Sony KDL-32EX725 / KDL-40EX725 / KDL-46EX725 / KDL-55EX725 Service Manual ▷ View online
KDL-32EX725/40EX725/46EX725/55EX725 35
SECTION 4 - TROUBLESHOOTING
If there is no backlight before the TV shuts off and activates a 6X,
than check the Backlight ON signal from the TV microprocessor and
the Positive (+145V) Backlight power supply from the Power Supply
Board. The BL-ON signal can be checked at CN6704/pin 5 and the
+145V at CN6701/pins 1 & 3.
If the Backlight-ON signal is okay and the Positive Power supply
If the Backlight-ON signal is okay and the Positive Power supply
is missing then the Power Supply Board is defective. However, if
the Backlight-ON is missing then the X-Reality Microprocessor is
defective and the Main Board must be replaced to repair the problem.
7X Blink - Temperature Failure
These models do not display a temperature warning OSD dialogue
7X Blink - Temperature Failure
These models do not display a temperature warning OSD dialogue
box before shutting off and going into a 7X standby LED blink pattern.
The main objective when a 7X blink pattern occurs is to determine
which of the following possible defects is causing the excessive
temperature condition indication.
● Excessive Ambient Room Temperature
● Dust or Debris Blocking the TV Ventilation Apertures
● Defective Temperature Sensor or X-Reality Microprocessor
(Main Board)
The first step is to notice how long it takes the TV to shut off and
trigger a 7X blink protection mode.
If the TV has an actual excessive temperature condition it will
If the TV has an actual excessive temperature condition it will
take a considerable period of time to shut off and indicate a 7X
blink protection mode. This is because it will take time for the TV
components to heat up and for the temperature sensor to detect the
excessive temperature and shut the TV off.
If the TV takes a considerable period of time to shut-off check the
following items:
● The TV should not be located too close to any heating
devices.
● The TV should have at least 4 inches of clearance around
the sides & rear, and 11 inches of clearance over the top to
ensure adequate ventilation.
● Check that all vented areas on the TV are clear of all dust
and debris.
● If the TV shuts off immediately after Power-ON then one
of the following components has failed (Not an Actual
Excessive Temperature Condition).
● X-Reality Microprocessor (Main Board)
● Temperature Sensor (Main Board)
In either case the Main Board must be replaced to fix the
problem.
8X Blink – Not listed in Self Check
8X blink code is mainly used during TV software development. Look
8X blink code is mainly used during TV software development. Look
in TV’s service SELF CHECK for error code history and notice at the
bottom of the list WDT (Watch Dog Timer) error codes, in particular
notice 103 HOST_WDT.
10X Blink – IR Sync Transmitter Failure
A failure of the infrared sync transmitter circuits on the HEM2 board
A failure of the infrared sync transmitter circuits on the HEM2 board
will cause a 10X error and replacement of this board will usually
rectify the problem. In rare cases, the main board could be the
source of the failure.
KDL-32EX725/40EX725/46EX725/55EX725 36
SECTION 4 - TROUBLESHOOTING
DIAGNOSTIC CODE DESCRIPTIONS
The Diagnostic Table provides an overview of the number of times the standby LED blinks and the possible location.
Diagnostic Item
Diagnostic Item
Description
Number of times
Standby LED blinks
Possible Location
MAIN_POWER
Main Power Error
2
G10 Board (32" Models Only)
G4 Board (40" Models Only)
G5 Board (46" Models Only)
G6 Board (55" Models Only)
G8 Board (55" Models Only)
DC_ALERT
DC Regulator/Audio Error
AUD_PROT
Audio Error Detection
BALANCER
Balancer Error
4
LD Board
LCD Panel
T-CON ERR
T-CON Error
P_ID_ERR
Panel ID NVM Error
BACKLITE
Backlight Error
6
G10 Board (32" Models Only)
G4 Board (40" Models Only)
G5 Board (46" Models Only)
G6 Board (55" Models Only)
G8 Board (55" Models Only)
TEMP_ERR
Temperature Error
7
Ventilation
BATV Board
103 HOST_WDT
Watch Dog Timer Notification
8
Service Bulletin (See Appendix Section)
Software Update
EMITTER
Emitter Error
10
HEM2 Board
3
BATV Board
5
TCON Control MT Board
FIGURE 4-3. DIAGNOSTIC TABLE
KDL-32EX725/40EX725/46EX725/55EX725 37
SECTION 4 - TROUBLESHOOTING
VIEWING THE SELF CHECK DIAGNOSTIC HISTORY
It is possible to bring up past occurrences of a failure for confirmation
on the Self Check diagnostic history screen. This feature is useful for
failures which are intermittent or when the customer is not sure what
is causing the television to shut down.
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander
within a second of each other:
DISPLAY
Channel 5
Volume -
POWER
* NOTE: This differs from accessing Service Adjustments Mode
(Volume +)
Total operation time by hour (MAX:65535)
Boot count (MAX:65535)
Panel operation time by hour (MAX:65535)
Total operation time by hour (MAX:65535)
Boot count (MAX:65535)
Panel operation time by hour (MAX:65535)
-------------- -------------- -------------- 01
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
002 MAIN_POWE
003 DC_ALERT
003 AUD_PROT
004 BALANCER
005 HFR_ERR
005 P_ID_ERR
12345-00333-06789
12345
-
00333
-
06789
-
-
-------------- -------------- -------------- 00
006 VLED
-------------- -------------- -------------- 00
005 TCON_ERR
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
006 BACKLITE
007 TEMP_ERR
010 EMITTER
-------------- -------------- -------------- 00
007 FAN_ERR
-------------- -------------- -------------- 00
012 IA
-------------- -------------- -------------- 00
SELF CHECK
StandBy LED Flash Count
Diagnostic Item
Diagnostic Item
Error Count
(00-99)
-------------- -------------- -------------- 00
-------------- -------------- -------------- 00
101 VPC_WDT
-------------- -------------- -------------- 00
102 MEPS_WDT
-------------- -------------- -------------- 00
103 HOST_WDT
-------------- -------------- -------------- 00
104 STBY_WDT
-------------- -------------- -------------- 00
000 RGB_SEN
000 RESERVED
000 RESERVED
FIGURE 4-3. SAMPLE SELF CHECK DIAGNOSIS PAGE
CLEARING THE SELF CHECK DIAGNOSTIC LIST
Since the diagnostic results displayed on the screen are not
automatically cleared, always check the self-diagnostic screen after
you have completed the repairs to be sure you have cleared the
result display to 0.
1. To clear the Error history and Error count
press
8
0
.
RESETTING THE LCD PANEL OPERATING HOURS
The 3 sets of numbers displayed on the lower left corner of the screen
indicates the total accumulated operating hours of the television and
the operating hours of the LCD panel. Total operating hours is on the
left, boot count in the center and panel hours in the right group (The
center numbers are not used.)
1. To clear the LCD Panel operating hours of the LCD
Panel after replacing the panel, press
7
0
.
EXITING THE SELF CHECK DIAGNOSTIC SCREEN
1. To exit the Self Diagnostic screen, turn off the power to
the TV by pressing the
POWER
button on the remote
or the
POWER
button on the TV.
KDL-32EX725/40EX725/46EX725/55EX725 38