DOWNLOAD Sony KV-AW212M50 Service Manual ↓ Size: 5.79 MB | Pages: 80 in PDF or view online for FREE

Model
KV-AW212M50
Pages
80
Size
5.79 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-aw212m50.pdf
Date

Sony KV-AW212M50 Service Manual ▷ View online

– 4 –
KV-AW212M50,M50/H,M63,M80,M80/H,M81,
M83,M83/H,N50,N60,N63/H,P50,P52
RM-GA002
[+B overcurrent $OCP%]
Occurs when an overcurrent on the +B(135V) line is detected by pin 43 of IC001 (A board).
If the voltage of pin 43 of IC001 (A board) is more than 4V, the unit will automatically go to
standby.
[V-PROTECT]
Occurs when an absence of the vertical deflection pulse is detected by pin 8 of IC001
(A board).
[IK $AKB%]
If the RGB levels* do not balance within 15 sec after the power is turned on, this error will be
detected by IC001 (A board). TV will stay on, no LED blinking.
Occurs when IC001 internal HV protect detects an abnormal H-Pulse (frequency) due to
improper power supply to IC001. TV cuts off high voltage power of anode CRT. No picture will be
detected. eg: IC602, IC604 go faulty.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
POWER SUPPLY NG (+5V)
for VIDEO PROCESSOR
4. SELF DIAGNOSTIC SCREEN DISPLAY
5. HANDLING SELF DIAGNOSTIC SCREEN DISPLAY
6. SELF-DIAGNOSTIC CIRCUIT
5
8
No.
Description
Method
1.
Display self diagnostic screen
[Display] t [Channel    ] t [Volume    ] t [Power / TV]
Note: The above must be performed while TV is on standby mode.
2.
Stop standby flash
i) Turn off power switch on main.
ii) Unplug power cord from the outlet.
3.
Clear fault result
[Channel    ] t 
-
Note: Diagnostic results display on screen is not automatically cleared. Therefore,
clear result after completion of repair.
4.
Quit self diagnostic screen
Turn off power switch of remote commander or main unit.
2 OCP 
:  0
3 OVP 
:
N/A
4 VSTOP  :
1
5 AKB 
:
0
8 SUP 
:
0
101 WDT :  N/A
"0" means no fault has been detected.
"1" means a fault has been detected.
"2" means two faults have been detected.
"N/A" means not available for this models.
SELF DIAGNOSTIC
A BOARD
IC001
Y/CHROMA JUNGLE
A BOARD
IC804
V.OUT
A BOARD
IC001
SYSTEM
A BOARD
IC003
MEMORY
FROM
C BOARD
IC751 PIN 5
IK
EHTO
RED LED
DISPLAY
SDA
V.GUARD
SDA
5
F.B-PLS
3
8
56
43
80
A BOARD
FROM
Q804
COLLECTOR
69
– 5 –
KV-AW212M50,M50/H,M63,M80,M80/H,M81,
M83,M83/H,N50,N60,N63/H,P50,P52
RM-GA002
SECTION 1
DISASSEMBLY
1-2.
REAR COVER REMOVAL
1-1.
3D SPEAKER REMOVAL
1-4.
CHASSIS ASSY REMOVAL
1-3.
SPEAKER REMOVAL
1-6.
A BOARD REMOVAL
1-5.
SERVICE POSITION
1
 3D Speaker
     box assy
2
 Rear cover
1
 Nine screws
     (+BVTP 4 x
 
16
      TYPE2 IT-3)
3
 Rear cover
2
 Two screws
     (+BVTP 3 x
 
12
      TYPE2 IT-3)
1
 Four screws
 
(+BVTP 3 x 12
      TYPE2 IT-3)
A Board
– 6 –
KV-AW212M50,M50/H,M63,M80,M80/H,M81,
M83,M83/H,N50,N60,N63/H,P50,P52
RM-GA002
1-9.
PICTURE TUBE  REMOVAL
Note:
• Please make sure the TV set is not in standing position before removing necessary CRT support located on bottom right
and left.
1) Remove the Rear Cover.
2) Unplug all interconnecting leads from the Deflection Yoke, Neck Assy, Degaussing Coils and CRT grounding strap. Remove
Chassis Assy.
3) Place the TV set with the CRT face down on a cushion (jig).
1-8.
H1 BOARD REMOVAL
1-7.
J BOARD REMOVAL
(KV-AW212M63, M83, M83/H, N63/H)
J Board
1
 One screw
     (+BVTP 4 x 12 TYPE2 IT-3)
2
 H1 Board
1
 Two screws
     (+BVTP 3 x 12 TYPE2 IT-3)
8
 Degaussing Coil
0
 Spring Tension 
     Removal (x2)
qa
 Support CRT removal
5
 C Board Removal
9
 Earth Coating Assy
4
 Anode Cap Removal
qs
 Screw Tapping 5 + Crown Washer
7
 Loosen the Deflection Yoke
     fixing screw and remove
6
 Loosen the Neck Assembly
     fixing screw and remove
     VM Coil
– 7 –
KV-AW212M50,M50/H,M63,M80,M80/H,M81,
M83,M83/H,N50,N60,N63/H,P50,P52
RM-GA002
• REMOVAL OF ANODE-CAP
Note:
• After removing the anode, short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield
or carbon paint on the CRT.
REMOVING PROCEDURES
1
Turn up one side of the rubber cap in the direction
indicated by the arrow 
A
.
2
Using a thumb pull up the rubber cap firmly in the
direction indicated by the arrow 
B
.
3
When one side of the rubber cap is separated from the
anode button,  the anode-cap can be removed by
turning up the rubber cap and pulling it up in the
direction of the arrow 
C
.
HOW TO HANDLE AN ANODE-CAP
1
Do not damage the surface of anode-caps with
sharp shaped objects.
2
Do not press the rubber too hard so as not to
damage the inside of anode-cap.
A metal fitting called the shatter-hook terminal is
built into the rubber.
3
Do not turn the foot of rubber over too hard.
The shatter-hook terminal will stick out or damage
the rubber.
A
A
B
B
C
 Anode Button
Page of 80
Display

Click on the first or last page to see other KV-AW212M50 service manuals if exist.