DOWNLOAD Sony KV-AR34M86 Service Manual ↓ Size: 9.33 MB | Pages: 89 in PDF or view online for FREE

Model
KV-AR34M86
Pages
89
Size
9.33 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-ar34m86.pdf
Date

Sony KV-AR34M86 Service Manual ▷ View online

– 5 –
KV-AR34M86
RM-993
2. DISPLAY OF STANDBY/TIMER LIGHT FLASH COUNT
3. STOPPING THE STANDBY/TIMER FLASH
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER lamp
from flashing.
4. SELF-DIAGNOSTIC SCREEN DIPLAY
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it
is possible to bring up past occurances of failure for confirmation on the screen:
[To Bring Up Screen Test]
In standby mode, press buttons on the remote commander sequentially in rapid succession as shown below:
[Screen display] / channel [5] / Sound volume [-] / Power ON
˘
Note that this differs from entering the service mode (mode volume  [+]).
Self-Diagnosis screen display
Diagnostic Item
Flash Count*
+B overcurrent/overvoltage
2 times
Vertical deflection stopped
White balance failure
5 times
* One flash count is not used for self-diagnostic.
2 times
5 times
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
Lamp OFF 3 sec.
002 : 000
003 : 000
004 : 000
005 : 001
101 : 000
SELF DIAGNOSTIC
Numeral "0" means that no fault has been detected.
Numeral "1" means a fault has been detected.
STANDBY/SLEEP lamp
– 6 –
KV-AR34M86
RM-993
5. HANDLING OF SELF-DIAGNOSTIC SCREEN DISPLAY
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen
during repairs. When you have completed the repairs, clear the result display to “0”.
Unless the result display is cleared to “0”, the self-diagnostic function will not be able to detect subsequent faults after
completion of the repairs.
[Clearing the result display]
To clear the result display to “0”, press buttons on the remote commander sequentially as shown below when the diagnostic
screen is being displayed.
Channel [8]
/ 0
[Quitting Self-diagnostic screen]
To quit the entire self-diagnostic screen, turn off the power switch on the remote commander or the main unit.
6. SELF-DIANOSTIC CIRCUIT
[+B overcurrent ªOCPº]
Occurs when an overcurrent on the +B(135) line is detected by Q604. If Q604 go to ON
and the voltage to pin 18 of IC301 should go down when V.SYNC is more than seven
verticals in a period, the unit will automatically turn off.
[Vertical deflection stopped]
Occurs when an absence of the vertical deflection pulse is detected by Q509 and IC001
shut down the power supply.
[Vertical deflection overcurrent]
Occurs when an overcurrent on V drive line is detected by Q507. Power supply will be
shut down when detect this by IC001.
[White balance failure]
If the RGB levels* do not balance or become low level within 5 seconds, this error will be
detected by IC301. TV will stay on, but there will be no picture.
* (Refers to the RGB levels of the AKB detection Ref pulse that detects IK.)
IC301
Y/CHROMA JUNGLE
FROM
CRT
[V] Q509/507
IC001
SYSTEM
IC003
MEMORY
IK-IN
MP/
PROTECT
O-LED
IO-8DAT
B-DAT
IO-SDAT
5
21
18
51
46
SDA 35
FROM
[+B] Q604 C6
45
– 7 –
KV-AR34M86
RM-993
1 Thirteen screws
     (+BVTP 4 
× 16)
2 Rear cover
SECTION 1
DISASSEMBLY
1-1.
REAR COVER REMOVAL
1-2.
SPEAKER REMOVAL
1-3.
CHASSIS ASSY REMOVAL
1-4.
F BOARD REMOVAL
1-5.
SERVICE POSITION
1 Two screws (+BVTP 3x12)
4 F Board
2 F Board bracket
3 Two hooks
3 DH Board
     (Not used for this model)
7 HV Cap block
2 PWB holder
5 Two screws 
     (+BVTP 3x12)
1 Two screws 
     (+BVTP 3x12)
4 One Hook
6 One screw 
     (+BVTP 4x16)
8 Bracket HVC
1-6.
HV CAP BLOCK, PWB HOLDER
REMOVAL
3 Two screws
     (+BVTP 4 
× 16)
1 Two screws
     (+BVTP 4 
× 16)
2 Two screws
     (Washer Head)
     (+P4x16)
– 8 –
KV-AR34M86
RM-993
2 V1 Board
1 Two connectors
1-9.
P5 BOARD REMOVAL
1-7.
TERMINAL BRACKET AND J BOARD
REMOVAL
1-8. D2 BOARD REMOVAL
6 Two Hooks
3 One screw
     (+BVTP 4 
× 16)
2 One screw
     (+BVTP 3 
× 12)
1 One screw
     (+BVTP 3 
× 12)
4 Two screws
     (+BVTP 3 
× 12)
5 J Board
7 Terminal bracket
2 D2 Board
1 One Hooks
1 P5 Board
2 Two screws
     (+BVTP 3x12)
Note:
• Firstly, please make sure the shield case with two screws (+BVTP 3 x 12) is remove.
1-10. V1 BOARD REMOVAL
Page of 89