DOWNLOAD Sony KDL-32EX340 / KDL-42EX440 / KDL-42EX441 Service Manual ↓ Size: 2.21 MB | Pages: 43 in PDF or view online for FREE

Model
KDL-32EX340 KDL-42EX440 KDL-42EX441
Pages
43
Size
2.21 MB
Type
PDF
Document
Service Manual
Brand
Device
TV
File
kdl-32ex340-kdl-42ex440-kdl-42ex441.pdf
Date

Sony KDL-32EX340 / KDL-42EX440 / KDL-42EX441 Service Manual ▷ View online

KDL-32EX340/42EX440/42EX441 ii
CAUTION!!
These servicing instructions are for use by qualified service personnel only. 
To reduce the risk of electric shock, do not perform any servicing other than 
that contained in the operating instructions unless you are qualified to do so.
WARNING!!
An isolation transformer should be used during any service to avoid possible 
shock hazard, in case of live chassis. 
!
 
SAFETY-RELATED COMPONENT WARNING!!
There are critical components used in LCD color TVs that are important for 
safety. These components are identified with shading and 
!
 
mark on the 
schematic diagrams and the parts list. It is essential that these critical parts 
be replaced only with the part number specified in the parts list to prevent 
electric shock, fire, or other hazard.
NOTE: Do not modify the original design without obtaining written permission 
from the manufacturer or you will void the original parts and labor warranty.
ATTENTION!!
For safety reasons, component level repair of the Power Supply Boards 
and/or the Inverter Boards is prohibited. 
CAUTIONS AND WARNINGS
ATTENTION!!
Ces instructions de service sont à l’usage du personnel de service qualifié 
seulement. Pour prévenir le risque de choc électrique, ne pas faire l’entretien 
autre que celui contenu dans le Mode d’emploi à moins que vous soyez 
qualifié faire ainsi.
ALERTE!!
Afin d’eviter tout risque d’electrocution provenant d’un chássis sous tension, 
un transformateur d’isolement doit etre utilisé lors de tout dépannage. 
!
 ATTENTION AUX COMPOSANTS  
RELATIFS A LA SECURITE!!
Les  composants  identifies  par  une  trame  et  par  une  marque
 
!
 
sur les 
schemas de principe, les vues explosees et les listes de pieces sont d’une 
importance critique pour la securite du fonctionnement. Ne les remplacer 
que par des composants Sony dont le numero de piece est indique dans le 
present manuel ou dans des supplements publies par Sony. Les reglages 
de circuit dont l’importance est critique pour la securite du fonctionnement 
sont  identifies  dans  le  present  manuel.  Suivre  ces  procedures  lors  de 
chaque remplacement de composants critiques, ou lorsqu’un mauvais 
fonctionnement suspecte.
ATTENTION!!
Pour  des  raisons  de  sécurité,  Interdire  de  réparer  ou  remplacer  les 
composantes dans les blocs d’alimentation et/ou sur les modules d’inverseur.
KDL-32EX340/42EX440/42EX441 iii
CAUTIONS AND WARNINGS
SETTING UP AND CARRYING THE TV
 
Disconnect all cables when carrying the TV.
 
Carry the TV with the adequate number of people; larger size TVs require two or more people.
 
Correct hand placement while carrying the TV is very important for safety and to avoid damage.
USE CAUTION WHEN HANDLING THE LCD PANEL
When repairing the LCD panel, be sure you are grounded by using a wrist band.
When installing the LCD panel on a wall, the LCD panel must be secured using the 4 mounting holes on the rear cover. 
1.  Do not press on the panel or frame edge to avoid the risk of electric shock.
2.  Do not scratch or press on the panel with any sharp objects.
3.  Do not leave the module in high temperatures or in areas of high humidity for an extended period of time.
4.  Do not expose the LCD panel to direct sunlight.
5.  Avoid contact with water. It may cause a short circuit within the module.
6.  Disconnect the AC power when replacing the backlight or inverter circuit. 
 
(High voltage occurs at the inverter circuit at 650Vrms).
7.  Always clean the LCD panel with a soft cloth material.
8.  Use care when handling the wires or connectors of the inverter 
circuit. Damaging the wires may cause a short.
9.  Protect the panel from ESD to avoid damaging the electronic 
circuit (C-MOS).
10.  During the repair, 
DO NOT leave the Power On for more than 
1 hour while the TV is face down on a cloth
.
KDL-32EX340/42EX440/42EX441 iv
CAUTIONS AND WARNINGS
CLEANING THE LCD PANEL
CAUTION: When cleaning the TV, be sure to unplug the power cord to avoid any chance of electric shock.
Clean the cabinet of the TV with a dry soft cloth.
Wipe the LCD screen gently with a soft cloth.
 
;
Stubborn stains may be removed with a cloth slightly moistened with a solution of mild soap and warm water.
 
;
If using a chemically pretreated cloth, please follow the instruction provided on the package.
 
;
Never use strong solvents such as a thinner, alcohol or benzine for cleaning. 
 
;
Periodic vacuuming of the ventilation openings is recommended to ensure proper ventilation.
 
;
Do Not
 use paper towels, any type of abrasive pad, rags, rubber or vinyl materials to clean the screen. Using these materials could easily scratch the 
screen which may result in permanent damage.
 
;
Do Not
 use any cleaning product containing alkaline/acid cleaner, scouring powder, or volatile solvent, such as alcohol, ammonia, benzine, thinner or 
insecticide. Using any of these harsh cleaners may result in permanent damage to the screen.
 
;
Do Not 
spray water or detergent directly onto the TV screen. If liquid drips into the bottom of the screen it may cause a failure.
KDL-32EX340/42EX440/42EX441 v
CAUTIONS AND WARNINGS
SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety 
checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered 
connections. Check the entire board surface for solder splashes 
and bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or touching high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps, and 
mounting hardware have been replaced. Be absolutely certain that 
you have replaced all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
6.  Check the line cords for cracks and abrasion. Recommend the 
replacement of any such line cord to the customer.
7.  Check the antenna terminals, metal trim, “metallized” knobs, 
screws, and all other exposed metal parts for AC leakage. Check 
leakage as described in “Leakage Test”.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all 
exposed metal parts to any exposed metal part having a return to chassis, 
must not exceed 0.5 mA (500 microamperes). Leakage current can be 
measured by any one of three methods.
1.  A commercial leakage tester.  
Follow the manufacturers’ instructions provided with the tester.
2.  A battery-operated AC milliammeter. 
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so 
analog meters must have an accurate low voltage scale. Nearly all 
battery-operated digital multimeters that have a 2 VAC range are 
suitable. (see Figure A)
To Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
Voltmeter
(0.75V)
Figure A. Use an AC voltmeter to check AC leakage.
HOW TO FIND A GOOD EARTH GROUND
The cover-plate retaining screw on most AC outlet boxes is at earth ground. 
Verify the AC outlet box retaining screw ground by connecting a 60W to 
100W incandescent (not a neon or fluorescent lamp) between the hot side of 
the receptacle and the retaining screw. Try both slots, if necessary, to locate 
the hot side on the line; the lamp should light at normal brilliance if the screw 
is at ground potential. (see Figure B)
Figure B. Checking for earth ground.
Trouble Light
AC Outlet Box
Page of 43
Display

Click on the first or last page to see other KDL-32EX340 / KDL-42EX440 / KDL-42EX441 service manuals if exist.