Sony KV-HW212M60 Service Manual ▷ View online
– 4 –
KV-HW212M60/M80/M80/H/M83/M83/H/P52
RM-W101
KV-HW212M81
RM-W100
STANDBY (
1
) indicator
2. DISPLAY OF
STANDBY (
1
)
INDICATOR
FLASH COUNT
3. STOPPING THE
STANDBY (
1
)
INDICATOR FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY (
1
)
indicator from flashing.
4. SELF-DIAGNOSTIC SCREEN DISPLAY
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes off" that cannot be confirmed,
it is possible to bring up past occurrences of failure on the screen for confirmation.
it is possible to bring up past occurrences of failure on the screen for confirmation.
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
Display
/
Channel
5
/
Volume
/
Power
/ TV
˘
Note that this differs from entering the service mode (volume
[+]
).
The following screen will be displayed indicating the error count.
Diagnostic Item
Flash Count*
+B overcurrent
2 times
V-Protect
4 times
IK (AKB)
5 times
Power Supply NG (+5V)
8 times
for Video processor
* One flash count is not used for self-diagnosis.
Lamp OFF 3 sec
Lamp ON 300ms
Lamp OFF 300ms
2 :
0
3 :
N/A
4 :
0
5 :
1
8 :
0
101 :
N/A
SELF DIAGNOSTIC
Numeral "0" means that no fault was detected.
Numeral "1" means the number of a fault occurrence (1 ~ 255).
Numeral "1" means the number of a fault occurrence (1 ~ 255).
– 5 –
KV-HW212M60/M80/M80/H/M83/M83/H/P52
RM-W101
KV-HW212M81
RM-W100
5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic
screen during repairs. When you have completed the repairs, clear the result display to "0".
screen during repairs. When you have completed the repairs, clear the result display to "0".
Unless the result display is cleared to "0", the self-diagnosis function will not be able to detect subsequent faults after
completion of the repairs.
completion of the repairs.
[Clearing the result display]
To clear the result display to "0", press buttons on the remote commander subsequent as shown below when the
self-diagnostic screen is being displayed.
To clear the result display to "0", press buttons on the remote commander subsequent as shown below when the
self-diagnostic screen is being displayed.
8
,
-
[Quitting Self-diagnostic screen]
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
6. SELF-DIAGNOSTIC CIRCUIT
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 32 of IC001 (A board).
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go
to standby.
If the voltage of pin 32 of IC001 (A board) is more than 4V, the unit will automatically go
to standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 13 of IC001
(A board).
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will
be detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
be detected by IC001 (A board). TV will stay on, but there will be 5 times LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture
will be detected. eg: IC602, IC604 go faulty.
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture
will be detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA1
V.GUARD
SDA
5
F.B-PLS
3
13
84
32
122
A BOARD
FROM
Q816
COLLECTOR
99
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
for VIDEO PROCESSOR
– 6 –
KV-HW212M60/M80/M80/H/M83/M83/H/P52
RM-W101
KV-HW212M81
RM-W100
2
Rear cover
1
3D Speaker box assy
(KV-HW212M83/M83/H only)
2
Rear cover
1
Eight screws
(BVTP 4
(BVTP 4
×
16
Type2 IT-3)
1
Four screws
(BVTP 4
(BVTP 4
×
16
Type2 IT3)
SECTION 1
DISASSEMBLY
1-2.
REAR COVER REMOVAL
1-3.
SPEAKER REMOVAL
1-4.
CHASSIS ASSY REMOVAL
1-5.
SERVICE POSITION
1-6.
TERMINAL BRACKET REMOVAL
2
Terminal
bracket
3
One screw
(+BVTP 4x16
(+BVTP 4x16
Type2 IT-3)
1
One screw
(+BVTP 3x16
Type2 IT-3)
Type2 IT-3)
1-1.
3D SPEAKER REMOVAL
– 7 –
KV-HW212M60/M80/M80/H/M83/M83/H/P52
RM-W101
KV-HW212M81
RM-W100
1
Two screws
(BVTP 3x12 Type2 IT-3)
(KV-HW212M83/M83/H only)
(KV-HW212M83/M83/H only)
1-9.
PICTURE TUBE REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom
right and left.
1) Place the TV set with the CRT face down on a cushion jig.
2) Remove the rear cover.
3) Unplug all under connecting leads from the Deflection Yoke, Degaussing Coil and CRT grounding strap.
2) Remove the rear cover.
3) Unplug all under connecting leads from the Deflection Yoke, Degaussing Coil and CRT grounding strap.
qs
Degaussing Coil
5
C Board Removal
8
Chassis Assy Removal
9
Support, CRT(2) Removal
6
Loosen the Neck Assembly
fixing screw and removal
4
Anode cap Removal
0
Holder, DGC(2)
Removal
qd
Earth Coating assy
qf
DGC(2) Removal
qa
Spring Tension (2)
Removal
qg
Screw(5) Tapping
7
Loosen the Deflection Yoke
fixing screw and remove
A Board
1-8.
A BOARD REMOVAL
1-7.
J BOARD REMOVAL
(3D MODELS ONLY)