Sony KV-27FV300 Service Manual ▷ View online
— 10 —
KV-27FV300/29FV300/32FV300/36FV300
1-1. REAR COVER REMOVAL
1-2. CHASSIS ASSEMBLY REMOVAL
1-3. SERVICE POSITION
SECTION 1: DISASSEMBLY
Rear Cover
Claw
Chassis Assembly
A Board
GK Board
7 Screws
+BVTP 4 x 16
+BVTP 4 x 16
C Board
4 Screws
+BVTP 4 x 16
+BVTP 4 x 16
4 Screws
+BVTP 4 x 16
+BVTP 4 x 16
4 Screws
+BVTP 4 x 16
+BVTP 4 x 16
— 11 —
KV-27FV300/29FV300/32FV300/36FV300
1. Discharge the anode of the CRT and remove the anode cap.
2. Unplug all interconnecting leads from the defl ection yoke,
neck assembly, degaussing coils and CRT grounding strap.
3. Remove the Sub-Woofer Assemblies.
4. Remove the C Board from the CRT.
5. Remove the chassis assembly.
6. Loosen the neck assembly fi xing screw and remove.
7. Loosen the defl ection yoke fi xing screw and remove.
8. Place the set with the CRT face down on a cushion and
remove the degaussing coil holders.
9. Remove the degaussing coils.
10. Remove the CRT grounding strap and spring tension devices.
11. Unscrew the four CRT fi xing screws [located on each CRT
corner] and remove the CRT [Take care not to handle the
CRT by the neck].
CRT by the neck].
1-4. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock,
discharge CRT before attempting to remove the anode cap. Short between anode and CRT
coated earth ground strap.
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock,
discharge CRT before attempting to remove the anode cap. Short between anode and CRT
coated earth ground strap.
Coated
Earth
Ground
Strap
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove
the anode cap. After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT.
the anode cap. After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT.
NOTE: After removing the anode cap, short circuit the anode of the picture tube and the anode cap to either the metal chassis, CRT shield or
carbon painted on the CRT.
carbon painted on the CRT.
REMOVAL PROCEDURES
a
b
Anode Button
c
Turn up one side of the rubber cap in
the direction indicated by arrow a .
the direction indicated by arrow a .
Use your thumb to pull the rubber
cap fi rmly in the direction indicated
by arrow b .
cap fi rmly in the direction indicated
by arrow b .
When one side of the rubber cap separates from
the anode button, the anode cap can be removed
by turning the rubber cap and pulling it in the
direction of arrow c .
the anode button, the anode cap can be removed
by turning the rubber cap and pulling it in the
direction of arrow c .
HOW TO HANDLE AN ANODE CAP
1. Do not use sharp objects which may cause damage to the surface of the anode
cap.
2. To avoid damaging the anode cap, do not squeeze the rubber covering too hard.
A material fi tting called a shatter-hook terminal is built into the rubber.
3. Do not force turn the foot of the rubber cover. This may cause the shatter-hook
terminal to protrude and damage the rubber.
11
1
2
4
5
6
7
8
9
10
3
— 12 —
KV-27FV300/29FV300/32FV300/36FV300
The following adjustments should be made when a complete
realignment is required or a new picture tube is installed.
These adjustments should be performed with rated power supply
voltage unless otherwise noted.
realignment is required or a new picture tube is installed.
These adjustments should be performed with rated power supply
voltage unless otherwise noted.
The controls and switch should be set as follows unless otherwise
noted:
noted:
PICTURE CONTROL: normal
BRIGHTNESS CONTROL: normal
BRIGHTNESS CONTROL: normal
SECTION 2: SET-UP ADJUSTMENTS
Perform the adjustments in order as follows:
1. Beam
1. Beam
Landing
2. Convergence
3. Focus
3. Focus
4.
Screen (G2)/White Balance
Test Equipment Required:
1.
Color Bar Pattern Generator
2. Degausser
3.
DC Power Supply
4. Digital
Multimeter
5. Oscilloscope
6. CRT
6. CRT
Analyzer
2-1. BEAM LANDING
Preparation:
• Input a white pattern signal.
• Input a white pattern signal.
• Face the picture tube in an East or West direction to reduce the
infl uence of geomagnetism.
NOTE: Do not use the hand degausser; it magnetizes the CRT .
1. Input white pattern from pattern generator.
2. Loosen the defl ection yoke mounting screw, and set the purity control
to the center as shown below:
Purity Control
3. Input green pattern from pattern generator.
4. Move the defl ection yoke backward, and adjust with the purity control
so that green is in the center and red and blue are even on both
sides.
sides.
Blue
Red
Green
5. Move the defl ection yoke forward, and adjust so that the entire screen
becomes green.
6. Switch over the raster signal to red and blue and confi rm the
condition.
7. When the position of the defl ection yoke is determined, tighten it with
the defl ection yoke mounting screw.
8. When landing at the corner is not right, adjust by using the disk
magnets.
a
c
b
d
b
a
c
d
Purity control
corrects this area
Disk magnets
or rotatable disk
magnets correct
magnets correct
these areas (a-d)
Deflection yoke positioning
corrects these areas
— 13 —
KV-27FV300/29FV300/32FV300/36FV300
2-2. CONVERGENCE
Preparation:
• Perform FOCUS, V. LIN and V. SIZE adjustments.
• Perform FOCUS, V. LIN and V. SIZE adjustments.
• Set BRIGHTNESS control to minimum.
• Input dot pattern.
B
G
R
Center dot
V.STAT magnet
RV701 V.STAT
R G B
VERTICAL AND HORIZONTAL STATIC
CONVERGENCE
CONVERGENCE
1. Adjust V. STAT magnet to converge red, green and blue dots in the
center of the screen (Vertical movement).
Tilt the V. STAT magnet and adjust static convergence to open or
close the V. STAT magnet.
2. When the V. STAT magnet is moved in the direction of arrow a and b,
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R
G
B
G
R
B
G
B
R
B
G
R
1
2
3
a
b
a
b
b
b
a
a
b
b
a
b
a
b
OPERATION OF BMC (HEXAPOLE) MAGNET
The respective dot positions resulting from moving each magnet interact,
so perform adjustment while tracking.
so perform adjustment while tracking.
1 Use the V.STAT tabs to adjust the red, green, and blue dots so they
line up at the center of the screen (move the dots in a horizontal
direction).
direction).
R G
B
R
G
B
R
G B
R
G
B
R
G
B
R
G
B
Y SEPARATION AXIS CORRECTION MAGNET
ADJUSTMENT
ADJUSTMENT
1. Input cross-hatch pattern, adjust PICTURE to minimum and
BRIGHTNESS to normal.
2. Adjust the defl ection yoke upright so it touches the CRT.
3. Adjust so that the Y separation axis correction magnet on the neck
assembly is symmetrical from top to bottom (open state).
BMC MA
GNET
PURITY
V.STAT
4. Return the defl ection yoke to its original position.
Click on the first or last page to see other KV-27FV300 service manuals if exist.