– 4 –
KV-SW213M81
   RM-GA002
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 32 of IC001 (A board).
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go to
standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 13 of IC001
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will be
detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture will be
detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA1
V.GUARD
SDA
5
F.B-PLS
3
13
84
32
122
A BOARD
FROM
Q816
COLLECTOR
99
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
4. SELF DIAGNOSTIC SCREEN DISPLAY
5. HANDLING SELF DIAGNOSTIC SCREEN DISPLAY
6. SELF-DIAGNOSTIC CIRCUIT
2 OCP
: 0
3 OVP
: N/A
4 VSTOP : 1
5 AKB
: 0
8 SVP
: 0
101 WDT : N/A
"0" means no fault has been detected.
"1" means a fault has been detected.
"N/A" means not available for this models.
SELF DIAGNOSTIC
5
8
No.
Description
Method
1.
Display self diagnostic screen
[Display] t [Channel    ] t [Volume    ] t [Power / TV]
Note: The above must be performed while TV is on standby mode.
2.
Stop standby flash
i) Turn off power switch on main.
ii) Unplug power cord from the outlet.
3.
Clear fault result
In self diagnostic screen,press
[Channel    ] t 
-
Note: Diagnostic results display on screen is not automatically cleared. Therefore,
clear result after completion of repair.
4.
Quit self diagnostic screen
Turn off power switch of remote commander or main unit.
– 5 –
KV-SW213M81
   RM-GA002
SECTION 1
DISASSEMBLY
1-3.
CHASSIS ASSY REMOVAL
1-5.
TERMINAL BRACKET
1-4.
 SERVICE POSITION
1-1.
REAR COVER REMOVAL
Two screws
     (WH.DIA.16) 
     (+P4 x16)
Terminal bracket
One screw
(+
BVTP
 
3
 × 
12
)
2  
One screw
     (
+BVTP
 
4
 
×
 
16
)
4  
Two screws
     (
+BVTP
 
3
 × 
12
)
5  
J Board
  (
Not used for this model
)
1-2.
SPEAKER REMOVAL
1  
Eight screws
     (+BVTP 4 × 16)
Rear cover
1-6.
 A BOARD REMOVAL
A Board
– 6 –
KV-SW213M81
   RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow a.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
c.
HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
A
A
B
B
C
 Anode Button
1-7.
PICTURE TUBE  REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
qs
Screw, Tapping 5 + Crown Washer (x4) 
4
 
Anode Cap Removal
9
 
Degaussing Coil
6
 
Loosen the Neck Assembly 
fixing screw and remove
Neck Assy
7
Loosen the Deflection Yoke
fixing screw and remove
5
 
C Board Removal
qa
 
Spring Extension
Removal (x2)
8
 
Holder, HV cable 
combi (x1)
0
 
Earth Coating Assy
– 7 –
KV-SW213M81
   RM-GA002
SECTION 2
WIRE DRESSING
CAUTION :
1.  Do not overpull the wires during dressing
--> avoid disconnection of wires.
2.  Make sure wires are kept away from
sharp edges, heatsinks & other
high-temperature parts.
2-1.  Mount Caution on A/C board
2-2.  Connector Assy, 5P (YUV wire) dressing
A
CN801
Mounted Wire (DIP)
Plug (A/I)
C
W068
W069
R828
R829
R889
UL wire
P/N 1-923-082-52
Ensure UL wire does not touch high
temperature resistors R828, R829 & R889
W052
Lead Assy, Jumper
Conn Assy, 5P (YUV)
Make sure the UL tape is
positioned
at the sharp edge of
shield case to
prevent wire from being
scratched
Connector Assy, 5P & Lead Assy, 
Jumper go around shield case &
dress with pin wire A021
R121
Lead Assy, G2 & 200V wire on C Board UL wire P/N 1-923-082-52 on A Board (W068-W069)
CAUTION:
Dress & control mounted wires (Lead Assy, G2 & 200V wire) on C  board
if necessary :
--> ensure wires do not get trapped during solder dip process
--> ensure wires do not get punched by ICT jig (modify ICT jig if applicable)
CAUTION:
1) Make sure wires are kept
away from sharp edges &
heatsinks
2) Keep UL wire close to
board surface
3) Make sure wires are kept
away from high-temperature
parts
4) Ensure wires do not get
punched by ICT jig (modify
ICT jig if applicable)
CN703:
Ensure Pin 
1 is 
connected
to orange
wire 
(200V)
W700:
Board-
in Lead
Assy, 
G2
W051
Keep UL wire close to
board surface --> vertical
seam improvement
Make sure Conn Assy, 5P
does not touch resistor, R121
Keep Lead Assy, Jumper
away from shield case -->
C/M for OSD drift from RF to
Video mode
Make sure the Connector Assy,
5P is kept close to board surface.
CAUTION:
1) Dress Lead Assy, Jumper according to the green route.
  => Ensure Lead Assy, Jumper is dress away from shield case in the boxed area.
  => Ensure Lead Assy, Jumper is dress below Conn Assy, 5P (YUV).
2) Make sure wires are kept away from sharp edges, heatsinks & other high-temperature parts