DOWNLOAD Sony KDL-22EX425 / KDL-32EX425 / KDL-32EX525 / KDL-40EX525 / KDL-46EX525 (serv.man2) Service Manual ↓ Size: 23.52 MB | Pages: 96 in PDF or view online for FREE

Model
KDL-22EX425 KDL-32EX425 KDL-32EX525 KDL-40EX525 KDL-46EX525 (serv.man2)
Pages
96
Size
23.52 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / LEVEL 3
File
kdl-22ex425-kdl-32ex425-kdl-32ex525-kdl-40ex525-kd.pdf
Date

Sony KDL-22EX425 / KDL-32EX425 / KDL-32EX525 / KDL-40EX525 / KDL-46EX525 (serv.man2) Service Manual ▷ View online

5
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
SAFETY CHECK-OUT
After correcting the original service problem, perform the 
following safety checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered 
connections. Check the entire board surface for solder splashes and 
bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” or 
touching high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps, and 
mounting hardware have been replaced. Be absolutely certain that 
you have replaced all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend their 
replacement.
6.  Check the line cords for cracks and abrasion. Recommend the 
replacement of any such line cord to the customer.
7.  Check the antenna terminals, metal trim, “metallized” knobs, screws, 
and all other exposed metal parts for AC leakage. Check leakage as 
described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground 
and from all exposed metal parts to any exposed metal part 
having a return to chassis, must not exceed 0.5 mA (500 
microamperes). Leakage current can be measured by any one of 
three methods.
1.  A commercial leakage tester. Follow the manufacturers’ instructions.
2.  A battery-operated AC milliampmeter. 
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so 
analog meters must have an accurate low voltage scale. Nearly all 
battery-operated digital multimeters that have a 2 VAC range are 
suitable. (see Figure A)
To Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
Voltmeter
(0.75V)
Figure A. Use an AC voltmeter to check AC leakage.
HOW TO FIND A GOOD EARTH GROUND
The cover-plate retaining screw on most AC outlet boxes is at 
earth ground. Verify the AC outlet box retaining screw ground 
by connecting a 60-to 100-watt trouble-light (not a neon lamp) 
between the hot side of the receptacle and the retaining screw. 
Try both slots, if necessary, to locate the hot side on the line; the 
lamp should light at normal brilliance if the screw is at ground 
potential. (see Figure B)
Figure B. Checking for earth ground.
Trouble Light
AC Outlet Box
6
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
The circuit boards used in these models have been processed using 
Lead Free Solder. The boards are identified by the LF logo located 
close to the board designation e.g. H1 etc [ see example ]. The 
servicing of these boards requires special precautions to be taken as 
outlined below. 
example
It is strongly recommended to use Lead Free Solder material in order to guarantee optimal quality of new solder joints.  
Lead Free Solder is available under the following part numbers : 
Due to the higher melting point of Lead Free Solder the soldering iron tip temperature needs to be set to 370 degrees celsius. 
This requires soldering equipment capable of accurate temperature control coupled with a good heat recovery characteristics.
7
0
7
0
7
0
7
0
7
0
7
1
7
1
7
1
7
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
SECTION 1:  DIAGRAMS
1-1.  CIRCUIT BOARDS LOCATION
SWITCH
UNIT
HLR2
HMS3
G1
TCON
BATV
Figure 1-1.  KDL-22EX425
SWITCH
UNIT
HLR2
HMS3
GE2
TCON
BATV
Figure 1-2.  KDL-32EX425/32EX525
8
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
KDL-22EX425/32EX425/32EX525/40EX525/46EX525
SWITCH
UNIT
HLR2
HMS3
GE3
TCON
BATV
Figure 1-3.  KDL-40EX525
SWITCH
UNIT
HLR2
HMS3
GE3
TCON
BATV
Figure 1-4.  KDL-46EX525
Page of 96
Display

Click on the first or last page to see other KDL-22EX425 / KDL-32EX425 / KDL-32EX525 / KDL-40EX525 / KDL-46EX525 (serv.man2) service manuals if exist.