Sony KV-24WS2B Service Manual ▷ View online
KV-24WS2
— 22 —
DISASSEMBLY
SECTION 2
2-1. REAR COVER REMOVAL
2-4-1. SERIVCE POSITION (1)
1
Five screws
(BVTP 4x16)
(BVTP 4x16)
2-2. SPEAKER REMOVAL
2-3. CHASSIS ASSY REMOVAL
Rear Cover
2
Insert into heatsink.
2
1
Snap off from main bracket.
KV-24WS2
— 23 —
2-4-2. SERVICE POSITION (2)
2-6. A EXTENSION BOARD
BE-3D EXTENSION BOARD
A board
2-5. A BOARD REMOVAL
1
Remove CN301 before removing A board.
2-7. A1 EXTENSION BOARDS
Clip bracket into Beznet.
A1 board
CN301
A board
KV-24WS2
— 24 —
2-8. PICTURE TUBE REMOVAL
•
REMOVAL OF ANODE-CAP
Note:
Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or
carbon paint on the CRT, after removing the anode.
b
b
Anode button
a
* REMOVING PROCEDURES.
c
Turn up one side of the rubber cap in
the direction indicated by the arrow a
the direction indicated by the arrow a
1
2 Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow b
arrow b
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling it up in
the direction of the arrow c
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling it up in
the direction of the arrow c
•
HOW TO HANDLE AN ANODE-CAP
Don't damage the surface of anode-cap with sharp shaped material !
Don't press the rubber hardly not to hurt inside of anode-caps !
A metal fitting called as shatter-hook terminal is built into the rubber.
Don’t turn the foot of rubber over hardly !
The shatter-hook terminal will stick out or damage the rubber
Don't press the rubber hardly not to hurt inside of anode-caps !
A metal fitting called as shatter-hook terminal is built into the rubber.
Don’t turn the foot of rubber over hardly !
The shatter-hook terminal will stick out or damage the rubber
.
1
2
3
Cushion
1
Two screws
2
Speaker
Chassis
6
9
Degaussing coil
7
DGC holders
Speaker
4
3
Two screws
Picture tube
Deflection yoke
8
DGC clips
Four tapping
screws (M)
screws (M)
Anode cap
5
11
C board
Spring tension
10
8
DGC clips
12
13
14
Click on the first or last page to see other KV-24WS2B service manuals if exist.