DOWNLOAD Sony KDS-50A3000 / KDS-55A3000 / KDS-60A3000 Service Manual ↓ Size: 11.41 MB | Pages: 122 in PDF or view online for FREE

Model
KDS-50A3000 KDS-55A3000 KDS-60A3000
Pages
122
Size
11.41 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kds-50a3000-kds-55a3000-kds-60a3000.pdf
Date

Sony KDS-50A3000 / KDS-55A3000 / KDS-60A3000 Service Manual ▷ View online

KDS-50A3000/55A3000/60A3000
KDS-50A3000/55A3000/60A3000
17
2-1.  USING THE REMOTE COMMANDER 
FOR ELECTRICAL ADJUSTMENTS
To adjust various set features, use the Remote Commander to put the 
set into service mode to display the service menus and categories.
Equipment Needed:
 
  Pattern Generator (with component outputs)
 
 Oscilloscope
 
 Digital multimeter
2-2. ACCESSING SERVICE ADJUSTMENT 
MODE
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a 
second of each other: 
 
DISPLAY   
Channel 
5   
Volume 
+  
  POWER .
              
Displays
Service Menus
DISPLAY
VOLUME (+)
TV POWER
JUMP
RM-YD016
Onscreen cursor
and select button
5
 
The fi rst service menu (TV) displays.
SECTION 2:  CIRCUIT ADJUSTMENTS
2-3.  VIEWING THE SERVICE MENUS
Use the Remote Commander to view the BE and Digital service menus 
options.
1.  To display the Service Menu that contains the Category you want to 
adjust, press JUMP  on the Remote Commander. 
(For a complete list of the service Categories refer to Service Menus)
CHASSIS SERVICE
000 GR  
000 
GRMD 
     0 
 
SUB         SERVICE
000 VERS
000 
MODEL 
      
 
MODEL ID: XXXXXXXXXX      
 
Press  JUMP
BEM  
 
SERVICE
BOOT: 1. 
001W00AU
MAIN:      1. 010W00AU 
 
DATA:      1. 011A00SUA  
 
NVM:      1. 011  
 
Press  JUMP
Press  JUMP
DIGITAL
001  OP 
 
000  
000  VERS
<SUB>
<DIGITAL>
SM1. 009W00AA
DM1. 103A00SA
SD1. 003W00AA
DD0. 000A00LU
SB1. 002W00AA
<BE>
BM1. 010W00AU
BD1. 011A00SUA
BB1. 001W00AU
M2.   001C
Press  JUMP
SERVICE
Sample Service Menu
KDS-50A3000/55A3000/60A3000
KDS-50A3000/55A3000/60A3000
18
2-4.  USING THE REMOTE COMMANDER TO 
VIEW SERVICE DATA
Use the buttons on the Remote Commander to access the service menu 
items and adjust the data values.
 VCENT 
   
 
BEM  
 
SERVICE
0003 
  6 
 
0016      TG 
 
DIFF        
 
 
Service
Menu
Category
Adjustment
Item
Item 
Numbers
Data Value
RM-YD016
Display
Next Category
Display
Previous Item
 
Increase
Data Value
Decrease
Data Value
Display
Previous 
Category
Display
Next Item
Displays
Service Menus
MUTING
JUMP
Saves data
Writes data 
into memory
Read data
9
0
5
6
3
1
2
4
2-5. ADJUSTING H/V CENTER
Check the picture horizontal/vertical center after replacing the Optics 
Unit Block or Rear Cover.
1.  Check the H/V center using a 480i monoscope signal with the TV in 
“FULL’ model.
2.  If the center is shifted, proceed to step 3.
3.  Access the Service Menu by pressing the following buttons on the 
Remote Commander within a second:
 
DISPLAY   
Channel 
5   
Volume 
+  
  TV POWER .
 
The service menu displays.
4. Press the 
 JUMP
 button until the BEM micro service menu displays. 
BEM  
 
SERVICE
BOOT: 1. 
001W00AU
MAIN:      1. 010W00AU 
 
DATA:      1. 011A00SUA  
 
NVM:      1. 011  
 
5. Press 2  until the 0016 TG category displays.
BEM  
 
SERVICE
0001         
 
 
0016      TG 
 
DIFF        
 
 
6. Press 1  until the 0003 VCENT item displays.
 VCENT 
   
 
BEM  
 
SERVICE
0003 
  6 
 
0016      TG 
 
DIFF        
 
 
7. Press 3  to increase (shift VCENT up), or press  6  to decrease the 
value (shift VCENT down) until the correct adjustment is set.
8. Press 1  until the 0004 HCENT item displays.
0004 
  5 
 
 HCENT 
   
 
BEM  
 
SERVICE
0016      TG 
 
DIFF        
 
 
9. Press 3  to increase (shift HCENT right), or press  6  to decrease the 
value (shift HCENT left) until the correct adjustment is set.
10. To write into memory, press  MUTING  then  0  on the Remote  
Commander.
2-6.  EXITING SERVICE MODE
After completing the changes, exit service mode.
1.  To exit service mode, turn the power off by pressing  POWER .
 
