Sony KDL-40VE5 / KDL-46VE5 / KDL-52VE5 Service Manual ▷ View online
25
KDL-40VE5/46VE5/52VE5
KDL-40VE5/46VE5/52VE5
2-1. VIEWING SERVICE ADJUSTMENT DATA
There are no adjustments necessary for these models. All data has
been set for optimal viewing for our customers. The following sections
are for informational purposes only.
been set for optimal viewing for our customers. The following sections
are for informational purposes only.
2-2. ACCESSING SERVICE MODE
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a
second of each other:
DISPLAY
Channel
5
Volume
+
POWER .
TOOLS
WIDE
INPUT
CC
DISPLAY
POWER
POWER
Onscreen cursor
and select button
and select button
DISPLAY
RM-YD028
5
VOLUME+
JUMP
SECTION 2: SERVICE ADJUSTMENTS
The
logo displays momentarily, then the Service Mode
list displays.
Service/ADC Auto Calibration
Version: ER2.6-C121 DTT: S255.P033.S077
Model: 40VE5
Serial : 8000016
Power on Time: 00000H
Model: 40VE5
Serial : 8000016
Power on Time: 00000H
Diagnostic and Serial Update
ADC Auto Calibration
Clone User Setting
Direct Log to USB
Factory Default
Clone User Setting
Direct Log to USB
Factory Default
RETURN
Change Back
Exit
2-2-1. ENTERING THE SERIAL NUMBER
AFTER CHANGING THE MAIN BOARD
Use the following instructions to re-enter the Serial Number of the TV
after replacing the Main (BM3) Board.
after replacing the Main (BM3) Board.
1. After accessing service mode, press
to display the Self Diagnostic
list.
Service Mode/Product Information
Version: ER2.6-C121 DTT: S255.P033.S077
Model: 40VE5
Power on Time: 00000H
Model: 40VE5
Power on Time: 00000H
Serial : 8000016
Diagnostic Information
2-MAIN POWER:
1
3-DC ALERT1:
0
4-TCON: 0
5-HDMI:
5-HDMI:
0
6-Backlight:
0
7-TEMP: 0
8-HFR:
8-HFR:
0
101-WDT:
0
RETURN
Change Back
Exit
2. To change the serial number fi eld, press
then using the number
keys on the remote enter the Serial Number of the TV.
3. To save the Serial Number, press
.
4. To exit Service Mode, press
.
26
KDL-40VE5/46VE5/52VE5
KDL-40VE5/46VE5/52VE5
2-2-2. RESETTING TO FACTORY DEFAULTS
1. After accessing service mode, press the
button to highlight
Factory Default, then press
.
Service/ADC Auto Calibration
Version: ER2.6-C121 DTT: S255.P033.S077
Model: 40VE5
Serial : 8000016
Power on Time: 00000H
Model: 40VE5
Serial : 8000016
Power on Time: 00000H
Diagnostic and Serial Update
ADC Auto Calibration
Clone User Setting
Direct Log to USB
ADC Auto Calibration
Clone User Setting
Direct Log to USB
Factory Default
RETURN
Change Back
Exit
Service/ADC Auto Calibration
Version: ER2.6-C121 DTT: S255.P033.S077
Model: 40VE5
Serial : 8000016
Power on Time: 00000H
Model: 40VE5
Serial : 8000016
Power on Time: 00000H
Diagnostic
and Serial Update
ADC Auto
Calibration
Clone User Setting
Direct Log to USB
Direct Log to USB
Factory Default
RETURN
Change Back
Exit
YES
NO
2. To reset to Factory Defaults, press
then follow the on-screen
instructions.
3. After selecting the language preference the on-screen display
indicates to “select the type of use for this TV.” Home must be
selected for optimal picture performance in the customers
home.
selected for optimal picture performance in the customers
home.
4. Continue following the on-screen instructions.
NOTE: All other Service Mode information listed, ADC Auto
Calibration, Clone User Setting, and Direct Log to USB will be
reviewed in the Training Manual for these models.2-1. Viewing
Service Adjustment Data
Calibration, Clone User Setting, and Direct Log to USB will be
reviewed in the Training Manual for these models.2-1. Viewing
Service Adjustment Data
27
KDL-40VE5/46VE5/52VE5
KDL-40VE5/46VE5/52VE5
SECTION 3: DIAGRAMS
3-1. CIRCUIT BOARDS LOCATION
3-2. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
All voltages are in V.
S : Measurement impossibility.
: B+line.
