– 16 –
KLV-26T400A, T400G, 32T400A
RM-GA013
4-2-5. AC Power Cord Wire Dressing (Before 
 
installing G1 Bracket with GPT PWB) for CISPR Models. 
4-2-6. Dressing of Connector Assy 10P and 14P
1) Install Ferrite core to AC power cord at specified position as shown. 
2) Attach Tape, Shield (X2) on to specified position. 
3) Next, wrap Sheet Core, E around area of Tape, Shield on AC power cord, to cover it.
4) Finally, install AC cord holder to AC power cord at specified position.
5) Attach Tape, Shield to AC power cord (X2) at specified position.
6) Attach Sheet Core, C to overlap the two Tape, Shields.
    
This is to prevent the Tape, Shields from peeling off.
Attach Tape, LCD to Connector Assy 10P and Connector Assy 14P as shown.
 
Use datum lines as an 
indication for attaching 
Tape, LCD to 
Connector Assy 14P 
 
 
Use datum lines as an indication for attaching
Tape, LCD to Connector Assy 10P 
Ferrite Core
Tape, Shield (X2)
Wrap Sheet Core, E around area of Tape, 
 Shield on AC Power Cord, to Cover it  
CISPR models only
Attach Sheet Core, C to Tape, Shields. 
Make sure it overlaps the Tape, Shields. 
CISPR models only
Attach Tape, Shield to AC Power Cord (X2)
Use edge of Inverter board's cover and AC power cord 
connector as a guideline for placement of power cord 
Portion of AC Power Cord with Sheet Core, E
When installing AC cord holder, make sure 
the Sheet Core, E area is clamped as well 
Attach Tape, LCD
(2X)
Dress Conn Assy 10P
below Frame, Spine 
Attach Tape, LCD (1X)
360 ± 5mm 
Ferrite Core
Tape, Shield (X2)
AC Cord Holder
Sheet Core, E
140± 5mm
285± 5mm
2
1
3
6
5
4
– 17 –
KLV-26T400A, T400G, 32T400A
RM-GA013
 4-2-7. LVDS Harness Dressing
4-2-8.  Dressing of Connector Assy 10P and Connector Assy 14P on G1 Bracket
See steps below for LVDS harness and SP Connector Assy 4P wire dressing.
Note: When inserting LVDS harness to panel, make sure it is
          fully inserted and in the correct direction as shown.
1) Dress Connector Assy 10P into G1 bracket's hook (1X) as shown.
2) Next, dress Connector Assy 14P into G1 bracket's hook (4X).
 
CN3000
CN3000
CISPR model
Non-CISPR model
OK
NG
Conn Assy 10P is below G1 bracket
Keep distance between Conn 
Assy 10P and SP Conn Assy 4P
Dress Conn Assy 
10P into G1 bracket's 
hook (1X)
Attach Sheet Core, C
to LVDS harness.
LVDS harness
SP Conn Assy 4P below 
LVDS harness
SP Conn Assy 4P below 
LVDS harness
Screw earth clamps 
(2X)
LVDS harness
Dress Conn Assy 14P into G1 bracket's hook (4X)
2
1
– 18 –
KLV-26T400A, T400G, 32T400A
RM-GA013
 4-2-9. Dressing of Connector Assy 14P, 
 
Connector Assy 13P and Connector 
 
Assy 10P
4-2-10.  AC Power Cord Wire Dressing
4-2-11.  AC Power Cord Wire Dressing
1) Dress Connector Assy 13P into G1 bracket's hook as shown.
2) Align Connector Assy 14P, Connector Assy 10P and Connector
  Assy 13P together and dress them using Sheet Core, C.
1) Install AC cord holder to AC power cord at specified position as 
  shown.
2) Then install the AC power cord with holder into AC cord bracket.
1) Attach Sheet Core, C to Vesa Frame Bottom (32).
2) Insert AC power cord into CN6102.
3) Install the AC power cord with holder into Bracket, AC.
4) Then, install Bracket, AC into Bracket, Bottom.
5) Attach Sheet Core, C to Ferrite Core.
6) Lastly, dress AC power cord using pin, wire A6101 as shown.
80 ± 5mm 
Non-CISPR model
1
CAUTION:
1. Ensure that AC power cord is not stressed 
  whilst inserting it into AC cord bracket.
CISPR model
Connecto
Assy 10P
Ferrite, Core
Bracket, AC
CAUTION:
1. Ensure that AC power cord is not stressed whilst
  inserting it into AC Cord bracket. 
Connector Assy 14P
Dress Conn Assy 13P into
G1 bracket's hook (1X)
Connector Assy 13P
AC cord bracket
Install AC power cord with
holder into AC cord bracket
Attach Sheet Core, C
to Vesa Frame Bottom (32)
Insert AC power
cord to CN6102.
Install AC power cord
with holder into 
Bracket, AC
Bracket, AC
Bracket, 
Bottom
Install Bracket, AC into Bracket, Bottom
AC Cord that is looped around
Ferrite Core is inserted under
Frame, Spine
Attach Sheet Core, C
to Ferrite Core
Dress AC power 
cord using pin, wire
A6101
Dress Conn Assy 14P, Conn 
Assy, 10P and Conn Assy 13P
using Sheet, Core, C
2
2
1
5
6
4
1
3
2
– 19 –
KLV-26T400A, T400G, 32T400A
RM-GA013
 4-2-12. AC Power Cord Wire Dressing at Rear Cover
Hook the AC-band to the
rear cover.
Tie the root of the AC plug.