KLV-52X200A (CH)    2-13
Change data by service mode
Remote
1
2
Service menu
5.
5.
Write data for WEM
Write data for WEM
1.
1.
Press 
Press 
Mute
Mute
on remote. It shows green 
on remote. It shows green 
SERVICE
SERVICE
changes to  
changes to  
green 
green 
WRITE
WRITE
.
.
2.
2.
Press 
Press 
0
0
on remote. Green 
on remote. Green 
WRITE
WRITE
changes to red 
changes to red 
WRITING
WRITING
. It indicate writing is processing.
. It indicate writing is processing.
3.
3.
After about few second, red 
After about few second, red 
WRITING
WRITING
changes to green 
changes to green 
WRITE OK
WRITE OK
. Writing process is done at this point.
. Writing process is done at this point.
SERVICE
-> 
WRITE 
-> 
WRITING
-> 
WRITE OK
Set to shipping condition
Set to shipping condition
6.
6.
How to do shipping condition.
How to do shipping condition.
1.
1.
When service mode, press 
When service mode, press 
8
8
on remote .
on remote .
2.
2.
Press 
Press 
mute
mute
on remote .
on remote .
3.
3.
Press 
Press 
0
0
on remote .
on remote .
4.
4.
Display change to 
Display change to 
SERVICE
SERVICE
RST
RST
-
-
RST
RST
-
-
EXE
EXE
RST
RST
-
-
EXE
EXE
Remote
1
2
3
State of end
The error history is reset.
KLV-52X200A (CH)    2-14
2-4. UPGRADE METHOD (MS DOWNLOAD)
Upgrade All Micro by MS
Pull out the AC cable, and insert 
Pull out the AC cable, and insert 
Memory Stick.
Memory Stick.
Put AC cable in, and turn on power. 
Put AC cable in, and turn on power. 
MS download is started. See next 
MS download is started. See next 
page how to indicate progress.
page how to indicate progress.
Note that If each upgrading version 
Note that If each upgrading version 
is the same, 
is the same, 
skip
skip
upgrading.
upgrading.
Upgrade All Micro by MS
00’00” : update starts by AC ON 
EMMA update starts
(not muting)
01’00” : 
TVM update starts
(program & NVM)
07’00” : 
DEM update starts
(program & NVM)
02’30” : 
WEM update starts
(program & data)
11’10” : update end
00’50” : go to STBY mode
time
LED
OSD
Display “UPDATING”
Blinking
same as “Power ON”
same as “Standby”
DL original
No OSD
Blinking
KLV-52X200A (CH)    2-15
Upgrade All Micro by MS
After upgrading, TV
After upgrading, TV
-
-
Micro 
Micro 
REBOOT
REBOOT
and reset all micro.
and reset all micro.
AC Off.
AC Off.
Pull out Memory Stick after that.
Pull out Memory Stick after that.
When there are some troubles during upgrading, do AC 
When there are some troubles during upgrading, do AC 
cable OFF/ON with the same Memory Stick still inserted, 
cable OFF/ON with the same Memory Stick still inserted, 
and try to upgrade again. 
and try to upgrade again. 
TV set does not work correctly when Memory Stick is 
TV set does not work correctly when Memory Stick is 
pulled out while upgrading it.
pulled out while upgrading it.
2-5. ADJUSTMENTS AFTER BOARD REPLACEMENT
2-5-1. AD ADJUSTMENT
Board replacement (1)
Board replacement (1)
1.B
1.B
-
-
board (B1 or B2) replacement
board (B1 or B2) replacement
It has AD adjustment data and the replacement of this board affe
It has AD adjustment data and the replacement of this board affe
cts the signal level.
cts the signal level.
The board which we will provide has center (averaged) value for 
The board which we will provide has center (averaged) value for 
them as the 
them as the 
service parts.
service parts.
Basically you can replace the board without any operations for t
Basically you can replace the board without any operations for t
he adjusted data.
he adjusted data.
* But if the customer requested the fine level tuning for the fo
* But if the customer requested the fine level tuning for the fo
llowing input after the 
llowing input after the 
board replacement, please change the adjusted data as the follow
board replacement, please change the adjusted data as the follow
ing page.
ing page.
<Target input and data for the fine tuning>
<Target input and data for the fine tuning>
-
-
Main picture / CVBS input (NTSC, PAL, SECAM)/ Y
Main picture / CVBS input (NTSC, PAL, SECAM)/ Y
-
-
level
level
-
-
Main picture / Analog RF input (NTSC, PAL, SECAM)/ Y
Main picture / Analog RF input (NTSC, PAL, SECAM)/ Y
-
-
level
level
(Regarding the C
(Regarding the C
-
-
Level, it doesn't have large dispersion. You don't have to chang
Level, it doesn't have large dispersion. You don't have to chang
it.)
it.)
KLV-52X200A (CH)    2-16
Board replacement (2)
Board replacement (2)
2.A
2.A
G
G
-
-
board replacement
board replacement
It has AD adjustment data and the replacement of this board affe
It has AD adjustment data and the replacement of this board affe
cts the signal level.
cts the signal level.
The board which we will provide has center (averaged) value for 
The board which we will provide has center (averaged) value for 
them as the 
them as the 
service parts. 
service parts. 
Basically you can replace the board without any operations for t
Basically you can replace the board without any operations for t
he adjusted data.
he adjusted data.
* But if the customer requested the fine level tuning for the fo
* But if the customer requested the fine level tuning for the fo
llowing input after the 
llowing input after the 
board replacement, please change the adjusted data as the follow
board replacement, please change the adjusted data as the follow
ing page.
ing page.
<Target input and data for the fine tuning>
<Target input and data for the fine tuning>
-
-
Main picture / CVBS input (NTSC, PAL, SECAM)/ Y
Main picture / CVBS input (NTSC, PAL, SECAM)/ Y
-
-
level
level
-
-
Main picture / Analog RF input (NTSC, PAL, SECAM)/ Y
Main picture / Analog RF input (NTSC, PAL, SECAM)/ Y
-
-
level
level
(Regarding the C
(Regarding the C
-
-
Level, it doesn't have large dispersion. You don't have to chang
Level, it doesn't have large dispersion. You don't have to chang
it.)
it.)
Board replacement (3)
Board replacement (3)
3.
3.
TUG
TUG
-
-
board replacement
board replacement
It doesn't have AD adjustment data but the replacement of this b
It doesn't have AD adjustment data but the replacement of this b
oard affects the 
oard affects the 
signal level.
signal level.
Basically you can replace the board without any operations for t
Basically you can replace the board without any operations for t
he adjusted data.
he adjusted data.
* But if the customer requested the fine level tuning for the fo
* But if the customer requested the fine level tuning for the fo
llowing input after the 
llowing input after the 
board replacement, please change the adjusted data as the follow
board replacement, please change the adjusted data as the follow
ing page.
ing page.
<Target input and data for the fine tuning>
<Target input and data for the fine tuning>
-
-
Main picture / Analog RF input (NTSC, PAL, SECAM)/ Y
Main picture / Analog RF input (NTSC, PAL, SECAM)/ Y
-
-
level
level
(Regarding the C
(Regarding the C
-
-
Level, it doesn't have large dispersion. You don't have to chang
Level, it doesn't have large dispersion. You don't have to chang
it.)
it.)
Page of 127
Display

Click on the first or last page to see other KLV-52X200A service manuals if exist.