-37-
 
4.7.3 Problem Analysis Procedure 
(1) Select the problem analysis menu from the main menu using the ↑key or ↓key and press 
<ENTER> key to start the program.   
(2) Check the error code (hexadecimal number) from the Latest error code read-out menu and 
locate the faulty position from the following table. 
Example of displaying breakdown analysis 
 
(3) Confirm the latest error code, and then the faulty point is specified from the Error code table.   
(4) Select RETURN using the ↑key or ↓key and press <ENTER> key to start the program, then 
the screen returns to the menu screen.   
* When EXIT is selected, the screen returns to the WINDOWS or DOS screen.   
Main menu 
Problem analysis menu 
The state of the module
The latest error code
A past error code is shown in 
new the order. 
All error code is cleared to 0.
-38-
 
Error code table
 
Suspected faulty board   
(In the order of higher probability of defect) 
ERR 
code 
Detect 
position 
(board) 
Contents 
(1) 
(2) 
(3) 
(4) 
(5) 
(6) 
(7) 
Remarks 
00 
LOGIC 
STANDBY power is stopped 
PSU 
 
 
 
 
 
 
PSU temperature 
has probably   
increased 
02 
ROM data of waveform is abnormal  LOGIC 
 
 
 
 
 
 
 
04 
3.3V power voltage has dropped 
LOGIC 
PSU 
 
 
 
 
 
 
06 
3.3V power startup is faulty 
X-SUS 
Y-SUS
ADMU1-U11
ADND1-D11
PSU 
ABUSU1-U4 
ABUSD1-D4
LOGIC  
 
08 
1V power voltage has dropped 
LOGIC 
PSU 
 
 
 
 
 
 
0A 
1V power startup is faulty 
X-SUS 
Y-SUS ADM1-22 PSU 
ABUS 
LOGIC   
 
18 
Internal 
I2C_SCL1_LOW 
level 
LOGIC 
          
19 
Internal I2C_ACK does not respond  LOGIC 
 
 
 
 
 
 
 
1C 
EEPROM initial setting is defective  LOGIC 
 
 
 
 
 
 
 
1D 
EEPROM write-down is defective 
LOGIC 
 
 
 
 
 
 
 
1E 
EEPROM user initial setting is 
defective 
LOGIC 
          
1F 
LOGIC 
EEPROM factory setting reading is 
defective 
LOGIC 
          
24 
Vex power voltage has decreased 
X-SUS 
LOGIC  
 
 
 
 
 
25 
Vex power voltage is excessive 
X-SUS 
 
 
 
 
 
 
 
26 
Vex power startup is faulty. 
X-SUS 
LOGIC  
 
 
 
 
 
28 
Vx power voltage has dropped 
X-SUS 
LOGIC  
 
 
 
 
 
29 
Vx power voltage is excessive 
X-SUS 
 
 
 
 
 
 
 
2A 
Vx power startup is faulty. 
X-SUS 
LOGIC  
 
 
 
 
 
39 
Vs power current is excessive 
(during operation) 
X-SUS Panel LOGIC  
 
 
 
 
3B 
Vs power current is excessive 
(during startup) 
X-SUS Panel LOGIC  
 
 
 
 
3C 
Vq power voltage has dropped 
X-SUS 
 
 
 
 
 
 
 
3D 
Vq power voltage is excessive 
X-SUS 
 
 
 
 
 
 
 
3E 
X-SUS 
Vq power startup is faulty. 
X-SUS 
 
 
 
 
 
 
 
44 
Vey power voltage has dropped 
Y-SUS 
LOGIC  
 
 
 
 
 
45 
Vey power voltage is excessive 
Y-SUS 
 
 
 
 
 
 
 
46 
Vey power startup is faulty. 
Y-SUS 
LOGIC  
 
 
 
 
 
48 
Vu power voltage has dropped 
Y-SUS 
 
 
 
 
 
 
 
49 
Vu power voltage is excessive 
Y-SUS 
 
 
 
 
 
 
 
4A 
Vu power startup is faulty. 
Y-SUS 
 
 
 
 
 
 
 
59 
Vs power current is excessive 
(during operation) 
Y-SUS Panel LOGIC  
 
 
 
 
5B 
Vs power current is excessive 
(during startup) 
Y-SUS Panel LOGIC  
 
 
 
 
5D 
Y-SUS 
SDM current is excessive 
SDM 
Y-SUS Panel 
LOGIC  
 
 
 
61 
Vs power voltage is excessive 
PSU 
X-SUS LOGIC 
 
 
 
 
 
62 
Vs power startup is faulty. 
X-SUS 
Y-SUS PSU 
LOGIC  
 
 
 
64 
Ve power voltage has dropped 
LOGIC 
X-SUS Y-SUS 
 
 
 
 
 
65 
Ve power voltage is excessive 
X-SUS 
Y-SUS  
 
 
 
 
 
66 
Ve power startup is faulty. 
LOGIC 
X-SUS Y-SUS 
 
 
 
 
 
68 
Vw power voltage has dropped 
Y-SUS 
X-SUS LOGIC 
 
 
 
