– 12 –
KV-SW213M81
   RM-GA002
2-11.  Lead Assy, G2 and Lead Assy, Focus dressing
2-12.  Conn Assy, 7P, Connector Assy, 3P, Lead Assy, Earth & Rotational Coil Conn dressing
Purse Lock Ø5
Use this as a
reference to
dress ECA,
Lead Assy,
Focus & G2
 
Lead Assy, Focus
Conn. Assy, 5P (200V)
Earth Assy, Coating
Lead
Assy,
G2
Purse Lock Ø5
HV Cable
Keep Lead Assy,
G2 away from HV
Cable 
(as least 1mm/kv)
Keep Lead Assy,
G2 away from
Heat Sink.
Lead Assy, G2
Lead Assy,
G2
Lead Assy,
Focus
Earth Assy,
Coating
Purse Lock Ø5
3D models 
Purse Lock Ø9
Lead Assy, Earth
Conn Assy, 7P
Keep wires away
from heat sinks
UL Wire (1-923-000-81)
Conn Assy, 3P 
Rotational Coil Conn 
Non 3D models
Purse Lock Ø5
Conn Assy, 7P
Rotational Coil Conn
Lead Assy, Earth
UL Wire (1-923-000-81)
Lead Assy, Earth
Connector Assy, 7P
 UL Wire
Rotational Coil Conn.
Conn Assy, 3P
DY
90
o
Wire from
Rotation Coil
Connector Assy, 7P
Lead Assy, Earth
  UL Wire
Lead Assy, Focus & Lead Assy, G2 is pulled straight up
from FBT to Earth Assy, Coating & dressed together with
purse lock Ø5
TVSR (Clause 9.4.7) :
- Keep HV cables away from
  conductive parts 1mm/KV or more
CAUTION:
1. Do not overpull the wires during dressing -->
avoid disconnection of wires.
2. Make sure wires are kept away from sharp
edges, heatsinks & other high-temperature parts.
Keep wires away
from heat sinks
UL Tape
UL Tape
Purse Lock Ø9
Purse Lock Ø5
Rotational Coil Conn
CAUTION:
1. Do not overpull the wires during dressing --> avoid
disconnection of wires.
2. Make sure wires are kept away from
sharp edges, heatsinks & other high-temperature parts.
Rotation Coil
– 13 –
KV-SW213M81
   RM-GA002
2-13.  HV Lead Assy dressing
2-14.  AC Power Cord Dressing
180 ± 5 mm
HV Holder Combi
HV Holder Combi
Purse Lock Ø9 
HV Holder Combi 
Dress HV Holder
Combi with Purse
Lock Ø9 as shown
Fix the bigger diameter hook of HV
Holder Combi on the right side of
black tape & at horizontal bending
of DGC, then use purse lock Ø9 to
secure HV Holder Combi to DGC
SAFETY OPERATION
45º
B
A
A
A
C
DGC
Purse Lock Ø9
PWB Bracket hook 
Dress AC Power Cord at PWB Bracket hook as shown.
Terminal Bracket 
AC Cord Holder
AC Power Cord
 Dress AC Cord Holder at the terminal bracket. 
DGC
Conn
outlet
Black tape
Place purse lock Ø9 after the
exit of DGC conn from DGC
TVSR (Clause 9.4.7):
A) Spacing between HV cable and
conductive part's surface --1mm/kV
or more
B) Spacing between edge of anode
cap and conductive parts -->
0.5mm/kV or more
C) Spacing between HV cable &
enclosure with ventilation (i.e. Rear
Cover side) --> 10mm or more
CAUTION:
Keep HV cable facing inwards DY to keep HV cable away from
ventilation side of rear cover --> 10mm or more.
Ensure TVSR 1mm/kV is kept from HV cable to DY & other
conductive parts
– 14 –
KV-SW213M81
   RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture control ......................................................... NORMAL
Brightness control ................................................... NORMAL
Perform the adjustments in order as follows:
1. Beam Landing
2. Convergence
3. Focus
4. G2 (SCREEN)
5. White Balance
Note: Test Equipment Required
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
SECTION 3
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's
picture tube, face it east or west.
3-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loosen the deflection yoke mounting screw, and set the
purity control to the center as shown below.
3. Set the raster signal of the pattern generator to green.
4. Move the deflection yoke (DY) backward and adjust the
purity control so that green is in the center and blue and
red are at the sides evenly.
5. Then move the DY forward and adjust so that the entire
screen becomes green.
6. Now switch over raster signal to red then blue and
confirm the condition.
...................................................................................................................................................................................................................... ...........
5. Oscilloscope
6. Landing Checker
7. XCV Adjuster
Purity control
Red
Blue
Green
7. When the position of the DY is determined, tighten it
with the DY mounting screw.
8. If the beam does not land correctly in all corners of the
screen, use magnet disc to correct it.
3-2. CONVERGENCE ADJUSTMENT
Preparation :
• Before starting, perform FOCUS adjustment.
• Picture mode STANDARD.
• Receive dot/cross hatch pattern.
a) Vertical Static Convergence
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
a
b
b
c
c
d
d
a
Center dot
R    G    B
R
G
B
4 pole magnet
C/CV Board
– 15 –
KV-SW213M81
   RM-GA002
1. (Moving vertically), adjust the 4 pole magnet to converge
red, green and blue dots in the center of the screen.
2. Tilt the 4 pole magnet and adjust static convergence to
open or close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of
arrow A and B, the red, green and blue dots moves as
shown below:
b) Horizontal Static Convergence
If the blue dots does not converge with the red and green
dots, use the 6 pole magnet to adjust in the manner
described below.
R
R
G
G
B
B
A
B
B
A
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
6 Pole Magnet
4 Pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
c) Convergence Rough Adjustment
Preparation :
• Before starting this adjustment, adjust the horizontal
and vertical static convergence.
Input cross hatch pattern.
i)
TLH
Adjust the horizontal convergence of red and blue dots
by inserting TLH Correction Plate to the DY pocket (left
or right).
ii)
YCH
Adjust YCH to balance Y axis.
iii) TLV
Adjust the vertical convergence of red and blue dots.
iv) XCV
Adjust XCV to balance X-axis.
d) Screen Corner Convergence
Affix a Piece A (90), Convergence Correct/Permaloy Assy
Correction to the misconverged areas.
TLV
R B
YCH
R
B
XCV
B
R
TLH
B
R
TLV
ON DY:
TLV
XCV
YCH
DY pocket
DY pocket
TLH Plate
XCV
b
a
c
d
a-d : screen-corner
        misconvergence
a1~d1:Piece A (90), Convergence Correct
or
Permaloy Assy Correction
a1
b1
c1
d1
B
R
G
G
R
B
Page of 64