– 12 –
KLV-26T400A, T400G, 32T400A
RM-GA013
4-1-7. SP Connector Assy 4P Dressing for 26T400A
4-1-8. LVDS Harness and SP Connector Assy 4P Dressing
1
SP Connector Assy 4P wire dressing for 26T400A model as below.
See steps below for LVDS harness and SP Connector Assy 4P wire dressing.
Note: When inserting LVDS harness to panel, 
          make sure it is fully inserted and in the correct
          direction as shown.
  See steps below for LVDS harness and SP Connector Assy 4P wire dressing.
Note: When inserting LVDS harness to panel, make sure it is fully
          inserted and in the correct direction as shown.
SP Conn 
Assy 4P
Conn Assy 14P
Attach Tape, 
LCD (3X)
KLV-26T400A Non-CISPR model
Make sure LVDS harness is fully 
inserted in direction as shown
When attaching Tape, LCD, ensure that it 
covers and hides the SAMSUNG logo
26T400A CISPR model
Make sure LVDS harness is fully 
inserted with direction as shown
Screw earth clamps (X2)
Attach Tape LCD (X3)
Be careful not to 
cover the bar code
SP Conn 
Assy 4P
Keep distance between SP Conn 
Assy 4P and:
T-CON, Conn Assy 14P
T-CON
1
2
3
Connect LVDS 
harness
Attach Tape, LCD 
(X3)
Attach Sheet Core, C
to LVDS harness
Make sure SP Conn Assy 4P is above this 
area as Vesa Frame will be assembled later
Be careful not to cover the 
bar code
Make sure SP Conn Assy 4P is above 
this area as Vesa Frame will be 
assembled later
2
3
Connect LVDS harness
When attaching Tape, LCD, ensure that it 
covers and hides the SAMSUNG logo
– 13 –
KLV-26T400A, T400G, 32T400A
RM-GA013
4-1-9. SP Connector Assy 4P Dressing for KLV-26T400G
4-1-10 LVDS Harness and SP Connector Assy 4P Dressing for KLV-26T400G
4-1-11. Dressing of Connector Assy 14P
4-1-12. Dressing of Connector Assy 14P,
 
Connector 
Assy 13P and Connector
 
Assy 10P
SP Connector Assy 4P wire dressing for 26T400G model as below.
See steps below for LVDS harness and SP Connector Assy 4P wire dressing.
Note: When inserting LVDS harness to panel,
 
make sure it is fully inserted and in the
 
correct direction as shown.
Dress Connector Assy 14P into G1 bracket's hook (4X) as shown.
1) Dress Connector Assy 13P into G1 bracket's hook as shown.
2) Align Connector Assy 14P and Connector Assy 13P together
  and dress them using Sheet Core, C.
Keep distance between SP 
Conn Assy 4P and:
T-CON, Conn Assy 14P
SP Conn Assy 
4P
Conn Assy 14P
Attach Tape, LCD (3X)
Make sure LVDS harness is fully 
inserted with direction as shown
Attach Sheet Core, C
to LVDS harness
Make sure SP Conn Assy 4P is above 
this area as Vesa Frame will be 
assembled later
Attach Tape LCD (X3)
Be careful not to cover 
the bar code
When attaching Tape, LCD, ensure that it covers 
and hides the SAMSUNG logo
Dress Conn Assy 14P into
G1 bracket's hook (4X)
Dress Conn Assy 13P into G1 bracket's hook (1X)
Connector Assy 10P
Connector Assy 14P
Common for all 26T400 models
SP Conn Assy 
4P
T-CON
Connect LVDS harness 
1
2
3
4
5
Caution: Dress wires downward towards the panel and bezel.
Ensure capacitor does not touch tweeter or any conductive parts.
Attach Tape LCD (X1)
 to wire and panel
Attach Tape LCD (X1)
 to wire and panel
Dress Conn Assy 14P and 
Conn Assy 13P using Sheet, 
Connector Assy 13P
1
2
– 14 –
KLV-26T400A, T400G, 32T400A
RM-GA013
 4-1-13.  AC Power Cord Wire Dressing
4-1-14.  AC Power Cord Wire Dressing at Rear Cover
1) Install the AC power cord with holder into AC cord bracket.
2) Dress the AC power cord wire pin, wire A6101.
1) Install the AC power cord with holder into AC cord bracket.
2) Dress the AC power cord using Sheet Core, C on to main bracket.
3) Dress the AC power cord wire pin, wire A6101.
CAUTION:
1. Ensure that AC power cord is not stressed
  whilst inserting it into AC cord bracket.
Dress AC Power Cord using Sheet 
Core, C on to Main Bracket
Non-CISPR model
CISPR model
No need to attach Sheet 
Core, C here
Tie the root of the AC 
plug.
Hook the AC-band to
the rear cover.
2
3
1
2
1
Dress AC power cord 
with pin, wire A6101
Install AC power cord with 
holder into AC cord bracket
AC cord bracket
AC cord bracket
Install AC power 
cord with holder 
into AC cord 
bracket
Dress AC power cord 
with pin, wire A6101
– 15 –
KLV-26T400A, T400G, 32T400A
RM-GA013
4-2-1. Wire Dressing overview for  
 
Non-CISPR model.
4-2-2. Wire Dressing overview for CISPR model.
1) Insert Connector Assy 1P to HT PWB's screw hole and bracket  
  bottom's screw hole as shown.
2) Attach Sheet Core, C (X1) to panel at location of Connector  
  Assy 10P. 
1) See steps 1 ~ 3 below for SP Connector Assy 4P wire dressing. 
4-2-3.  Dressing of Connector Assy 1P
HT PWB
45º
Conn Assy 1P
Attach  
Sheet  
Core, C to 
pane
 
 
Use datum lines as reference
Use datum lines
as reference
Use datum lines as reference
SP Conn Assy 4P
Use datum line as reference
 
SP Conn Assy 4P 
is below Frame,  
Spine 
 
Use datum lines as reference
Use dowel 
as guide to 
attach Conn 
Assy 1P
Bracket, 
Bottom
 
Conn Assy 10P 
is above Conn  
Assy 1P 
4-2-4. SP Connector Assy 4P Dressing     
Attach Tape, LCD (3X). 
Ensure wires go around  
inverter board. 
 
SP Conn Assy 4P is below Frame, Spine
1
1
3
2
2
Attach Tape, LCD (2X)
4.2 (KLV-32T400)