Sony KDL-15G2000 / KDL-20G2000 Service Manual ▷ View online
- 5 -
SE-1
RM-ED007
How to replace the fuse.
Open the fuse compartment with
a screwdriver blade and replace
the fuse.
Open the fuse compartment with
a screwdriver blade and replace
the fuse.
FUSE
WARNING (UK Models only)
The flexible mains lead is supplied connected to a B.S. 1363 fused
plug having a fuse of 5 AMP rating. Should the fuse need to be
replaced, use a 5AMP FUSE approved by ASTA to BS 1362, ie one
that carries the
plug having a fuse of 5 AMP rating. Should the fuse need to be
replaced, use a 5AMP FUSE approved by ASTA to BS 1362, ie one
that carries the
ASA
T
mark.
IF THE PLUG SUPPLIED WITH THIS APPLIANCE IS NOT SUIT-
ABLE FOR THE OUTLET SOCKETS IN YOUR HOME, IT SHOULD
BE CUT OFF AND AN APPROPRIATE PLUG FITTED. THE PLUG
SEVERED FROM THE MAINS LEAD MUST BE DESTROYED AS A
PLUG WITH BARED WIRES IS DANGEROUS IF ENGAGED IN A
LIVE SOCKET.
ABLE FOR THE OUTLET SOCKETS IN YOUR HOME, IT SHOULD
BE CUT OFF AND AN APPROPRIATE PLUG FITTED. THE PLUG
SEVERED FROM THE MAINS LEAD MUST BE DESTROYED AS A
PLUG WITH BARED WIRES IS DANGEROUS IF ENGAGED IN A
LIVE SOCKET.
When an alternative type of plug is used, it should be fitted with a
5 AMP FUSE, otherwise the circuit should be protected by a 5 AMP
FUSE at the distribution board.
5 AMP FUSE, otherwise the circuit should be protected by a 5 AMP
FUSE at the distribution board.
Model Name
Item
KDL-15G2000
KDL-20G2000
KDL-20G2000
(AEP)
KDL-15G2000
KDL-20G2000
KDL-20G2000
(UK)
PAP
OFF
OFF
PAT
OFF
OFF
RGB Priority
ON
ON
Sub Woofer
OFF
OFF
Scart 1
ON
ON
Scart 2
ON
ON
Front in (3) (KDL-15G2000)
Front in (4) (KDL-20G2000)
Front in (4) (KDL-20G2000)
ON
ON
Projector
OFF
OFF
Norm B/G
ON
OFF
Norm I
ON
ON
Norm D/K
ON
OFF
Norm AUS
OFF
OFF
Norm L
ON
OFF
Norm SAT
OFF
OFF
Norm M
OFF
OFF
Teletext
ON
ON
Nicam Stereo
ON
ON
- 6 -
SE-1
RM-ED007
21 pin connector
19
17
15
13
11
9
7
5
3
1
20
18
16
14
12
10
8
6
4
2
21
Rear Connection Panel
Side Connection Panel
n
o
i
t
a
r
u
g
i
f
n
o
c
n
i
p
t
e
k
c
o
s
o
e
d
i
V
S
n
i
P
o
N
l
a
n
g
i
S
l
e
v
e
L
l
a
n
g
i
S
1
d
n
u
o
r
G
-
2
d
n
u
o
r
G
-
3
t
u
p
n
i
)
l
a
n
g
i
s
S
(
Y
,
m
h
o
5
7
B
d
3
-
/
+
V
1
V
3
.
0
.
c
n
y
S
e
v
i
t
i
s
o
p
B
d
0
1
+
3
-
4
t
u
p
n
i
)
l
a
n
g
i
s
S
(
C
B
d
3
-
/
+
V
3
.
