XBR-43X830C, 49X830C, 835C, 837C, 839C 
97 
TROUBLE SHOOTING 
3-3-4. 3 Times Blinking (HDMI EQ Error) 
3-time blinking 
IC5212 
BMFL/BMFW board 
Check  
VS GND impedance 
of +1.0V_HDMI 
at HDMI EQ side  
(ex.C5335) 
NG 
Check  
VS GND impedance 
of EQ_+3.3V_MAIN 
at HDMI EQ side  
(ex.C5317) 
NG 
OK 
OK 
IC5212 
Check  
VS GND impedance 
of +5V_BOSTON 
at HDMI EQ side  
(ex.C5351) 
NG 
IC5212 
OK 
Check  
Voltage 
of +1.0V_HDMI, 
EQ_+3.3V_MAIN, 
+5V_BOSTON 
at HDMI EQ side  
(ex.C5335, C5317, 
and C5351, ) 
NG 
Power, 
DDCON 
OK 
Check  
Frequency of X’tal  
(X5202)  
27MHz? 
NG 
X’tal or 
around parts. 
X5202,  
R5478(100ohm), 
R5368(1Mohm) 
C5298(10pF) 
C5297(12pF) 
OK 
Check  
I2C_C bus signal. 
at CL5259 and 
CL5261. 
NG 
IC5212 
Or IC1000 
OK 
IC1000 
This 3 times blinking function  for HDMI EQ 
error has been disabled  for  the SW later 
than PKG2173.  
So, for the  above applicable models, you 
can Ignore this flow. 
 
For those models  with  the SW before  
PKG2073.  
This  3 times blinking function  for HDMI 
EQ error has been enabled except for the 
sets with the SW updated by OTA. 
XBR-43X830C, 49X830C, 835C, 837C, 839C 
98 
TROUBLE SHOOTING 
3-3-5. 5 Times Blinking (Panel Communication Error) 
5-times blinking 
Check  
“+12.5V_TCON” at 
CN9000
 
 
on the B-Board 
Replace the Harness  
Between G-Board  
and B-Board 
Replace 
 the V-By-One FFC 
Change 
B-Board 
Change  
Panel (T-con) 
Harness is 
 suspicious 
V-By-One FFC 
is suspicious 
B-Board is 
 suspicious 
NG 
OK 
NG 
Symptom  
improvement 
Symptom  
improve 
Symptom  
improve 
NG 
NG 
G-Board is 
suspicious 
Replace G-Board 
NG 
Panel (T-Con) is 
 suspicious 
Symptom  
improvement 
OK 
XBR-43X830C, 49X830C, 835C, 837C, 839C 
99 
TROUBLE SHOOTING 
3-3-6. 6 Times Blinking (Backlight Error) 
Harness / 
Connection 
 broken 
6-times blinking 
Check  a voltage of 
BL_ERR_DET. 
Check point is 
JL9007 
or 
23pin of CN9000 
on B*Board 
Voltage ≥ 1.9 V 
Symptom 
Improvement 
Harness 
Change  
harness 
Change  
B* board 
B* Board 
Harness / 
Connection OK 
No improvement 
Voltage < 1.8 V 
Panel 
Change  
Panel 
Symptom  
Improvement 
No Improvement 
Symptom  
Improvement 
LED driver or G* board 
 Change LD board or G* board. 
No improvement 
LD board/G board 
Symptom  
Improvement 
Check  
harness/connection 
 G*board to B*Board 
or  
LD board to B*Board 
XBR-43X830C, 49X830C, 835C, 837C, 839C 
100 
TROUBLE SHOOTING 
3-3-7. 7 Times Blinking (Temperature Error) 
7-time blinking 
B* Board NG 
Yes 
Panel 
NG 
Change B* Board, 
and Aging a few  
hours 
Setting  
circumstance is OK? 
Temperature,  
Ventilation, etc. 
Set to another 
location, etc. 
No 
Symptom  
improvement 
Check I2C_C bus  
communication OK? 
(check the next page) 
Yes 
No 
Temp sensor  
IC1400 
I2C_C bus dumping or  
Muffin check 
Page of 127