Sony KF-E42A10 / KF-E50A10 (serv.man7) Service Manual ▷ View online
46
KF-E42A10/E50A10
KF-E42A10/E50A10
CHASSIS ASSEMBLY (2 OF 3)
Caution Points
Tool / Torque
5
6
Install Connector Assy 1-910-015-20 between CN8402
and CN9504. Dress cables in two coated pins
mounted on AGA-Bd.
CAUTION
: Dress wires above P-Bd shield PARALLEL to
PWB. Coated pin and wires must touch P-Bd shield.
Install Shield covers (p/n:2-596-915-01; 2-596-915-11) on AGA-Bd.
7
8
Install Conn. Assy. 1-910-015-23 on CN8815 and dress in coated
lead pin.
lead pin.
Install Conn. Assy. 1-910-015-28 to CN8404 and dress in coated
lead pin CL8003.
CAUTION
: Make sure clamp and cables are touching side of
shield cases.
-Phillips Screw Driver
-[3x12mm]
-7kg-cm +-0.5kg-cm
-[3x8mm]
- 5kg-cm +-0.5kg-cm
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
47
KF-E42A10/E50A10
KF-E42A10/E50A10
CHASSIS ASSEMBLY (3 OF 3)
Caution Points
Tool / Torque
9
Install AGA-Bd on GTA-Bd.
CAUTION
: Make sure connector is completely
connected/locked. Make sure there is no gap
between mating parts.
10
Install Conn. Assy. 1-910-015-17 Lighning ground to GTA-Bd
CN6011 CN6012.
CN6011 CN6012.
Use 20x50mm himelon tape to hold insulation tube against AGU
shield (4-079-129-21).
shield (4-079-129-21).
CAUTION
: Make sure wires are slightly higher than the top of
heat sinks adjacent to AGU shield. This is LOWER than on
TROY DIGITAL models.
TROY DIGITAL models.
-Phillips Screw Driver
-[3x12mm]
-7kg-cm +-0.5kg-cm
-[3x8mm]
- 5kg-cm +-0.5kg-cm
10a
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
48
KF-E42A10/E50A10
KF-E42A10/E50A10
K BOARD ASSEMBLY
Caution Points
Tool / Torque
1
Install K-Bd into K-Bracket (p/n:2-593-079-11). Fix K-Bd with 3x12mm
screw
(p/n:7-685-648-79)
[2 places].
Install Conn. Assy. 1-910-015-19 in CN3002. Apply 11mm
purselock
(p/n:4-049-281-01) and
one loop to cable (as shown).
Install Wire harness saddle (p/n:4-071-125-11) to K-Bracket.
Install Conn. Assy. 1-910-015-30 to CN3001
-Phillips Screw Driver
-[3x12mm]
- 7kg-cm +-1.0kg-cm
49
KF-E42A10/E50A10
KF-E42A10/E50A10
LIGHTNING GROUND INSTALLATION (1 OF 4)
Caution Points
Tool / Torque
1
2
Position Lightning ground wire (p/n:1-910-015-17).
Use Cable tie on cables to position cable just right of
purselock on C-Shield case.
Apply 20x50mm himelon tape to secure wires on Optical Block.
P/n: 4-079-129-21.
CAUTION
: Make sure to confirm position of wire before applying himelon.
In addition make sure no bubbles or gaps are under the tape after
applying.
3
4
Route all lightning ground wires UNDER Fan on Duct Block.
Dress Lightning Ground wires inside long purselock on C-Shield
p/n:4-077-726-10
Please Follow All
CAUTION
points listed. It
is important to control
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
VARIATION of wire
routing for minimizing
Electro Maagnetic
Interference (EMI)
Click on the first or last page to see other KF-E42A10 / KF-E50A10 (serv.man7) service manuals if exist.