5-11
3-2.
INITIALIZATION OF C, D, E, F, 7, 8 PAGE
DATA
3-2-1.
INITIALIZATION OF C, D, 8 PAGE DATA
1. Initializing the C, D, 8 Page Data
Note 1:
If “Initializing the C, D, 8 Page Data” is performed, all data of the
C page, D page and 8 page will be initialized. (It is impossible to
initialize a single page.)
Note 2:
If the C, D, 8 page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, D, 8 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) LCD system adjustments
6) Battery end adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to FF
Adjusting page
8
Adjusting Address
00 to FF
Initializing Method:
 Order
Page Address Data
Procedure
1
0
01
01
Set the data
2
3
81
10
Set the data
3
3
80
0A
Set the data, and press the
PAUSE button.
4
3
80
Check that the data changes to
“1A”
5
Perform “Modification of C, D,
8 Page Data”.
2. Modification of C, D, 8 Page Data
If the C, D, 8 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, D, 8 Page data
 Order
Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the
PAUSE button.
Note:
If the following symptoms occur after completing of the
“Modification of C, D, 8 page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The battery end mark on the LCD screen is flashing.
2) The power is shut off so that unit cannot operate.
3. C  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”).
Address
Remark
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14 to 16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 2E
2F
30
31 to 45
46
47 to 4C
4D
4E to 85
86
87 to 88
89
8A to 91
92
EE
00
00
00
E0
25
25
25
25
25
3E
3E
CA
99
88
E3
A1
04
20
03
E0
EE
00
00
00
E0
25
25
25
25
25
3E
3E
CA
99
88
E3
A1
04
20
03
E0
Switching position adj.
Fixed data-1
REEL FG adj.
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo fine adj.
Fixed data-1
APC adj.
Fixed data-1
Fixed data-2
REEL FG adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
5-12
4. D  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”).
Address
Remark
Initial value
NTSC PAL
Table. 5-3-3.
Address
Remark
Initial value
NTSC PAL
93 to 99
9A
9B to A4
A5
A6
A7 to AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE to E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Emergency memory address
00 to 0F
10
11 to 12
13
14
15 to 19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28 to 2A
2B
2C
2D
2E
2F
30
31 to 42
43
44 to 47
48
49
4A to 4C
4D
4E
4F to 50
51
52
53
54
55 to 57
58
59
5A to 5B
5C
5D to 64
65
66
67
68
00
90
98
00
90
98
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Battery end adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
5-13
Address
Remark
Initial value
NTSC PAL
Table. 5-3-4.
69
6A to 83
84
85 to 86
87
88 to 8D
8E
8F
90 to 9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2 to B8
B9
BA
BB to C3
C4
C5
C6
C7 to FF
80
70
80
30
C0
80
80
50
80
70
80
30
C0
80
80
50
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD) (GV-D800/D800E)
VCO adj. (LCD) (GV-D800E)
V-COM adj. (LCD)
(GV-D800/D800E)
RGB AMP adj.(LCD)
(GV-D800/D800E)
Fixed data-1
COM AMP adj.( LCD)
(GV-D800/D800E)
White balance adj. (LCD)
(GV-D800/D800E)
Contrast adj. (LCD)
(GV-D800/D800E)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
5. 8  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”).
Address
Remark
Table. 5-3-5.
00 to 20
21
22
23
24 to 98
99
9A to A2
A3
A4 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
5-14
3-2-2.
INITIALIZATION OF E, F, 7 PAGE DATA
1. Initializing the E, F, 7 Page Data
Note1:
If “Initializing the E, F, 7 Page Data” is performed, all data of the
E page, F page and 7 page will be initialized. (It is impossible to
initialize a single page.)
Note2:
If the E, F, 7 page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 7 page data
2) Servo and RF system adjustments
3) Video system adjustments
4) IR transmitter adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
00
Set the following data.
55: GV-D200/D800 (NTSC)
51: GV-D200E/D800E (PAL)
3
6
01
Set the following data, and press
PAUSE button.
55: GV-D200/D800 (NTSC)
51: GV-D200E/D800E (PAL)
4
6
02
Check that the data changes to
“01”.
5
Perform “Modification of E, F, 7
Page Data”.
2. Modification of E, F, 7 Page Data
If the E, F, 7 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 7 Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the
PAUSE button.
3. F  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”).
Address
Remark
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D to 22
23
24
25
26
27 to 2B
2C
2D
2E
2F to 32
33
34 to 3A
3B
3C to 4C
4D
4F to 5D
5E
5F
60 to 61
62
63
64
65
66
67
68
69 to 7A
7B
7C
7D
7E
7F
80
81 to 8A
8B
8C to 93
00
00
00
00
00
00
00
00
00
00
00
00
8C
0A
00
83
40
69
64
A6
94
80
41
33
C7
00
00
00
00
00
00
00
00
00
00
00
00
8C
0A
00
83
40
65
72
A6
94
80
41
33
C7
Emergency memory address
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
27MHz origin osc. adj.
Fixed data-1
Fixed data-2
Fixed data-1
Hi8/Std8 switching position adj.
CAP FG duty adj.
Hi8/Std8 AFC fo adj.
Fixed data-1
Hi8/Std8 Y output level setting
Hi8/Std8 chroma output level setting
Fixed data-1
Hi8/Std8 1.5MHz deviation adj.
Hi8/Std8 1.7MHz deviation adj.
Hi8/Std8 AFM BPF adj.
IR video deviation adj.
IR audio deviation adj.
IR video carrier freq. adj.
Fixed data-1
Fixed data-2
Fixed data-1
Page of 127
Display

Click on the first or last page to see other GV-D200 service manuals if exist.