Sony KV-29FA240 (serv.man2) Service Manual ▷ View online
KV-29FA240
KV-29FA240
14
2-2. CONVERGENCE
Before starting convergence adjustments:
1 Perform FOCUS adjustments.
2. Set Picture mode to “CUSTOM”.
3. Feed in dot pattern.
1 Perform FOCUS adjustments.
2. Set Picture mode to “CUSTOM”.
3. Feed in dot pattern.
Vertical Static Convergence
1. Adjust the 4 pole magnet to converge red, green and blue dots in
the center of the screen.
4 pole magnet
RV750
H. STAT
RV1800
G2 (SCREEN)
Center dot
R G B
G
R
B
2. Tilt the 4 pole magnet and adjust static convergence to open or
close the 4 pole magnet.
3. When the 4 pole magnet is moved in the direction of arrow
A
and
B
, the red, green, and blue dots move as shown below:
Moved RV750 (H.STAT)
R
R
G
G
B
B
A
A
B
B
B
B
R
G
G
R
B
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots, use the 6
pole magnet to adjust as shown:
R G
B
R
G
B
R
G B
R
B
R
G
G
G
B
R
B
6 Pole Magnet
4 pole Magnet
DY pocket
Purity
6 Pole
Magnet
4 Pole
Magnet
Y Separation Axix Correction Magnet
Adjustment
1. Input cross hatch pattern.
2. Set Picture to “MINIMUM”, Brightness to ‘STANDARD”.
3. Adjust the Y separation axis correction magnet on the Neck
2. Set Picture to “MINIMUM”, Brightness to ‘STANDARD”.
3. Adjust the Y separation axis correction magnet on the Neck
Assembly so that the horizontal lines at the top and bottom of the
screen are straight.
Red
Blue
Red
Blue
KV-29FA240
KV-29FA240
15
Convergence Rough Adjustment
Before performing this adjustment, perform Horizontal and Vertical Static
Convergence Adjustment.
Input cross hatch pattern.
a) TLH
Adjust the horizontal convergence of red and blue dots by inserting
TLH Correction Plate to the DY pocket (left or right).
b) YCH
Adjust YCH to balance Y axis.
c) TLV
Adjust the vertical convergence of red and blue dots.
d) XCV
Adjust XCV to balance X-axis.
TLV
R B
YCH
R
B
XCV
B
R
TLH
B
R
(VR1)
TLV1 (no need to adjust)
TLV1 (no need to adjust)
DY pocket
DY pocket
TLH Plate
(VR3)
TLV2
(XCV)
(VR2)
YCH
ON DY :
Screen Corner Convergence
Affix a Piece A (110), Convergence Correct/Permaloy Assy Correction to
the misconverged areas.
b
a
c
d
a-d : screen-corner
misconvergence
a1
b1
c1
d1
a1~d1: Piece A(110), Convergence Correct
or
Permaloy Assy Correction
2-3. FOCUS ADJUSTMENT
FOCUS adjustment should be completed before White Balance
adjustment. (See 3-4. WHITE BALANCE ADJUSTMENT)
1. Receive digital monoscope pattern.
2. Set Picture Mode to “STANDARD”.
3. Adjust focus VR to obtain a just focus at the center of the screen.
4. Change the receiving signal to white pattern and blue back.
5. Confirm magenta ring is not noticeable. In case magenta ring is
2. Set Picture Mode to “STANDARD”.
3. Adjust focus VR to obtain a just focus at the center of the screen.
4. Change the receiving signal to white pattern and blue back.
5. Confirm magenta ring is not noticeable. In case magenta ring is
obvious, then adjust FOCUS VR to balance magenta ring and
FOCUS.
FLYBACK TRANSFORMER (T503)
KV-29FA240
KV-29FA240
16
2-4. SCREEN (G2)
1. Before beginning adustment procedure:
-Set Picture and Brightness to “STANDARD”.
-Set TV to Video mode.
-Set WHBL 016 “RGBB” to 01
2. Connect R, G, B of the CV board cathode to oscilloscope.
3. Adjust Brightness to obtain the cathode value to the value shown
3. Adjust Brightness to obtain the cathode value to the value shown
below:
Cathode setting voltage:
170 V
± 2 (VDC)
4. Adjust SCREEN VR on the FBT until the scanning line disappears.
5. Set WHBL 16 “RGBB” back to 00.
5. Set WHBL 16 “RGBB” back to 00.
KV-29FA240
KV-29FA240
17
3-1. REMOTE ADJUSTMENT BUTTONS AND INDICATORS
MUTING
(Enter into
memory)
memory)
8
(Initialize)
5
Display previous
Category
Category
3
Increase
Data value
Data value
0
(Remove
from memory)
from memory)
ENTER
(Enter into
memory)
memory)
6
Decrease
Data value
Data value
1
Display next
Item
Item
2
Display next
Category
Category
4
Display previous
Item
Item
DISPLAY
(Service Mode)
POWER
(Service Mode)
VOLUME (+)
(Service Mode)
RM-YA005
SECTION 3: CIRCUIT ADJUSTMENTS
Electrical Adjustments by Remote Commander
Use the Remote Commander
(RM-YA005)
to
perform the circuit adjustments in this section.
Test Equipment Required: 1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator
Click on the first or last page to see other KV-29FA240 (serv.man2) service manuals if exist.