– 4 –
KV-LS212M50/M61/M81/N60
   RM-GA002
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 32 of IC001 (A board).
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go to
standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 13 of IC001
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will be
detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture will be
detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHT0
RED LED
DISPLAY
SDA1
V.GUARD
SDA
5
F.B-PLS
3
13
84
32
122
A BOARD
FROM
Q816
COLLECTOR
99
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
4. SELF DIAGNOSTIC SCREEN DISPLAY
5. HANDLING SELF DIAGNOSTIC SCREEN DISPLAY
6. SELF-DIAGNOSTIC CIRCUIT
2 : 
000
3 :
000
4 :
000
5 :
001
8 :
002
101 :
N/A
"0" means no fault has been detected.
"1" means a fault has been detected.
"2" means two faults have been detected.
"N/A" means not available for this models.
SELF DIAGNOSTIC
5
8
No.
Description
Method
1.
Display self diagnostic screen
[Display] t [Channel    ] t [Volume    ] t [Power / TV]
Note: The above must be performed while TV is on standby mode.
2.
Stop standby flash
i) Turn off power switch on main.
ii) Unplug power cord from the outlet.
3.
Clear fault result
[Channel    ] t 
-
Note: Diagnostic results display on screen is not automatically cleared. Therefore,
clear result after completion of repair.
4.
Quit self diagnostic screen
Turn off power switch of remote commander or main unit.
– 5 –
KV-LS212M50/M61/M81/N60
   RM-GA002
SECTION 1
DISASSEMBLY
1-3.
SERVICE POSITION
1-5.
H1 BOARD REMOVAL
1-4.
 A BOARD REMOVAL
1-1.
REAR COVER REMOVAL
1-2.
SPEAKER REMOVAL
1 Nine screws
     (+BVTP 4 x
 16
      Type2 IT-3)
2 Rear cover
2 Two screws
     (+PWTP2 4 x 16)
1 Two screws
     (+BVTP 4 x 16) 
A Board
  2 H1 Board
  1 Two screws
       (+BVTP 3 x 12)
– 6 –
KV-LS212M50/M61/M81/N60
   RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT.
REMOVING PROCEDURES
Turn up one side of the rubber cap in the direction
indicated by the arrow a.
Using a thumb pull up the rubber cap firmly in the direction
indicated by the arrow b.
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by turning
up the rubber cap and pulling it up in the direction of the
arrow 
c.
HOW TO HANDLE AN ANODE-CAP
Do not damage the surface of anode-caps with sharp
shaped objects.
Do not press the rubber too hard so as not to damage
the inside of anode-cap.
A metal fitting called the shatter-hook terminal is built
into the rubber.
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage the
rubber.
A
A
B
B
C
 Anode Button
1-6.
PICTURE TUBE  REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
9 Degaussing Coil
qa
 Spring Extension 
     Removal (x2)
8 Holder, DGC
     Removal (x2)
     (not used)
5 CV Board Removal
6 Loosen the Neck Assembly
     fixing screw and remove
     Neck Assy
q;
 Earth Coating Assy
4 Anode Cap Removal
qs
 Screw, Tapping 5+ Crown Washer (x4)
7 Loosen the Deflection Yoke
     fixing screw and remove
– 7 –
KV-LS212M50/M61/M81/N60
   RM-GA002
SECTION 2
WIRE DRESSING
CAUTION :
1. Make sure wires are kept away from sharp
edges, heatsinks & high temperature parts.
2. Do not over pull the wires during dressing
--> avoid disconnection of wires.
3. Prevent wires from being sandwiched with
beznet's front terminal when docking chassis.
4. Prevent tie, cable from touching rear cover
or any enclosures by turning them away
from it --> to avoid rattle sound & prevent
cable tie from touching solder side of board.
2-1.  Mount Caution on CV board
2-2.  Mount Caution on A board
CAUTION:
Dress & control mounted wires (Lead Assy, G2 & 200V wire) on CV board if necessary : 
--> ensure wires do not get trapped during solder DIP process 
--> ensure wires do not get punched by ICT jig (modify ICT jig if applicable)
Lead Assy, G2 & 200V wire on CV Board
A
C
CN801
Mounted Wire (DIP)
Plug (A/I)
CV
CV
CV
CV
CN703
CN703:
Ensure Pin 1 is 
connected to orange 
wire (200V)
W700:
Board-in Lead 
Assy, G2
CV
CV Board
Lead Assy, G2
R795/R760
Keep Lead Assy, G2 away from 
leg of conductive parts.
R781
CAUTION:
Ensure Lead Assy, G2 is kept away from leg of nearby 
conductive parts during solder DIP process
--> to ensure insulation of wire does not get melted when 
touching leg of part due to heat conduction from solder bath.
W068
W069
R828
R829
R889
Ensure UL wire does not touch high temperature 
resistors R828, R829 & R889
UL wire 
P/N 1-923-082-52
UL wire P/N 1-923-082-52 on A Board (W068-W069)
CAUTION:
1) Keep UL wire close to board surface.
2) Ensure wires do not get punched by ICT jig 
  (modify ICT jig if applicable)
W051
W052
Keep UL wire close to board 
surface --> vertical seam 
improvement
UL wire on A Board (W051-W052)