DOWNLOAD Sony KV-HR36K90 Service Manual ↓ Size: 8.49 MB | Pages: 127 in PDF or view online for FREE

Model
KV-HR36K90
Pages
127
Size
8.49 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-hr36k90.pdf
Date

Sony KV-HR36K90 Service Manual ▷ View online

– 45 –
KV-HR36K90/HR36N90
RM-1012
RM-1011
OPM
*1
*2
No.
Name
00
APC
01
TSY
02
AFM
03
DBL
04
SSO
05
SCH
NTSC Only
06
SCA
NTSC Only
07
DMG
08
VSN
09
LBB
10
23P
11
DF
36
12
DQP
26
13
VLIM
50/60/ZM/WZ
14
TUT1
5
15
TUT2
5
16
TUT3
5
17
TUTW
5
18
3NR
19
SIG
TV/Video(HD/DVD)
20
NSIG
TV/Video(HD/DVD)
13
VLIM
15
15
15
15
No.
Name
RF
Video
19
SIG
0
5
20
NSIG
0
20
Wide V-Center Limit
Tune Wait Time Mode1 (Max) 30[ms] + 10[ms] * service_data
No-Signal Detect number of lock detect count.
No-Signal Detect number of unlock detect counter.
Tune Wait Time Mode2 (Max) 30[ms] + 10[ms] * service_data
Tune Wait Time Mode3 (Max) 30[ms] + 10[ms] * service_data
Tune Wait Time 6 point sense
3D-NR INIT (User Reset or Test Reset)
Disable Blueback function
Speed CH Search Selection
CH Selection for Shipping Condition
Functionality
Function
APC Switch
TV System Selection under searching with Auto TV System
Auto FM switch
ZOOM 60Hz
Cable/Air Selection for Shipping Condition
Signa-Detect
Functionality
Disable Menu-operation Guide
Enable Noise Reduction in Video Mode
Lower Blue Back Intensity
2/3 Pull Down Mode 0: Force OFF, 1: Auto
DF_PHA
DQP_PHA
Range
Standards
Remarks
No.
Functionality
Name
V-Center Limit
WIDEZOOM
50Hz
WIDEZOOM
60Hz
ZOOM 50Hz
1
2
1
0
1
1
1
0
0
0
1
*2
*2
*1
1
– 46 –
KV-HR36K90/HR36N90
RM-1012
RM-1011
OPB
No.
Name
00
OP0
60
52
Optional Bits 0
01
OP1
107
Optional Bits 1
02
OP2
Optional Bits 2
03
OP3
104
Optional Bits 3
04
OP4
Optional Bits 4
Remarks
Functionality
Range
Standards
Function
3
53
TAIWAN
KOREAN
52
43
119
8
SRV
No.
Name
00
COM
Service Command
Remarks
Functionality
Range
Standards
Function
– 47 –
KV-HR36K90/HR36N90
RM-1012
RM-1011
SECTION 4
SET-UP ADJUSTMENTS
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
These adjustments should be performed with rated power
supply voltage unless otherwise noted.
Controls and switches should be set as follows unless otherwise
noted:
PICTURE control ........................................................... normal
BRIGHTNESS control................................................... normal
Perform the adjustments in the following order :
1. Beam Landing
2. Convergence
3. Focus
4. White Balance
Note : Test Equipment Required.
1. Color-bar/Pattern Generator
2. Degausser
3. Oscilloscope
...................................................................................................................................................................
Preparation :
In order to reduce the influence of geomagnetism on the set’s
picture tube, face it east or west.
Switch on the set’s power and degauss with the degausser.
4-1. INITIALIZING SFC DATA
1. Set to the service mode.
2. Set to the coarse CONV and LAND adjustment mode.
3. Move the marker in the order as shown in the figure and set
its data to “0”.
Landing: 1 
t 2 t 3 t 4 t 5 t 6 t 7
Convergence: 1 
t 2 t 3 t 4 t 5
4-2. BEAM LANDING
1. Input a white signal with the pattern generator.
Contrast
Brightness
2. Position neck assy as shown in Fig4-1.
3. Set the pattern generator raster signal to a green raster.
4. Move the deflection yoke to the rear and adjust with the pu-
rity control so that the green is at the center and the blue and
the red take up equally sized areas on each side.
(See Figures 4-2 through 4-4.)
5. Move the deflection yoke forward and adjust so that the
entire screen is green. (See Figure 4-3.)
6. Switch the raster signal to blue, then to green and verify the
condition.
7. When the position of the deflection yoke has been decided,
fasten the deflection yoke with the screws and DY spacers.
normal
}
Neck assy
G2
G1
G3
Behind the G2 edge
Fig. 4-1
Move the marker with the buttons 
R ,r , T  and t on the
remote commander.”
Press “ENTER” to decide the position.
Change the data with the buttons 
R ,r , T  and t on the
remote commander.
– 48 –
KV-HR36K90/HR36N90
RM-1012
RM-1011
4-3. CONVERGENCE ADJUSTMENT
Preparation :
Before starting this adjustment, adjust the focus, horizontal
size and vertical size.
Set the Picture Mode to “STANDARD”.
Cross hatch / Dot pattern.
4-3-1. Horizontal and Vertical Static Convergence
1. (Moving horizontally), adjust the H.STAT control so that the
red, green and blue dots are on top of each other at the center
of the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the
red, green and blue dots are on top of each other at the center
of the screen.
3. If the H.STAT variable resistor cannot bring the red, green
and blue dots together at the center of the screen, adjust the
horizontal convergence with the H.STAT variable resistor and
the V.STAT magnet in the manner given below.
(In this case, the H.STAT variable resistor and the V.STAT
magnet influence each other, so be sure to perform adjust-
ments while tracking.)
Fig. 4-3
Red
Blue
Green
Fig. 4-4
Purity control
corrects this area.
Deflection yoke positioning
corrects these areas.
Fig. 4-2
Center dot
R    G    B
R
G
B
H. STAT VR
V. STAT
Magnet
RV9001
H. STAT
C Board
Page of 127
Display