0
e
v
i
t
i
s
o
p
,
m
h
o
5
7
.
c
n
y
S
S-Video
socket
_
_
Red input
0.7 +/- 3dB, 75 ohms, positive
_
(S signal Chroma
Connected
Not Connected (open) * at 20Hz - 20kHz
Pin No
1
2
Signal
Signal level
1
Audio output B
(right)
(right)
Standard level : 0.5V rms
Output impedence : Less than 1kohm*
Output impedence : Less than 1kohm*
2
Audio input B
(right)
(right)
Standard level : 0.5V rms
Output impedence : More than 10kohm*
Output impedence : More than 10kohm*
3
Audio output A
(left)
(left)
Standard level : 0.5V rms
Output impedence : Less than 1kohm*
Output impedence : Less than 1kohm*
4
Ground (audio)
5
Ground (blue)
6
Audio input A
(left)
(left)
Standard level : 0.5V rms
Output impedence : More than 10kohm*
Output impedence : More than 10kohm*
7
Blue input
0.7 +/- 3dB, 75 ohms positive
8
Function select
(AV control)
(AV control)
High state (9.5-12V) : Part mode
Low state (0-2V) : TV mode
Input impedence : More than 10K ohms
Input capacitance : Less than 2nF
Low state (0-2V) : TV mode
Input impedence : More than 10K ohms
Input capacitance : Less than 2nF
9
Ground (green)
10
AVlink
11
Green
Green signal : 0.7 +/- 3dB, 75 ohms,
positive
positive
12
Open
13
Ground (red)
14
Ground (blanking)
15
input)
0.3 +/- 3dB, 75 ohms, positive
16
Blanking input
(Ys signal)
(Ys signal)
High state (1-3V) Low state (0-0.4V)
Input impedence : 75 ohms
Input impedence : 75 ohms
17
Ground (video
output)
output)
18
Ground (video
input)
input)
19
Video output
1V +/- 3dB, 75ohms, positive sync 0.3V
(-3+10dB)
(-3+10dB)
20
Video input
1V +/- 3dB, 75ohms, positive sync 0.3V
(-3+10dB)
Video input
Y (S signal)
1V +/- 3dB, 75ohms, positive sync 0.3V
(-3+10dB)
(-3+10dB)
21
Common ground
(plug, shield)
(plug, shield)
- -
- -
KDL-15G2000
KDL-20G2000
- 7 -
SE-1
RM-ED007
SE-1 SELF DIAGNOSTIC SOFTWARE
The identification of errors within the SE-1 chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the event
of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flashing
LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number
will be displayed through the LED (Series of flashes which must be counted).
of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flashing
LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number
will be displayed through the LED (Series of flashes which must be counted).
Flash Timing Example : e.g. error number 3
StBy LED
ON
ON
OFF
OFF
LED Error Code
Error Message
LED Code
Checked
Action
Power Supply Protection Error
03
In Normal mode.
Goes into standby. LED flashes 3
times.
times.
Panel Error
04
In Normal mode.
Goes into standby. LED flashes 4
times.
times.
NVM Error
05
In Initialisation state.
Adds error to Error Menu. LED
flashes 5 times in factory mode.
flashes 5 times in factory mode.
IIC Error
06
In Initialisation state.
Adds error to Error Menu. LED
flashes 6 times in factory mode.
flashes 6 times in factory mode.
HDMI Error
07
In Initialisation state.
Adds error to Error Menu. LED
flashes 7 times in factory mode.
flashes 7 times in factory mode.
Digital Error
08
In Initialisation state.
Adds error to Error Menu. LED
flashes 8 times in factory mode.
flashes 8 times in factory mode.
Tuner Error
09
In Initialisation state.
Adds error to Error Menu. LED
flashes 9 times in factory mode.
flashes 9 times in factory mode.
Sound Processor Error
10
In Initialisation state.
Adds error to Error Menu. LED
flashes 10 times in factory mode.
flashes 10 times in factory mode.
Video Processor (VCTP) Error
11
In Initialisation state.
Adds error to Error Menu. LED
flashes 11 times in factory mode.
flashes 11 times in factory mode.
Port Expander Error
12
In Initialisation state.
Adds error to Error Menu. LED
flashes 12 times in factory mode.
flashes 12 times in factory mode.
RTC IC Error
14
In Initialisation state.
Adds error to Error Menu. LED
flashes 14 times in factory mode.
flashes 14 times in factory mode.
– 8 –
SE-1
RM-ED007
The operating instructions mentioned here are partial abstracts
from the Operating Instruction Manual. The page numbers of
the Operating Instruction Manual remain as in the manual.
