4.7.3  Problem Analysis Procedure 
(1) 
Select the problem analysis menu from the main menu using the 
↑ key or ↓ key and press 
<ENTER> key to start the program.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   Module information menu 
   POWER ON menu 
** Problem analysis menu 
   Voltage adjustment menu 
   Accumulated power-on time menu 
   Logic board change menu 
 
   EXIT 
 32H2    Main menu          <Rev. SVH2E 1.0>
  
 
 
 
 
-47-
 
(2) Check the error code (hexadecimal number) from the Latest error code read-out menu and locate the 
faulty position from the following table. 
32H2    Problem analysis menu
**_Condition code
:** (Hex)
   Latest error code
:** (Hex)
   Previous error Code
:** (Hex)
    2nd previous error code
:** (Hex)
    3rd previous error code
:** (Hex)
    4th previous error code
:** (Hex)
    5th previous error code
:** (Hex)
    6th previous error code
:** (Hex)
    7th previous error code
:** (Hex)
    8th previous error code
:** (Hex)
    9th previous error code
:** (Hex)
   10th previous error code
:** (Hex)
   11th previous error code
:** (Hex)
   12th previous error code
:** (Hex)
   13th previous error code
:** (Hex)
   14th previous error code
:** (Hex)
   15th previous error code
:** (Hex)
   Error code clear / execute
   RETURN
   EXIT
モジュールの状態
を示します。
最新のエラーコー
ドを示します。
過去のエラーコー
ドを新しい順に示
します。
全エラーコードを
0クリアします。
故障解析メニューの表示例
 
 
 
(3) 
Select RETURN using the 
↑ key or ↓ key and press <ENTER> key to start the program, then the 
screen returns to the menu screen.  
*  When EXIT is selected, the screen returns to the WINDOWS or DOS screen.  
 
The state of the module is shown.
The latest error code is shown. 
A past error code is shown in new 
the order. 
All error code is cleared to 0. 
Example of displaying breakdown analysis menu 
  
 
 
 
 
-48-
Error code table
 
Suspected faulty board  
(In the order of higher probability of defect)  
ERR 
code 
Detect 
position 
(board) 
Contents 
(1) (2) (3) (4) (5) (6) (7) 
Remarks 
00 
LOGIC  STANDBY power is stopped 
PSU 
 
 
 
 
 
 
PSU temperature has 
probably  increased 
02 
Waveform ROM data error 
LOGIC 
 
 
 
  【UA-7x】 
04 
LOGIC 
3.3V power voltage has dropped 
LOGIC 
PSU 
 
 
 
06 
 
3.3V power startup is faulty 
X-SUS 
Y-SUS 
ADM1 - 8 PSU 
ABUS-L ABUS-R  LOGIC 
18 
 
Internal I2C_SCL1_LOW level 
LOGIC 
 
 
 
19 
 
Internal I2C_ACK does not respond 
LOGIC 
 
 
 
1C 
 
EEPROM initial setting is defective 
LOGIC 
 
 
 
1D 
 
EEPROM write-down is defective 
LOGIC 
 
 
 
1E 
 
EEPROM user initial setting is defective 
LOGIC 
 
 
 
1F 
 
EEPROM factory setting reading is defective 
LOGIC 
 
 
 
24 
X-SUS  Vex power voltage has decreased 
X-SUS 
LOGIC
 
 
 
25 
 
Vex power voltage is excessive 
X-SUS 
 
 
 
26 
 
Vex power startup is faulty. 
X-SUS 
LOGIC
 
 
 
28 
 
Vx power voltage has dropped 
X-SUS 
LOGIC
 
 
 
29 
 
Vx power voltage is excessive 
X-SUS 
 
 
 
2A 
 
Vx power startup is faulty. 
X-SUS 
LOGIC
 
 
 
2C 
 
Vpx voltage has dropped 
X-SUS 
LOGIC
 
 
 
2D 
 
Vpx voltage is excessive 
X-SUS 
LOGIC
 
 
 
30 
 
Vpx1 voltage has dropped 
X-SUS 
LOGIC
 
 
 
 
31 
 
Vpx1 voltage is excessive 
X-SUS 
LOGIC
 
 
 
 
34 
 
Vpx2 voltage has dropped 
X-SUS 
LOGIC
 
 
 
 
35 
 
Vpx2 voltage is excessive 
X-SUS 
LOGIC
 
 
 
 
39 
 
Vs power current is excessive (during operation) X-SUS 
Panel 
LOGIC 
 
 
 
3B 
 
Vs power current is excessive (during startup) 
X-SUS 
Panel 
LOGIC 
 
 
 
44 
Y-SUS  Vey power voltage has dropped 
Y-SUS 
LOGIC
 
 
 
