DOWNLOAD Sony KV-29FA210 (serv.man2) Service Manual ↓ Size: 7.78 MB | Pages: 74 in PDF or view online for FREE

Model
KV-29FA210 (serv.man2)
Pages
74
Size
7.78 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kv-29fa210-sm2.pdf
Date

Sony KV-29FA210 (serv.man2) Service Manual ▷ View online

22
KV-29FA210
KV-29FA210
Hold-Down Readjustment
If the setting indicated in Step 2 of Hold-Down Operation Confi rmation 
cannot be met, readjustment should be performed by altering the 
resistance value of R530, R531 component marked with X. 
 
3mA DC range
+
-
+
-
A
+
-
FBT
TP85
T503
FBT
TP85
R531 R530
DC Power Supply
digital multimeter
ammeter
 
 
Figure 1
3-2.  B+ VOLTAGE CONFIRMATION AND 
ADJUSTMENT
Always perform the following adjustments when replacing the following 
components, which are marked with Y on the schematic diagram on the 
GW Board:
  
GW BOARD
IC600, PH602
Adjustment (Y)
1.  Using a Variac, apply AC input voltage: 130 + 2.0/-0.0 VAC
2.  Input a monoscope signal.
3.  Set the PICTURE control and the BRIGHT control to  
 
minimum.
4.  Confi rm the voltage on A Board between TP23 and ground is less than 
136.5 VDC.
5.  If step 4 is not satisfi ed, replace R530 and R531 on A Board and 
repeat the above steps.  
SECTION 3:  SAFETY RELATED ADJUSTMENTS
3-1.  R530, R531 CONFIRMATION METHOD 
(HV HOLD-DOWN CONFIRMATION) AND 
READJUSTMENTS
Always perform the following adjustments when replacing the following 
components marked with a Y  mark on the schematic diagram:
A BOARD:
HV HOLD DOWN
DY, R550, T503, T504, D519,
IC501, R533, D521, R532,
D520, C531, R529, R530,
R531, C532
R530, R531
GW BOARD:
IC600, PH602
Part Replaced (Y)
Adjustment (X)
Preparation Before Confi rmation
1.  Using a Variac, apply AC input voltage: 120 +/- 2.0 VAC.
2.  Turn the POWER switch ON.
3.  Input a white signal and set the PICTURE and BRIGHT controls to 
maximum.
4.  Confi rm that the voltage of more than 23.0 VDC appears between 
TP85 and ground on the A Board.
Hold-Down Operation Confi rmation
1.  Connect the current meter between Pin 11 of the FBT (T503) and the 
PWB land where Pin 11 would normally attach. (See Figure 1).
2.  Input a dot signal and set PICTURE and BRIGHTNESS to minimum: 
IABL = 2175 + 100/ -325 µA.
3.  Confi rm the voltage of A Board TP91 is 135 ± 1.5 VDC.
4.  Connect the digital voltmeter and the DC power supply to TP85 and 
ground. (See Figure 1).
5.  Increase the DC power voltage gradually until the picture blanks out.
6.  Turn DC power source off immediately.
7.  Read the digital voltmeter indication (standard = 27.24 + 0.0/ - 0.1 
VDC). 
8.  Input a white signal and set PICTURE and BRIGHTNESS to 
maximum: IABL = 2175 + 100/ -325 µA.
9.  Repeat steps 4 to 7.
23
KV-29FA210
KV-29FA210
4-1.  SETTING THE SERVICE ADJUSTMENT 
MODE
1.  Standby mode (Power off).
2.  Press the following buttons on the remote commander within a 
second of each other: 
 
