DOWNLOAD Sony KF-E42A10 / KF-E50A10 (serv.man7) Service Manual ↓ Size: 13.15 MB | Pages: 127 in PDF or view online for FREE

Model
KF-E42A10 KF-E50A10 (serv.man7)
Pages
127
Size
13.15 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kf-e42a10-kf-e50a10-sm7.pdf
Date

Sony KF-E42A10 / KF-E50A10 (serv.man7) Service Manual ▷ View online

 46 
KF-E42A10/E50A10
KF-E42A10/E50A10
CHASSIS ASSEMBLY (2 OF 3)
Caution Points
Tool / Torque
5
6
Install Connector Assy 1-910-015-20 between CN8402 
and CN9504. Dress cables in two coated pins
mounted on AGA-Bd.
CAUTION
: Dress wires above P-Bd shield PARALLEL to
PWB. Coated pin and wires must touch P-Bd shield.
Install Shield covers (p/n:2-596-915-01; 2-596-915-11) on AGA-Bd.
7
8
Install Conn. Assy. 1-910-015-23 on CN8815 and dress in coated 
lead pin.
Install Conn. Assy. 1-910-015-28 to CN8404 and dress in coated 
lead pin CL8003.
CAUTION
: Make sure clamp and cables are touching side of 
shield cases.
-Phillips Screw Driver
-[3x12mm]
-7kg-cm +-0.5kg-cm
-[3x8mm]
- 5kg-cm  +-0.5kg-cm
Please Follow All 
CAUTION
points listed. It 
is important to control 
VARIATION of wire 
routing for minimizing 
Electro Maagnetic
Interference (EMI)
 47 
KF-E42A10/E50A10
KF-E42A10/E50A10
CHASSIS ASSEMBLY (3 OF 3)
Caution Points
Tool / Torque
9
Install AGA-Bd on GTA-Bd.
CAUTION
: Make sure connector is completely
connected/locked. Make sure there is no gap
between mating parts.
10
Install Conn. Assy. 1-910-015-17 Lighning ground to GTA-Bd
CN6011 CN6012. 
Use 20x50mm himelon tape to hold insulation tube against AGU 
shield (4-079-129-21).
CAUTION
: Make sure wires are slightly higher than the top of 
heat sinks adjacent to AGU shield.  This is LOWER than on 
TROY DIGITAL models.
-Phillips Screw Driver
-[3x12mm]
-7kg-cm +-0.5kg-cm
-[3x8mm]
- 5kg-cm  +-0.5kg-cm
10a
Please Follow All 
CAUTION
points listed. It 
is important to control 
VARIATION of wire 
routing for minimizing 
Electro Maagnetic
Interference (EMI)
 48 
KF-E42A10/E50A10
KF-E42A10/E50A10
K BOARD ASSEMBLY
Caution Points
Tool / Torque
1
Install K-Bd into K-Bracket (p/n:2-593-079-11). Fix K-Bd with 3x12mm 
screw
(p/n:7-685-648-79) 
[2 places].
Install Conn. Assy. 1-910-015-19 in CN3002. Apply 11mm 
purselock
(p/n:4-049-281-01) and
one loop to cable (as shown).
Install Wire harness saddle (p/n:4-071-125-11) to K-Bracket.
Install Conn. Assy. 1-910-015-30 to CN3001
-Phillips Screw Driver
-[3x12mm]
- 7kg-cm  +-1.0kg-cm
 49 
KF-E42A10/E50A10
KF-E42A10/E50A10
LIGHTNING GROUND INSTALLATION (1 OF 4)
Caution Points
Tool / Torque
1
2
Position Lightning ground wire (p/n:1-910-015-17).
Use Cable tie on cables to position cable just right of
purselock on C-Shield case.
Apply 20x50mm himelon tape to secure wires on Optical Block.
P/n: 4-079-129-21.
CAUTION
: Make sure to confirm position of wire before applying himelon.
In addition make sure no bubbles or gaps are under the tape after
applying.
3
4
Route all lightning ground wires UNDER Fan on Duct Block.
Dress Lightning Ground wires inside long purselock on C-Shield
p/n:4-077-726-10
Please Follow All 
CAUTION
points listed. It 
is important to control 
VARIATION of wire 
routing for minimizing 
Electro Maagnetic
Interference (EMI)
Page of 127
Display

Click on the first or last page to see other KF-E42A10 / KF-E50A10 (serv.man7) service manuals if exist.