45 
 
Vey power voltage is excessive 
Y-SUS 
 
 
 
46 
 
Vey power startup is faulty. 
Y-SUS 
LOGIC
 
 
 
4C 
 
Vpy voltage has dropped 
Y-SUS 
LOGIC
 
 
 
4D 
 
Vpy voltage is excessive 
Y-SUS 
LOGIC
 
 
 
50 
 
Vpy1 voltage has dropped 
Y-SUS 
LOGIC
 
 
 
 
51 
 
Vpy1 voltage is excessive 
Y-SUS 
LOGIC
 
 
 
 
54 
 
Vpy2 voltage has dropped 
Y-SUS 
LOGIC
 
 
 
 
55 
 
Vpy2 voltage is excessive 
Y-SUS 
LOGIC
 
 
 
 
59 
 
Vs power current is excessive (during operation) Y-SUS 
Panel 
LOGIC 
 
 
 
5B 
 
Vs power current is excessive (during startup) 
Y-SUS 
Panel 
LOGIC 
 
 
 
5D 
 
Vs power current is excessive (during operation) Y-SUS 
SDM 
Panel 
LOGIC
 
 
 
61 
PSU 
Vs power voltage is excessive 
PSU 
LOGIC
 
 
 
62 
 
Vs power startup is faulty. 
X-SUS 
Y-SUS 
PSU 
LOGIC
 
 
 
64 
Vex and Vpy power voltage has dropped 
LOGIC 
X-SUS 
Y-SUS 
 
 
 
65 
Vex and Vey power voltage is excessive 
X-SUS 
Y-SUS 
 
 
 
66 
X-SUS 
Y-SUS 
Vex and Vey power startup is faulty. 
LOGIC 
X-SUS 
Y-SUS 
 
 
 
68 
X-SUS  Vw power voltage has dropped 
Y-SUS 
X-SUS 
LOGIC 
 
 
 
69 
 
Vw power voltage is excessive 
X-SUS 
 
 
 
6A 
 
Vw power startup is faulty. 
Y-SUS 
X-SUS 
LOGIC 
 
 
 
6C 
Vpx and Vpy voltage has dropped 
LOGIC 
X-SUS 
Y-SUS 
 
 
 
6D 
X-SUS 
Y-SUS 
Vpx and Vpy voltage is excessive 
LOGIC 
X-SUS 
Y-SUS 
 
 
 
  
 
 
 
 
-49-
 
Suspected faulty board  
(In the order of higher probability of defect)  
 
ERR 
code 
Detect 
position 
( board) 
Contents 
(1) (2) (3) (4) (5) (6) (7) 
Remarks
 
81 
PSU 
Va power voltage is excessive 
PSU 
LOGIC
 
 
 
82 
 
Va power startup is faulty. 
ADM1 - 8 PSU 
LOGIC 
ABUS-L ABUS-R
 
 
99 
 
Va power current is excessive (during operation) ADM1 - 8 ABUS-L ABUS-R PSU 
LOGIC 
 
 
9B 
 
Va power current is excessive (during startup) 
ADM1 - 8 ABUS-L ABUS-R PSU 
LOGIC 
 
 
9D 
 
Va power current is excessive (during operation) ADM1 - 8 ABUS-L ABUS-R PSU 
LOGIC 
 
  Excess current is 
detected in ACCC 
operation. 
A5 
ADM1  ADM1 has abnormal heat generation. 
ADM1 
PSU 
LOGIC 
 
 
 
A9 
ADM2  ADM2 has abnormal heat generation. 
ADM2 
PSU 
LOGIC 
 
 
 
AD 
ADM3  ADM3 has abnormal heat generation. 
ADM3 
PSU 
LOGIC 
 
 
 
B1 
ADM4  ADM4 has abnormal heat generation. 
ADM4 
PSU 
LOGIC 
 
 
 
B5 
ADM5  ADM5 has abnormal heat generation. 
ADM5 
PSU 
LOGIC 
 
 
 
B9 
ADM6  ADM6 has abnormal heat generation. 
ADM6 
PSU 
LOGIC 
 
 
 
BD 
ADM7  ADM7 has abnormal heat generation. 
ADM7 
PSU 
LOGIC 
 
 
 
C5 
ADM8  ADM8 has abnormal heat generation. 
ADM8 
PSU 
LOGIC 
 
 
 
It can possibly occur 
depending on screen 
display.  
E2 
LOGIC  5V power startup is faulty. 
X-SUS 
Y-SUS 
PANEL 
PSU ABUS-L  ABUS-R  LOGIC   
E2 
PSU 
Detection error of Vs and Va voltage. 
PSU 
LOGIC
 
 
 
   
 
Page of 79