5-19
GV-D1000/D1000E
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
Fig. 5-3-4.
4-2. AGC Center Level Adjustment (VC-275 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
before adjustments”
Measurement Point
Pin w; of CN933 (RF MON) (Note 1)
Ext. trigger: Pin qj of CN933 (SWP)
Ext. trigger: Pin qj of CN933 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The data of page: 3, address: 03 is
“00”
“00”
Note1:
Connect a 75
Ω resistor between Pin w; and Pin ql (GND) of
CN933.
75
75
Ω resistor (Parts code: 1-247-804-11)
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-4.)
signal is stable. (Fig. 5-3-4.)
5
3
01
23
Set the data, and press PAUSE
button.
button.
6
3
02
Check that the data is “00”.
7
3
03
Check that the data is “00”.
(Note2)
(Note2)
8
Perform “APC & AEQ
Adjustment”.
Adjustment”.
Note2:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors. (Take an appropriate remedial measures according to
the errors referring to the following table.)
has errors. (Take an appropriate remedial measures according to
the errors referring to the following table.)
Data
Contents of defect
20
Perform re-adjustment. (Note 3)
30
The machine is defective
40
Perform re-adjustment. (Note 3)
50
The machine is defective
Note3:
If this data is displayed twice successively, the machine is defective.
4-3. APC & AEQ Adjustment (VC-275 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
before adjustments”
Measurement Point
Pin w; of CN933 (RF MON) (Note 1)
Ext. trigger: Pin qj of CN933 (SWP)
Ext. trigger: Pin qj of CN933 (SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is
“00”
“00”
Note1:
Connect a 75
Ω resistor between Pin w; and Pin ql (GND) of
CN933.
75
75
Ω resistor (Parts code: 1-247-804-11)
Note2:
The “AGC Center Level Adjustment” must have already been
completed before starting this adjustment.
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before
adjustments”
“Preparations before
adjustments”
2
0
01
01
Set the data.
3
3
33
08
Set the data.
4
Confirm that the playback RF
signal is stable. (Fig. 5-3-5.)
signal is stable. (Fig. 5-3-5.)
5
3
01
07
Set the data, and press PAUSE
button.
button.
6
3
02
Check that the data changes
from “07” to “00” in about 20
seconds after pressing PAUSE
button.
from “07” to “00” in about 20
seconds after pressing PAUSE
button.
7
3
03
Check that the data is “00”.
(Note3)
(Note3)
8
Perform “Processing after
Completing Adjustments”.
Completing Adjustments”.
Note3:
If the data is other than “00”, adjustment has errors. Take an
appropriate remedial measures according to the errors referring to
the following table.
appropriate remedial measures according to the errors referring to
the following table.
Data
Contents of defect
20
Perform re-adjustment. (Note 4)
30
The machine is defective
50
Perform re-adjustment. (Note 4)
60
The machine is defective
80
The machine is defective
Note4:
If this data is displayed twice successively, the machine is defective.
Fig. 5-3-5.
6.7 msec
PB RF signal is stable
Pin
qj
Pin
w;
5-20
GV-D1000/D1000E
5. PLL f
0
& LPF f
0
Fine Adjustment (VC-275 board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Data of page: 3, address: 03 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
30
Set the data, and press PAUSE
button.
button.
3
3
02
Check that the data changes to
“00” with in 5 sec. (Note1)
“00” with in 5 sec. (Note1)
4
3
03
Check that the data is “00”.
(Note2)
(Note2)
5
0
01
00
Set the data.
Note1:
If it isn’t satisfied, there are errors.
Note2:
If the data of page: 3, address: 03 is other than “00”, there are
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
Bit value of page: 3,
Error contents
address: 03 data
bit 2 = 1 or bit 3 = 1
PLL f
0
fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
adjustment is defective
bit 6 = 1
LPF f
0
adjustment is defective
4-4. Processing after Completing Adjustments
Order Page Address Data
Procedure
1
2
30
00
Set the data.
2
3
33
00
Set the data.
3
0
01
00
Set the data.
5-21
GV-D1000/D1000E
3-5.