: B-line. (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by shading and
!
symbol are critical for safety. Replace
only with part number specifi ed.
The symbol
indicates a fast operating fuse and is displayed on the component
side of the board. Replace only with fuse of the same rating as marked.
Les composants identifi es per un trame et une marque
!
sont critiques pour la
securite. Ne les remplacer que par une piece portant le numero specifi e.
Le symbole
indique une fusible a action rapide. Doit etre remplace par une
fusible de meme yaleur, comme maque.
NOTE: The components identifi ed by a red outline and a mark contain confi dential
information. Specifi c instructions must be adhered to whenever these components
are repaired and/or replaced.
See Appendix A: Encryption Key Components in the back of this manual.
information. Specifi c instructions must be adhered to whenever these components
are repaired and/or replaced.
See Appendix A: Encryption Key Components in the back of this manual.
All capacitors are in μF unless otherwise noted. pF : μμF 50WV or
less are not indicated except for electrolytics and tantalums.
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms. k
Ω=1000Ω, MΩ=1000kΩ
Indication of resistance, which does not have one for rating
electrical power, is as follows:
electrical power, is as follows:
Pitch : 5mm
Rating
electrical
power
:
1
/
4
W
1
/
4
W in resistance,
1
/
10
W and
1
/
16
W in chip resistance.
: nonfl ammable resistor
: fusible resistor
: internal component
: panel designation and adjustment for repair
: earth ground
: earth-chassis
All variable and adjustable resistors have characteristic curve B,
unless otherwise noted.
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
Ω digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production
tolerances.
tolerances.
SWITCH UNIT
POWER SWITCH
HLR4
HMR
HSR
BM3
IP3N
28
KDL-40VE5/46VE5/52VE5
KDL-40VE5/46VE5/52VE5
G
D
S
B1 E1
C2
B2 C1
E2
2
3
4
5
6
7
8
9
–
1
G
D
S
B2 E2
C1
B1 C2
E1
B2 E2
C1
B1 C2
E1
B2 E2
C1
B1 C2
E1
B1 E1
E2
C1(B2)
C2
B1
E2
C1
C2
(B2)
E1
(B2)
E1
E2
B1
C2
C1
B1
E1
C2
B2
C1
E2
G
S
S
D
G
D
B1
E1
C2
B2
C1
E2
B1
E2
C2
C1(B2)
E2
B1
C1
C2
E1(B2)
C2
B1
C1
E2
E1(B2)
C2
B1
C1
E2
B2
E1
C2
Ver.1.6
Transistor
(FET)
(FET)
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Discrete semiconductor
(Chip semiconductors that are not actually used are included.)
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Diode
Source
Source
Anode
Anode
(NC)
(NC)
Cathode
Anode
Cathode
Common
Cathode
Cathode
Common
Cathode
Cathode
Common
Common
Common
Common
Cathode
Anode
Base
Emitter
Collector
Base
Emitter
Collector
Drain
Gate
Gate
Drain
Device
Printed symbol
Terminal name
Circuit
Terminal name of semiconductors in silk screen
printed circuit ( )
Anode
Anode
Anode
Cathode
Anode
Anode
Cathode
Transistor
(FET)
(FET)
Transistor
(FET)
(FET)
Emitter
Collector
Base
Transistor
Source
Gate
Drain
Cathode
Anode
Anode
Cathode
Anode
Anode
*
18
11
17
16
15
14
13
12
10
21
20
19
23
22
REFERENCE INFORMATION
RESISTOR
: RN
: RN
METAL FILM
: RC
SOLID
: FPRD NONFLAMMABLE CARBON
: FUSE NONFLAMMABLE FUSIBLE
: RW
: FUSE NONFLAMMABLE FUSIBLE
: RW
NONFLAMMABLE WIREWOUND
: RS
NONFLAMMABLE METAL OXIDE
: RB
NONFLAMMABLE CEMENT
: ADJUSTMENT
RESISTOR
COIL
: LF-8L MICRO INDUCTOR
: LF-8L MICRO INDUCTOR
CAPACITOR
: TA
: TA
TANTALUM
: PS
STYROL
: PP
POLYPROPYLENE
: PT
MYLAR
: MPS
METALIZED POLYESTER
: MPP
METALIZED POLYPROPYLENE
: ALB
BIPOLAR
: ALT
HIGH TEMPERATURE
: ALR
HIGH RIPPLE
Click on the first or last page to see other KDL-40VE5 / KDL-46VE5 / KDL-52VE5 service manuals if exist.