Sony KV-36XBR800 (serv.man2) Service Manual ▷ View online
— 22 —
KV-36XBR800
3-3. HV SERVICE FLOWCHART
— 23 —
KV-36XBR800
4-1. SETTING SERVICE ADJUSTMENT MODE
1. Standby mode (Power off).
2. Press the following buttons on the remote commander within a
second of each other:
DISPLAY
Channel 5
Sound Volume +
Power
4-1.1. SERVICE ADJUSTMENT MODE IN
Disp.
(Item)
(Item)
Item
data
data
0
VP
HSIZ
HSIZ
7
TV
Item
order
order
SERVICE
Mode
3. The CRT displays the item being adjusted.
4. Press 1 or 2 on the Remote Commander to select the item.
5. Press 3 or 6 on the Remote Commander to change the data.
6. Press MUTING then ENTER to write into memory.
4-1.2. SERVICE ADJUSTMENT MODE
MEMORY
Disp.
(Item)
(Item)
Item
data
data
SERVICE
0
VP
HSIZ
HSIZ
7
TV
Item
order
order
7. Press 8 then ENTER on the Remote Commander to initialize.
Carry out Step 1 when adjusting
IDs 0-7 and when replacing and
adjusting IC2302
IDs 0-7 and when replacing and
adjusting IC2302
Disp.
(Item)
(Item)
Item
data
data
SERVICE
0
VP
HSIZ
HSIZ
7
TV
Item
order
order
8. Press MUTING then ENTER to write into memory.
9. DO NOT turn off set until SERVICE appears.
4-1.3. READING THE MEMORY
1. Enter into Service Mode.
2. Press 0 on the Remote Commander.
3. Press ENTER to read memory.
4-1.4. ADJUSTING THE PICTURE
1. Enter into Service Mode
2. Press 2 or 5 on the remote to select the device item.
3. Press 1 or 4 on the remote to select an item.
4. Press 3 or 6 on the remote to change the data.
5. Press MUTING then ENTER to write into memory.
4-1.5. RESETTING THE DATA
Note: Be careful when using the remote! It will clear and re-initialize
ALL NVM data including defl ection adjustment data if not reset
ALL NVM data including defl ection adjustment data if not reset
properly as follows:
4-1.6. RESETTING THE MID NVM DATA
1. Enter into Service Mode.
2. Press 7 , then JUMP , and then press ENTER on the remote.
4-1.7. RESETTING THE SYSTEM NVM DATA
1. Enter into Service Mode.
2. Press 7 , then 9 , and then press ENTER on the remote.
4-1.8. COPY FUNCTION
How to use copy function for DA4 Chassis:
• After writing your adjusted data into NVM MUTING
then ENTER , copy can be made by changing copy data from 0 to
1 then MUTING , ENTER again.
WARNING: DO NOT copy data before writing your corrected data in
NVM. If data is copied before writing corrected data, old
data will be copied.
data will be copied.
• CPY1: DF/DQP DATA
(CXA2170D-4 Item 6)
• CPY2: CONVERGENCE DATA (D-CONV Item 13)
SECTION 4: CIRCUIT ADJUSTMENTS
ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER
Use the Remote Commander (RM-Y188) to perform the circuit adjustments in this section.
Test Equipment Required:
1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
— 24 —
KV-36XBR800
4-2. MEMORY WRITE CONFIRMATION METHOD
1. After adjustment, pull out the plug from the AC outlet, then replace the plug in the AC outlet again.
2. Turn the power switch ON and set to Service Mode.
3. Call the adjusted items again to confirm they were adjusted.
2. Turn the power switch ON and set to Service Mode.
3. Call the adjusted items again to confirm they were adjusted.
4-3. REMOTE ADJUSTMENT BUTTONS AND INDICATORS
MUTING
POWER
(Enter into
memory)
(Service Mode)
DISPLAY
2
4
1
3
0
8
6
5
VOLUME (+)
ENTER
(Service Mode)
Disp. (Item up)
(Device Item Up)
Disp.
(Item Down)
(Initialize)
Item
(Data Up)
Item
(Data Down)
(Device Item
Down)
(Enter into
Memory)
(Remove from
Memory)
(Service Mode)
RM-Y188
— 25 —
KV-36XBR800
4-4. KV-36XBR800 SERVICE DATA LISTS
Category Name
No.
Item Name
Range
VERSION
0
VER
0,1
0
1
DMY1
0-255
0
Category Name
No.
Item Name
Range
3D_COMB
0
NRMD
0-3
0
1
CLKS
0-3
1
2
NSDS
0-3
0
3
MSS
0-3
0
4
KILS
0-3
1
5
FRZE
0, 1
0
6
EXCS
0-3
1
7
CDL
0-7
3
NRMD(0)
NRMD(1)
NRMD(2)
NRMD(3)
8
DYCO
0-15
2
2
2
2
9
DYGA
0-15
10
10
10
10
10
DCCO
0-15
5
5
5
5
11
DCGA
0-15
5
5
5
5
12
WSC
0-2
1
13
WSS
0, 1
0
Vivid
Standard
Movie
Pro
14
VAPG
0-7
4
2
2
0
15
VAPI
0-31
4
4
4
0
16
TEST
0, 1
0
RF
CV/YC
RF
CV/YC
RF
CV/YC
RF
CV/YC
17
YPFT
0-3
3
3
3
3
3
3
3
3
3
18
YPFG
0-15
9
6
7
5
5
6
5
5
6
19
SEDC
0, 1
0
20
SEDY
0, 1
1
21
YHCO
0-3
1
22
YHCG
0, 1
0
23
SYSP
0-3
0
24
TES2
0-7
0
Movie
Vivid
Standard
Pro
Twin