SECTION 1
GENERAL
1:
Che
cki
ng
th
e
accessories
Re
m
o
te
RM
-E
D00
7
(1)
Size
AA
b
a
tt
erie
s (R6
ty
p
e
) (2
)
Su
pp
or
t
b
e
lt (1) an
d sc
re
w
s (2)
Co
ax
ia
l
ca
ble
(o
nly
for KDL
-20
G
2
0
0
0
) (1)
M
a
in
s le
ad
(T
yp
e
C-6
) (1
)
AC
ad
a
p
to
r (1
)
T
o
in
se
rt b
a
tte
rie
s in
to
th
e
re
m
o
te
No
te
s
•
O
b
ser
v
e
t
h
e
co
rr
e
ct
p
o
la
ri
ty
wh
en
in
ser
tin
g
b
a
tt
er
ie
s.
•
D
is
pose
o
f b
at
te
ri
es
in
a
n
e
nvi
ron
m
e
n
ta
ll
y
f
ri
e
ndl
y
wa
y.
Ce
rt
ai
n re
gi
o
ns m
a
y re
gul
a
te
d
ispo
sal
o
f t
he
ba
tt
ery
.
Pl
ea
se co
nsul
t yo
ur lo
ca
l a
u
th
ori
ty
.
•
D
o n
ot
use
di
ffer
en
t t
ype
s of
bat
te
ri
es t
og
et
he
r or m
ix o
ld
a
nd ne
w bat
te
ri
es
.
•
H
a
ndl
e t
h
e re
m
o
te
w
it
h
ca
re
. D
o
no
t dro
p
or ste
p
on i
t,
o
r
sp
il
l
li
q
u
id
o
f a
n
y
k
in
d
o
n
to
i
t.
•
D
o no
t pl
ac
e t
h
e
re
m
o
te
in
a
loc
a
ti
on ne
ar
a
h
ea
t sou
rce
, o
r
in
a p
la
c
e s
u
bj
ec
t
to
d
ir
ect
su
n
lig
ht
,
or
i
n
a
da
mp
r
o
om.
2: Conne
ctin
g an aerial/
VC
R
Co
nn
ect
in
g an
a
e
ri
al
on
ly
C
onn
ec
ti
n
g
an
a
e
ri
a
l a
nd V
C
R
Co
a
x
ia
l c
a
b
le
(
s
u
p
p
lie
d
o
n
ly
to
KD
L-
20G
2
0
0
0
)
S
c
a
rt
le
ad
(
n
ot
s
u
p
p
lie
d
)
F
o
r K
D
L
-1
5G
20
00
For
KDL-
20G
200
0
C
o
ax
ia
l c
abl
e
(no
t su
pp
lied
)
Co
a
x
ia
l c
a
b
le
(s
up
pl
ied on
ly
t
o
K
D
L-
20
G
200
0)
VCR
3: Bundl
in
g
th
e cabl
es
4:
Pre
venting th
e TV
from
t
opp
lin
g o
ver
(o
nly
fo
r K
D
L-
20
G20
0
0)
5:
Selecting the language
an
d country/re
gion
1
Connec
t the T
V
to y
our mains
s
oc
k
et
(220-240 V AC, 50 Hz
).
2
Pr
es
s
1
on the TV (top s
ide).
Wh
en
yo
u
switc
h
o
n
the
TV fo
r t
h
e f
irst t
im
e,
th
e
L
ang
uag
e men
u
ap
pea
rs
o
n
t
h
e
sc
reen
.
Wh
en
the
T
V
is
in
s
ta
n
db
y m
o
de
(t
he
1
(
sta
ndb
y)
in
d
ic
ato
r o
n
th
e T
V
(fro
n
t)
is red
),
p
ress
"/
1
on
th
e re
m
o
te
to
switc
h
o
n
t
h
e TV.
2
1
A
C
ada
pt
or
(s
up
pl
ie
d)
Ma
in
s
le
a
d
(s
u
p
p
lie
d
)
3,4
2
Click on the first or last page to see other KDL-15G2000 / KDL-20G2000 service manuals if exist.