VIDEO SYSTEM ADJUSTMENTS
1. 40.5MHz/54MHz Origin Oscillation Adjustment
(MS-95 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Mode
VTR stop
Signal
Not required
Measurement Point
Pin 8 of IC3302 on VC-275 board
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
f=13500000
± 68Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
12
Change the data and set the
frequency (f) to the specified
value.
frequency (f) to the specified
value.
3
F
12
Set the data, and press PAUSE
button.
button.
4
0
01
00
Set the data.
2. Chroma BPF fo Adjustment (VC-275 board)
Set the center frequency of IC3701 chroma band-pass filter.
Mode
VTR stop
Signal
No signal
Measurement Point
CH1: Chroma signal terminal of S
VIDEO OUT jack (75
VIDEO OUT jack (75
Ω terminated)
CH2: Y signal terminal of S VIDEO
OUT jack (75
OUT jack (75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
28
Specified Value
A = 100mVp-p or less
B = 200mVp-p or more
B = 200mVp-p or more
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Check that the burst signal (B) is
output to the chroma signal
terminal of S VIDEO OUT jack.
output to the chroma signal
terminal of S VIDEO OUT jack.
3
3
0C
04
Set the data, and press PAUSE
button.
button.
4
C
28
Change the data for minimum
amplitude of the burst signal
level (A).
(The data should be “00” to
“0F”.)
amplitude of the burst signal
level (A).
(The data should be “00” to
“0F”.)
5
C
28
Press PAUSE button.
6
3
0C
00
Set the data, and press PAUSE
button.
button.
7
Check that the burst signal level
(B) satisfies the specified value.
(B) satisfies the specified value.
8
0
01
00
Set the data.
Fig. 5-3-7.
CH1
CH2
A
H
CH1
H
B
When the data of page: 3, address: 0C, is 04:
When the data of page: 3, address: 0C, is 00:
Fig. 5-3-6.
1
20
10
11
IC3302
VC-275 board
5-22
GV-D1000/D1000E
3. S VIDEO OUT Y Level Adjustment (VC-275 board)
Mode
VTR stop
Signal
No signal
Measurement Point
Y signal terminal of S VIDEO OUT
jack (75
jack (75
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 ± 14mV
Switch setting:
DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
10
06
Set the data, and press PAUSE
button.
button.
3
D
11
10
Set the data, and press PAUSE
button.
button.
4
3
0C
02
Set the data, and press PAUSE
button.
button.
5
C
25
Change the data and set the Y
signal level (A) to the specified
value.
signal level (A) to the specified
value.
6
C
25
Press PAUSE button.
7
3
0C
00
Set the data, and press PAUSE
button.
button.
8
8
10
00
Set the data, and press PAUSE
button.
button.
9
D
11
00
Set the data, and press PAUSE
button.
button.
10
0
01
00
Set the data.
Fig. 5-3-8.
4. S VIDEO OUT Chroma Level Adjustment
(VC-275 board)
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
OUT jack (75
OUT jack (75
Ω terminated)
External trigger: Y signal terminal of
S VIDEO OUT jack
S VIDEO OUT jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level:
A = 714 ± 14mV (NTSC)
A = 700 ± 14mV (PAL)
A = 700 ± 14mV (PAL)
Cb level:
B = 714 ± 14mV (NTSC)
B = 700 ± 14mV (PAL)
B = 700 ± 14mV (PAL)
Burst level: C = 286 ± 6mV (NTSC)
C = 300 ± 6mV (PAL)
Switch setting:
DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
10
06
Set the data, and press PAUSE button.
3
D
11
10
Set the data, and press PAUSE button.
4
3
0C
02
Set the data, and press PAUSE button.
5
C
26
Change the data and set the Cr signal
level (A) to the specified value.
level (A) to the specified value.
6
C
26
Press PAUSE button.
7
C
27
Change the data and set the Cb signal
level (B) to the specified value.
level (B) to the specified value.
8
C
27
Press PAUSE button.
9
Check that the burst signal level
(C) is satisfied the specified value.
(C) is satisfied the specified value.
10
3
0C
00
Set the data, and press PAUSE button.
11
8
10
00
Set the data, and press PAUSE button.
12
D
11
00
Set the data, and press PAUSE button.
13
0
01
00
Set the data.
Fig. 5-3-9.
H
Center of luminance line
A
H
C
A
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)
B
0.28
µ
sec (NTSC)
0.23
µ
sec (PAL)