Setting (Color reproduction
adjustment frame)”.
Setting (Color reproduction
adjustment frame)”.
2
By zooming in the color
reproduction adjustment
picture frame, set up the
picture frame in which the
color bar is shot on full
screen. (Refer to Fig. 6-1-17)
reproduction adjustment
picture frame, set up the
picture frame in which the
color bar is shot on full
screen. (Refer to Fig. 6-1-17)
3
Remove the Color bar chart
from the pattern box.
from the pattern box.
4
Check that whole of the
screen is white.
screen is white.
5
0
03
18
6
1
Read XH data and XL data.
(Note 2)
(Note 2)
7
0
03
22
8
1
Read YH data and YL data.
(Note 2)
(Note 2)
9
0
03
00
10
In the following adjustment, if
the “AWB Adjustment frame”
is used, adjust the clear chart
to this position.
the “AWB Adjustment frame”
is used, adjust the clear chart
to this position.
Color bar chart picture frame
Monitor TV picture frame
6-35
DCR-HC62/HC62E_ADJ
14. Auto White Balance Standard Data Input
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
mal coefficient of the light value.
Subject
Clear chart
(AWB Adjustment Frame) (Note 3)
(AWB Adjustment Frame) (Note 3)
Adjustment Page
6F
Adjustment Address
2E to 31, E8 to EB, 2A, 2B
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Perform “13. Picture Frame Setting (AWB Adjustment
Frame)” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “00”.
(Note 4)
(Note 4)
4
6
01
B5
Press PAUSE (Write) button.
(Note 5)
(Note 5)
5
6
02
Check the data changes to
“01”.
“01”.
Note 4: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: The adjustment data will be automatically input to page:
6F, address: 2E to 31, E8 to F3, 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
Click on the first or last page to see other DCR-HC62 / DCR-HC62E (serv.man4) service manuals if exist.