DISPLAY  
 Channel  5  
 Sound Volume  +  
 Power
Service Adjustment Mode On
 
 
Disp.
(Item)
Item
data
0
VP
HSIZ
7
TV
Item
order
SERVICE
Mode
    
1.  The CRT displays the item being adjusted.
2. Press  1  or  2  on the Remote Commander to select the item.
3. Press 3  or   6  on the Remote Commander to change the data.
4. Press MUTING then ENTER to write into memory.
Service Adjustment Mode Memory
Disp.
(Item)
Item
data
SERVICE
0
VP
HSIZ
7
TV
Item
order
1. Press 8  then ENTER on the Remote Commander to initialize.
Disp.
(Item)
Item
data
WRITE
0
VP
HSIZ
7
TV
Item
order
Carry out Step 1 when adjusting 
ID’s 0-7 and when replacing and 
adjusting IC003.
2. Press MUTING then ENTER to write into memory.
3.   DO NOT turn off set until SERVICE appears.
4-2.  MEMORY WRITE CONFIRMATION 
METHOD
1.  After adjustment, pull out the plug from the AC outlet, then replace the 
plug in the AC outlet again.
2.  Turn the power switch ON and set to Service Mode.
3.  Call the adjusted items again to confi rm they were adjusted.
4-3.  REMOTE ADJUSTMENT BUTTONS AND 
INDICATORS
VOLUME (+)
(Service Mode)
6
Item 
(Data down)
ENTER
(Enter into 
memory)
0
(Remove from 
memory)
3
Item 
(Data up)
RM-Y180
5
(Device item 
down)
MUTING
(Enter into 
memory)
1
Disp. (Item up)
2
(Device Item Up)
4
Disp. (Item down)
8
(Initialize)
DISPLAY
(Service Mode)
POWER
(Service Mode)
SECTION 4:  CIRCUIT ADJUSTMENTS
Electrical Adjustments by Remote Commander
Use the Remote Commander (RM-Y180) to perform the circuit adjustments in this section.
Test Equipment Required:   1. Pattern generator   2. Frequency counter   3. Digital multimeter  4.  Audio oscillator
24
KV-29FA210
KV-29FA210
4-4. SERVICE DATA LISTS
Common
Init
Data
VERSION
Fix
0
VER
Microprocessor version 
information
=
Var
0
HSIZ
H SIZE (11/ 2-7)
Var
1
HPOS HPOS (12 / 2-7)
Var
2
VBOW AFC BOW (16 / 4-7)
Var
3
VANG AFC ANGLE (16 / 0-3)
Var
4
VTRP
TRAPEZIUM (20 / 3-7)
Var
5
HTRP H. TRAPEZOID (15 / 4-7)
Var
6
TROT TILT ROTATION (0-63)
Var
7
PAMP PIN AMP (13 / 2-7)
Var
8
UPIN
UP-CPIN (14 / 2-7)
Var
9
LPIN
LO-CPIN (1C / 2-7)
Var
10
VSIZ
V SIZE (0E / 2-7)
Var
11
VPOS V POSITION (0E / 2-7)
Var
12
VLIN
V LINEARITY (10 / 0-3)
Var
13
SCOR S CORRECTION (10 / 4-7)
Fix
14
VZOM 16:9 CRT Z Mode on/off
0
Var
15
EHT
Vertical High-Voltage 
Compensation
7
Fix
16
ASP
Aspect Ratio control (4:3 Mode)
47
Fix
17
ASP1
Aspect Ratio control (16:9 Mode)
47
Fix
18
SCRL
16:9 CRT Z Mode Trans. Scroll
31
Fix
19
HBLK
Horizontal Blanking on/off
1
Fix
20
LBLK
Left Blanking Adjustment
14
Fix
21
RBLK
Right Blanking Adjustment
4
Fix
22
HDW
Horizontal Drive Pulse Width
1
Fix
23