 
 
69 
Vw power voltage is excessive 
X-SUS 
 
 
 
 
 
 
 
6A 
X-SUS 
Y-SUS 
 
Vw power startup is faulty. 
Y-SUS 
X-SUS LOGIC 
 
 
 
 
 
81 
Va power voltage is excessive   
PSU 
X-SUS LOGIC 
 
 
 
 
 
82 
Va power startup is faulty. 
ADMU1-U11
ADND1-D11
PSU X-SUS LOGIC 
ABUS  
 
 
99 
Va power current is excessive 
(during operation) 
ADMU1-U11
ADND1-D11
ABUS
X-SUS PSU LOGIC  
 
 
9B 
ABUS 
Va power current is excessive 
(during startup) 
ADMU1-U11
ADND1-D11
ABUS
X-SUS PSU LOGIC  
 
 
-39-
 
Suspected faulty board 
(In the order of higher probability of defect) 
ERR 
code 
Detect 
position 
(board) 
Contents 
Contents 
(1) 
(2) 
(3) 
(4) 
(5) 
(6) 
(7) 
Remarks 
9D 
 
Va power current is excessive (during 
operation) 
ADM1-8 ABUS PSU  
LOGIC  
 
 
Excess current is 
detected in ACCC
operation. 
A5 
ADM-D1  ADM-D1 has abnormal heat generation. ADM-D1 PSU 
LOGIC  
 
 
 
A7 
ADM-U1  ADM-U1 has abnormal heat generation. ADM-U1 PSU 
LOGIC  
 
 
 
A9 
ADM-D2  ADM-D2 has abnormal heat generation. ADM-D2 PSU 
LOGIC  
 
 
 
AB 
ADM-U2  ADM-U2 has abnormal heat generation. ADM-U2 PSU 
LOGIC  
 
 
 
AD 
ADM-D3  ADM-D3 has abnormal heat generation. ADM-D3 PSU 
LOGIC  
 
 
 
AF 
ADM-U3  ADM-U3 has abnormal heat generation. ADM-U3 PSU 
LOGIC  
 
 
 
B1 
ADM-U4  ADM-U4 has abnormal heat generation. ADM-U4 PSU 
LOGIC  
 
 
 
B3 
ADM-D4  ADM-D4 has abnormal heat generation. ADM-D4 PSU 
LOGIC  
 
 
 
B5 
ADM-U5  ADM-U5 has abnormal heat generation. ADM-U5 PSU 
LOGIC  
 
 
 
B7 
ADM-D5  ADM-D5 has abnormal heat generation. ADM-D5 PSU 
LOGIC  
 
 
 
B9 
ADM-U6  ADM-U6 has abnormal heat generation. ADM-U6 PSU 
LOGIC  
 
 
 
BB 
ADM-D6  ADM-D6 has abnormal heat generation. ADM-D6 PSU 
LOGIC  
 
 
 
BD 
ADM-U7  ADM-U7 has abnormal heat generation. ADM-U7 PSU 
LOGIC  
 
 
 
BF 
ADM-D7  ADM-D7 has abnormal heat generation. ADM-D7 PSU 
LOGIC  
 
 
 
C5 
ADM-U8  ADM-U8has abnormal heat generation. ADM-U8 PSU 
LOGIC  
 
 
 
C7 
ADM-D8  ADM-D8 has abnormal heat generation. ADM-D8 PSU 
LOGIC  
 
 
 
C9 
ADM-U9  ADM-U9has abnormal heat generation. ADM-U9 PSU 
LOGIC  
 
 
 
CB 
ADM-D9  ADM-D9 has abnormal heat generation. ADM-D9 PSU 
LOGIC  
 
 
 
CD ADM-U10 
ADM-U10has 
abnormal 
heat 
generation. 
ADM-U10 PSU LOGIC  
 
 
 
CF 
ADM-D10  ADM-D10 has abnormal heat 
generation. 
ADM-D10 PSU LOGIC  
 
 
 
D1 ADM-U11 
ADM-U11has 
abnormal 
heat 
generation. 
ADM-U11 PSU LOGIC  
 
 
 
D3 
ADM-D11  ADM-D11 has abnormal heat 
generation. 
ADM-D11 PSU LOGIC  
 
 
 
E2 
LOGIC 
5V power startup is faulty. 
X-SUS 
Y-SUS PANEL PSU 
ABUS 
LOGIC   
FC 
PSU 
Detection error of Vs and Va voltage. 
PSU 
LOGIC  
 
 
 
 
It can possibly 
occur depending 
on screen display. 
 
-40-
 
5 DISASSEMBLING AND REASSEMBLING 
Unless otherwise specified, use the torque screwdriver for screw tightening, following the 
tightening torques. 
Screw size 
Tightening torque 
M 3 
0.69±0.049Nm (7±0.5kg·cm) 
M 4 
1.18±0.098Nm (12±1.0kg·cm) 
 
5.1 Exploded View 
   
 
   
 
   
 
 
 
 
 
 
 
 
 
 