Wait 2 minutes before restarting the set to allow the fans to 
completely shut down or the Service Menu will appear on the screen.
KDS-50A3000/55A3000/60A3000
KDS-50A3000/55A3000/60A3000
19
SECTION 3:  DIAGRAMS
3-1. CIRCUIT BOARDS LOCATION
3-2.  PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
All voltages are in V.
S : Measurement impossibility.
: B+line.
: B-line.  (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by shading and 
!
 symbol are critical for safety. Replace 
only with part number specifi ed. 
The symbol 
 indicates a fast operating fuse and is displayed on the component 
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifi es per un trame et une marque 
!
 sont critiques pour la 
securite.  Ne les remplacer que par une piece portant le numero specifi e.
Le symbole 
 indique une fusible a action rapide. Doit etre remplace par une 
fusible de meme yaleur, comme maque.
NOTE: The components identifi ed by a red outline and a   mark contain confi dential 
information. Specifi c instructions must be adhered to whenever these components 
are repaired and/or replaced. 
See Appendix A: Encryption Key Components in the back of this manual. 
All capacitors are in μF unless otherwise noted. pF : μμF 50WV or 
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms.  k
Ω=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating 
electrical power, is as follows: 
Pitch : 5mm 
 
 
    Rating 
electrical 
power 
1
/
 4 
W
1
/
 4 
W in resistance, 
1
/
10 
W and 
1
/
16 
W in chip resistance.
: nonfl ammable resistor
 : fusible resistor
 : internal component
 : panel designation and adjustment for repair
 : earth ground
 : earth-chassis
All variable and adjustable resistors have characteristic curve B, 
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
Ω digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production 
tolerances.
OPTICS BLOCK ASSEMBLY
(Includes the C Board)
T
S2
H2
BC
F
A
U
G
FB1A
TUU2
H1
KDS-50A3000/55A3000/60A3000
KDS-50A3000/55A3000/60A3000
20
REFERENCE INFORMATION 
RESISTOR 
: RN  
METAL FILM
: RC 
SOLID
: FPRD  NONFLAMMABLE CARBON
: FUSE  NONFLAMMABLE FUSIBLE
: RW 
NONFLAMMABLE WIREWOUND
: RS 
NONFLAMMABLE METAL OXIDE
: RB 
NONFLAMMABLE CEMENT
:   ADJUSTMENT 
RESISTOR
COIL 
: LF-8L  MICRO INDUCTOR
CAPACITOR
: TA 
TANTALUM
: PS 
STYROL
: PP 
POLYPROPYLENE
: PT 
MYLAR
: MPS 
METALIZED POLYESTER
: MPP 
METALIZED POLYPROPYLENE
: ALB 
BIPOLAR
: ALT 
HIGH TEMPERATURE
: ALR 
HIGH RIPPLE
G
D
S
B1 E1
C2
B2 C1
E2
2
3
4
5
6
7
8
9
0
qa
qs
qf
qh
qj
qk
1
G
D
S
B2 E2
C1
B1 C2
E1
B2 E2
C1
B1 C2
E1
B2 E2
C1
B1 C2
E1
ql
B1 E1
E2
C1(B2)
C2
w;
B1
E2
C1
C2
ws
wd
(B2) 
E1
(B2) 
E1
E2
B1
C2
C1
wa
B1
E1
C2
B2
C1
E2
G
S
S
D
G
D
B1
E1
C2
B2
C1
E2
B1
E2
C2
C1(B2)
E2
B1
C1
C2
E1(B2)
C2
B1
C1
E2
E1(B2)
C2
B1
C1
E2
B2
E1
C2
Ver.1.5
Transistor 
(FET)
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Discrete semiconductot
(Chip semiconductors that are not actually used are included.)
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Source
Source
Anode
Anode
(NC)
(NC)
Cathode
Anode
Cathode
Common
Cathode
Cathode
Common
Cathode
Cathode
Common
Common
Common
Common
Cathode
Anode
Base
Emitter
Collector
Base
Emitter
Collector
Drain
Gate
Gate
Drain
Device
Printed symbol
Terminal name
Circuit
Terminal name of semiconductors in silk screen 
printed circuit (    )
Anode
Anode
Anode
Cathode
Anode
Anode
Cathode
qd
Transistor 
(FET)
Transistor 
(FET)
qg
Emitter
Collector
Base
Transistor
Source
Gate
Drain
Cathode
Anode
Anode
Cathode
Anode
Anode
*
Page of 122
Display