KDL-46/55X4500 (K)     2-5
2-2-3-2. RED LED BLINKS (Chart C)
NO
2 times
YES
See  
1) Power Error
RED LED Blinks
NO
9 times
YES
See  
7) FAN Error
NO
5 times
YES
See  
3) T-CON Error
6 times
YES
See  
4) BACK LIGHT Error
NO
8 times
YES
See  
6) AUDIO Error
13 times
YES
See  
8) Balancer Error
NO
3 times
YES
See  
2) DC_ALERT1
NO
7 times
YES
See  
5) TEMP Error
KDL-46/55X4500 (K)     2-6
1) Power Error (R ED 2 tim es blink )
This indicates POWER Error, Low B error of 12V from G6 board. TV Micro (on AU board)
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to 
Standby status.
TV Micro pin138      Normal condition : Low  /   Error case : High
TV Micro pin79        i_lb_err< 0.7V(PW_ERR_LEV)
   - Check 12V at CN 1000 on AU board. And F1001 on AU has 12V or not.
   - Check G6 board.
2) DC_ALERT1 (RED 3 times blink)
This indicates Power Error, DC_ALERT1 of REG5V from FBU board.
TV Micro (on FBU board) Pin26 detects DC_ALERT1 and shuts down chassis power to
standby status.
TV Micro Pin26      Normal condition: High  /  Error case: Low
-  Check 12V at CN1411 Pin11, Pin12 and Pn13 on FBU board.
And F7005 on FBU board has 12V or not.
- Check G6 Board.
- Check IC7132 (on FBU Board).
3) T-CON  Error (R ED 5 tim es blink )
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin128 on FBU board detects it.
BE Micro pin128   Normal condition : High  /   Error case : Low
Replace Panel module.
KDL-46/55X4500 (K)     2-7
4) B ack  Light Error (R ED 6 tim es blink )
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FBU board detects it.
BE Micro pin 78   Normal condition : High  /   Error case : Low
5) Tem p Error (R ED 7 tim es blink )
This indicates high temperature inside chassis. IC1000 on AU board Side is monitoring
temperature. IC1000 is controlled by BEM I2C.
When it happens;
   - Check chassis environment.
   - Check around IC1000 and replace AU board if temperature monitoring circuit has problem.
6) Audio Error (R ED 8 tim es blink )
This indicates Audio Error. (Protection)
 It happens;
   - Error of  Speakers and Harness.
Check Voltage at CN1002 20pin on AU board. ( Low = Normal , High= Error)
   - Low Voltage at IC1800 [ Audio_Vcc(=12V) , A9V , D3.3V ]
   - Error of IC1800
Replace AU board.
.
 .
KDL-46/55X4500 (K)     2-8
7) FAN  Error (R ED 9 tim es blink )
This indicates  FAN error. (except 40 inch model)
BE micro pin154 on FBU board detects it.
BE Micro pin154   Normal condition : Low / Error case : High
   - Check the harnessconnection of FAN.
   - Check the Voltage at CN1301 on AU board. ( Low = Error , High = Normal)
Replace the FAN. 
8) B alancer Error (R ED 13 tim es blink )
This indicates Inverter board error of panel module.
BE micro pin163 on FBU board detects it.
BE Micro pin163    Normal condition : High / Error case : Low
46”, 55”: Check harness connection between CN 9700, 9701 on CB1 board and panel
               module.