EWDC "Parabola" EW, D.C. Adjustment
0
Fix
24
LVLN
Lower Screen BTM Vertical Line 
Adj.
0
Fix
25
UVLN
Upper Screen BTM Vertical Line 
Adj.
0
Fix
26
INTL
INTERLACE
0
Fix
27
HOSC Horizontal VCO Oscillation Freq.
7
Fix
28
VSS
Vertical Sync Slice Level
0
Fix
29
HSS
Horizontal Sync Slice Level
0
Fix
30
HMSK For Macro Vision
0
Fix
31
VTMS Select Signal VTIM Pin
0
Fix
32
TCMD
Vertical Count Down Mode 
Switching (for TV)
1
Fix
33
VCMD
Vertical Count Down Mode 
Switching (for Video)
3
Fix
34
AFC
AFC Loop Gain Switching
0
Fix
35
FIFR
Field Frequency
1
Fix
36
VBLK
VBLKW
0
Fix
37
HTSW H-Trap Switch : NEW 
0
VP1
Description
Service
Group
Fix/
Var
No.
Name
25
KV-29FA210
KV-29FA210
Common
NTSC
PAL-M
PAL-N
Init
Init
Init
Init
Data
Data
Data
Data
Fix
0
REFP REFP
0
Fix
1
JPSW Jump SW
=
Var
2
SHUE Sub HUE adjustment
Var
3
SCOL Sub COLOR adjustment
Var
4
SBRT Sub BRIGHTNESS adjustment
Fix
5
SBRO Sub BRIGHTNESS adjustment for YUV
4
Fix
6
AXPL Axis PAL
0
Fix
7
AXNT Axis NTSC
1
Fix
8
CBPF Chroma BPF on/off
1
Fix
9
CTRP Y TRAP FILTER on/off
1
Fix
10
COFF Color On/off
=
Fix
11
KOFF Set Color Killer
0
Fix
12
SSHR Sub SHARPNESS for RF
5
Fix
13
SSHV Sub SHARPNESS for Video
5
Fix
14
4SPF SHARPNESS Circuit Fo (for YUV)
5
Fix
15
TSPF SHARPNESS Circuit Fo (for TV)
3
Fix
16
TSPF SHARPNESS Circuit Fo (for TV)
2
Fix
17
VSPF SHARPNESS Circuit Fo (for Video)
3
Fix
18
PREL Pre-Shoot/ Over-Shoot
1
Fix
19
ABLM ABL Mode Switch 
1
Fix
20
VTH
ABL CD VHT Switching
=
Fix
21
YDEC
Y Delay Time Control (Video4, 
SVideo1, SVideo2)
0
Fix
22
YDYS
Y Delay Time Control (RF, Video1, 
Video2, Video3)
0
Fix
23
NCOL No Color ID
1
Fix
24
FSC
FSC Out on/off
1
Fix
25
KID
Killer ID Control on/off
0
Fix
26
SHOF Offset for sharpness
0
No.
Name
Description
Fix/
Var
Service
Group
VP2
Common
NTSC
PAL-M
PAL-N
Init
Init
Init
Init
Data
Data
Data
Data
Fix
0
RDRV R DRIVE (0A / 7-2)
41
Var
1
GDRV G DRIVE (0B / 7-2)
Var
2
BDRV B DRIVE (0C / 7-2)
Fix
3
RCUT R CUT OFF ( 07 / 7-2)
31
Var
4
GCUT G CUT OFF (08 / 7-2)
Var
5
BCUT B CUT OFF (09 / 7-2)
Var
6
SCON Sub Contrast adjustment
Fix
7
CHUE Sub HUE adjustment for TV
16
Var
8
HUE4 Sub HUE adjustment for YUV
Fix
9
CCOL Sub COLOR adjustment for TV
14
18
23
Var
10
COL4 Sub COLOR adjustment for YUV
Var
11
UOFS YUV U offset
Var
12
VOFS YUV V offset
Fix
13
RON
R ON (01 / 3)
=
Fix
14
GON
G ON (01 / 2)
=
Fix
15
BON
B ON (01 / 1)
=
Var
16
HUEV Sub HUE adjustment for Video
Var
17
COLV Sub COLOR adjustment for Video
7
7
7
No.
Name
Description
Service
Group
Fix/
Var
VID_ADJUSTMENT
Page of 74
Display

Click on the first or last page to see other KV-29FA210 (serv.man2) service manuals if exist.