DOWNLOAD Sony KE-32TS2E / KE-32TS2U Service Manual ↓ Size: 5.4 MB | Pages: 79 in PDF or view online for FREE

Model
KE-32TS2E KE-32TS2U
Pages
79
Size
5.4 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / PANEL MODULE
File
ke-32ts2e-ke-32ts2u.pdf
Date

Sony KE-32TS2E / KE-32TS2U Service Manual ▷ View online

 
 
 
    
 
-70-
(3) Judgment 
 
Item 
Test items 
Test signal 
Judgment criterion 
1 Brightness 
non-uniform
ity 
White screen (W) 
Brightness non-uniformity in the form of stripes 
must not be visible in vertical and horizontal 
directions.  
Black noise 
Horizontal gray scale 
 (Each color of R/G/B) 
Rank 3 or higher in the 5-step evaluation.  
<Rank> 
5:  No noise 
4:  Small noise is intermittently visible 
3:  Noise of 1 line is not visible continuously 
2:  Noise occurs continuously 
1:  Much noise occurs continuously 
3 Number 
of 
defects 
4 Number 
of 
extra dots 
5 Number 
of 
flickering 
dots 
The entire screen lights 
 (Each color of 
W/R/G/B) 
Conforms to Section 1.3.2 Display quality 
specifications. 
However, when Delivery Specifications Sheets are 
prepared for each client, the specifications shown in 
the Delivery Specifications Sheet must be met. 
         
(4)  Power ON/OFF 
・ 
Power  ON 
                        Both PDPGO-SW and CPUGO-SW are made set of turning on.  
・ 
Power OFF 
       Only PDPGO-SW is made set of turning off.   
       (CPUGO-SW is in the state of turning on.) 
        
 
 
 
 
    
 
-71-
6.2.4 Heat 
Run 
Test 
(1)   Set the module by following the same procedure as that for Problem Analysis in Section 4.7.  
(2)   From the main menu, select the POWER ON menu with the ↑key or ↓key and press the <ENTER> 
key.  
 
 
 
 
 
 
 
 
(3)   From the POWER ON menu, select the Module power with the ↑key or ↓key and press the <ENTER> 
key. When you press the →key, the main power of the module is turned on.  (When you press the ←key, 
the main power is turned off.) 
 
 
 
 
 
 
 
 
 
 
 
 (4)  To change the internal pattern, select the internal pattern selection from the POWER ON menu using the ↑
(up) or ↓(down) key, and press the <ENTER> key. 
Setup 
value 
Display pattern 
Setup 
value 
Display pattern 
00 
01 to 08 patterns are displayed 
every 2 seconds.  
05 
Entire screen is cyan 
01 
Entire screen is blue 
06 
Entire screen is yellow 
02 
Entire screen is red 
07 
Entire screen is white 
03 
Entire screen is magenta 
08 
Entire screen is black 
04 
Entire screen is green 
09 
Plant burn-in pattern 
(5) 
From the POWER ON menu, select Burn-in start with the ↑key or↓key and press the <ENTER> key. 
The display pattern is automatically generated in PDP. 
(6) 
Select RETURN with ↑key or↓key and press <ENTER> key to return to the menu screen  
32H2   Main menu 
   Module information menu 
** Power ON menu 
   Problem analysis menu 
   Voltage adjustment menu 
   Accumulated power-on time menu 
   Logic board change menu 
 
  EXIT 
32H2   Power ON menu 
** Internal pattern selection :** 
   00 - changing colors (full picture) 
   01 - blue                           
   02 - green   or red                 
   03 - syan    or magenta             
   04 - red     or green               
   05 - magenta or syan                
   06 - yellow                         
   07 - white                          
   08 - black                          
   10 - factory pattern (OLD)          
   77 - factory pattern 
   Burn–in start / execute  
   RETURN 
   EXIT 
 
 
 
    
 
-72-
6.2.5  Logic board parameter forwarding 
(1) The module is set according to the same to failure analysis procedure in clause 4.7. 
The logic board before being exchanged is installed in the module. 
 
    
(2) From the main menu, select change Logic board menu with the ↑key or ↓key and press the <ENTER> key. 
 
 
 
 
 
 
 
 
 
    
(3) From the logic board change menu, select data copy with the ↑key or ↓key  and press the <ENTER> key. 
 Data is read before the Logic board is exchanged. 
 
 
 
 
 
(4) The Logic board is exchanged. 
 
(6) From the logic board change menu, select data paste with the↑key or ↓key and press the<ENTER> key. Data  
is written in the exchanged Logic board. 
 
 
 
 
 
 
(6) Select RETURN with ↑key or ↓key  and press <ENTER> key to return to the menu screen. 
 
 
 
 
 
32H2   Main menu 
   Module information menu 
** Power ON menu 
   Problem analysis menu 
   Voltage adjustment menu 
   Accumulated power-on time menu 
   Logic board change menu 
 
   EXIT 
32H2   Logic board change menu 
** Data copy (PDP -> Temp.FILE)/execute 
   Data Paste (PDP -> Temp.FILE)/execute 
   RETURN 
   EXIT 
32H2   Logic board change menu 
   Data copy (PDP -> Temp.FILE)/execute 
** Data Paste (PDP -> Temp.FILE)/execute 
   RETURN 
   EXIT 
 
 
 
    
 
-73-
   
6.2.6 Accumulation time reset 
(1) The module is set according to the same to failure analysis procedure in clause 4.7. 
 
     
 (2) From the main menu, select Power-on time menu with the ↑key or ↓key and press the <ENTER> key. 
 
 
 
 
 
 
 
 
 
   
(3) From the Power-on time menu, select Operation hours with the ↑key or ↓key and press the <ENTER> key.    
The Operation hour is input.   *It is not possible to change in the energizing time according to the version of the 
service software. 
 
 
 
 
 
     
(4) "minute" is continuously input and < ENTER > key is pushed. 
            (5) "Second" is continuously input and < ENTER > key is pushed. 
 
    (6) Select RETURN with ↑key or ↓key and press <ENTER> key to return to the  menu screen. 
 
 
 
 
 
 
 
 
 
 
 
 
32H2   Main menu 
   Module information menu 
   Power ON menu 
   Problem analysis menu 
   Voltage adjustment menu 
** Accumulated power-on time menu 
   Logic board change menu 
 
   EXIT 
32H2  Accumulated power-on time menu 
** Running time indication:[hh:mm:ss]= 
 
   RETURN 
   EXIT 
Page of 79
Display

Click on the first or last page to see other KE-32TS2E / KE-32TS2U service manuals if exist.