– 12 –
KV-AZ213M61/M81/M83/N60
   RM-GA002
2-10.  Lead Assy, G2 and Lead Assy, Focus dressing
2-11.  Wiredressing on CV board
Note: Same wire dressing condition as current BX1S06 AZ 212
Note: Same wire dressing condition as current BX1S06 AZ 212
TVSR (Clause 9.4.7) :
-  Keep HV cables away from
  conductive parts 1mm/KV or more
Lead Assy, 
G2
Lead Assy, Focus
Conn. Assy, 5P (200V)
Earth Assy,
Coating
Use this as a
reference to
dress ECA,
Lead Assy,
Focus & G2
Keep Lead Assy, G2
away from Heat Sink.
Keep Lead
Assy, G2
away from
HV Cable
(at least
1mm/kV)
 
Lead Assy, Focus & Lead Assy, G2 is pulled straight up
from FBT to Earth Assy, Coating & dressed together with
purse lock Ø5
Lead Assy
G2
Lead Assy
Focus
Earth Assy
Coating
Purse Lock Ø5
Purse Lock Ø5
HV Cable
Lead Assy, G2
Dress VM
wires
with pin,
wire A006
RGB wire dressed with
cable tie at alignment hole 
A
Make sure wire is not in
direct contact with heatsink
Dress RGB
wire with
pin, wire
A702
Caution:
1. Prevent cable tie from touching
rear cover or any enclosures by
turning them away from it --> to
avoid rattle sound & prevent cable
tie from touching solder side of
board.
2. TVSR: Keep HV cable (Lead
Assy, Focus) away from DY, DGC
and other conductive parts
Purse Lock Ø5
– 13 –
KV-AZ213M61/M81/M83/N60
   RM-GA002
2-12.  Conn Assy, 7P, Lead Assy, Earth & Rotational Coil Conn dressing
2-13.  HV Cable Wire dressing
Note:* Wire dressing done after chassis fully docked unto beznet & speaker box (L)
 
& ( R ) are fully installed.
Note: Same wire dressing condition as BX1S06 AZ 212
Purse Lock Ø5
Conn Assy, 7P
Rotational Coil
Non-rotational Coil
Rotational Coil
Purse Lock Ø5
Keep Lead Assy,
Earth away from heat
Keep Lead Assy,
Earth away from
heat sinks
 
Lead Assy, Earth
Lead Assy, Earth
Conn Assy, 7P
Connector Assy, 7P
Lead Assy, Earth
UL Wire
Rotational Coil Conn.
Connector Assy, 7P
Lead Assy, Earth
UL Wire
UL Tape
UL Wire (1-923-000-81)
UL Wire (1-923-000-81)
HV Cable
Dress HV cable using the 2 purse locks
--> Make sure HV Cable is straight up from
FBT, to avoid all conductive parts.
 
CAUTION:
Do not overpull the HV Cable during
dressing
--> avoid disconnection of cable.
TVSR (Clause 9.4.7):
1) Spacing between HV cable and conductive part's
surface --> 1mm/kV or more
2) Spacing between edge of anode cap and
conductive parts --> 0.5mm/kV or more
Keep a distance of 0.5mm/kV 
or more --> TVSR: Spacing 
between edge of anode cap 
and conductive parts
Keep a distance of 1mm/kV or
more --> TVSR: Spacing between 
HV cable and conductive part's 
surface
Purse Lock 
Ø
5
Purse Lock 
Ø
5
90
o
DY
90
o
Wire from 
Rotation Coil
Rotation Coil
– 14 –
KV-AZ213M61/M81/M83/N60
   RM-GA002
2-14.  AC Power Cord Dressing
   
    
Note: Same wire dressing condition as current BX1S06 AZ 212
PWB Bracket hook
Dress AC Power Cord at PWB Bracket hook as shown
AC Power Cord
Terminal
Bracket
AC Cord
 Dress AC Cord Holder at the terminal bracket
– 15 –
KV-AZ213M61/M81/M83/N60
   RM-GA002
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
The controls and switch should be set as follows unless
otherwise noted:
Picture control ......................................................... NORMAL
Brightness control ................................................... NORMAL
Perform the adjustments in order as follows:
1. Beam Landing
2. Convergence
3. Focus
4. G2 (SCREEN)
5. White Balance
Note: Test Equipment Required
1. Pattern Generator
2. Degausser
3. DC Power Supply
4. Digital Multimeter
SECTION 3
SET-UP ADJUSTMENTS
Preparation :
• Feed in the white pattern signal.
• Before starting, degauss the entire screen with the
degausser.
• In order to reduce the geomagnetism on the set's
picture tube, face it east or west.
3-1. BEAM LANDING ADJUSTMENT
1. Input a raster signal with the pattern generator.
2. Loosen the deflection yoke mounting screw, and set the
purity control to the center as shown below.
3. Set the raster signal of the pattern generator to green.
4. Move the deflection yoke (DY) backward and adjust the
purity control so that green is in the center and blue and
red are at the sides evenly.
5. Then move the DY forward and adjust so that the entire
screen becomes green.
6. Now switch over raster signal to red then blue and
confirm the condition.
...................................................................................................................................................................................................................... ...........
5. Oscilloscope
6. Landing Checker
7. XCV Adjuster
Purity control
Red
Blue
Green
7. When the position of the DY is determined, tighten it
with the DY mounting screw.
8. If the beam does not land correctly in all corners of the
screen, use magnet disc to correct it.
3-2. CONVERGENCE ADJUSTMENT
Preparation :
• Before starting, perform FOCUS adjustment.
• Picture mode STANDARD.
• Receive dot/cross hatch pattern.
a) Vertical Static Convergence
a
b
b
c
c
d
d
a
Purity control
corrects this area.
Disc magnets or rotatable
disc magnets correct these
areas (a-d).
Deflection yoke positioning
corrects these areas.
4 pole magnet
RV750
H. STAT
RV1800
G2 (SCREEN) 
Center dot
R     G     B
G
R
B
Page of 70