Sony GV-D1000 Service Manual ▷ View online

5-11
GV-D1000/D1000E
Table. 5-3-6.
Address
Remark
Initial value
86
87
88
89
8A to 91
92
93 to 99
9A
9B to A4
A5
A6
A7 to AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to BF
C0
C1
C2
C3 to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF to E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
08
00
46
01
01
00
00
00
Fixed data-2
(Modified data. Copy the data built in
 the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Serial No. input
Address
Remark
Initial value
F0 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Emergency memory address
5-12
GV-D1000/D1000E
4. D Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”).
Address
Remark
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14
15
16
17
18 to 19
1A
1B
1C
1D to 1E
1F
20
21
22 to 23
24
25
26
27
28
29
2A to 2C
2D
2E
2F
30
31
32
33 to 3B
3C
3D
3E to 3F
41
42
43
44 to 47
48
49
4A
4B
4C
4D
4E
4F
50
00
00
Test mode
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Address
Remark
Initial value
NTSC PAL
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F to 63
64
65
66
67
68
69 to 6A
6B
6C
6D
6E
6F
70 to 8D
8E
8F
90 to 91
92
93
94
95
96 to 98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
80
70
80
30
C0
80
80
50
80
70
80
30
C0
80
80
50
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj.(LCD)
Fixed data-2
COM AMP adj.(LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
5-13
GV-D1000/D1000E
Table. 5-3-7.
5. 8 Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)Fixed data-2: Modified data. (Refer to “2. Modification
of C, D, 8 Page Data”).
Table. 5-3-8.
Address
Remark
Initial value
NTSC PAL
AB
AC
AD
AE
AF
B0
B1
B2
B3 to B5
B6
B7
B8
B9 to BB
BC
BD to BF
C0
C1
C2
C3
C4 to D0
D1
D2 to D9
DA
DB to DD
DE
DF
E0 to EF
F0
F1
F2 to FF
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
00 to 20
21
22 to 32
33
34 to 52
53
54 to 8F
90
91 to 98
99
9A to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
5-14
GV-D1000/D1000E
3-2-3.
INITIALIZATION OF B PAGE DATA
Note1:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Note2:
“INITIALIZATION OF B PAGE DATA” should be carried out
upon completion of “INITIALIZATION OF C, D, 8 PAGE DATA”.
1. Initializing the B Page Data
Note:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
10
05
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
03
Set the data, and press PAUSE
button.
5
2
8F
02
Set the data, and press PAUSE
button.
6
2
8F
00
Set the data, and press PAUSE
button.
7
5
0E
00
Set the data.
8
5
01
F3
Set the data, and press PAUSE
button.
9
5
00
01
Set the data, and press PAUSE
button.
10
Wait for 3 sec.
11
5
0E
Check that the data is “01”.
12
5
02
01
Set the data, and press PAUSE
button.
13
5
01
FE
Set the data, and press PAUSE
button.
14
5
00
01
Set the data, and press PAUSE
button.
15
5
02
Check that the data.
When the data is “00”, proceed
to step 20.
When the data is “FF”, proceed
to step 16.
16
2
0E
00
Set the data, and press PAUSE
button.
17
5
01
FD
Set the data, and press PAUSE
button.
18
5
00
01
Set the data, and press PAUSE
button.
19
5
0E
Check that the data is “01”.
20
Perform “Modification of B Page
Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
0
01
01
Set the data, and press PAUSE
button.
2
D
10
05
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
03
Set the data, and press PAUSE
button.
5
2
8F
02
Set the data, and press PAUSE
button.
6
2
8F
00
Set the data, and press PAUSE
button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the video cassette
recorder may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
D
10
00
Set the data.
3
2
00
29
Set the data.
4
2
01
29
Set the data, and press PAUSE
button.
3. B Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page
Data”).
Table. 5-3-9.
Address
Remark
00 to FF
Fixed data-1
Page of 127
Display