Sony KD-34XBR2 Service Manual ▷ View online
— 10 —
KD-34XBR2
1
Discharge the anode of the CRT and remove the anode cap.
2
Unplug all interconnecting leads from the defl ection yoke, neck
assembly, degaussing coils and CRT grounding strap.
3
Remove the C Board from the CRT.
4
Remove the chassis assembly.
5
Loosen the neck assembly fi xing screw and remove.
6
Loosen the defl ection yoke fi xing screw and remove.
7
Remove (2) screws from the degaussing coil holder assemblies to
release the CRT grounding strap.
8
Place the set with the CRT face down on a cushion and remove
the degaussing coil holders.
9
Remove the CRT supports (on both left and right sides) by lifting
up on the clip and gently sliding it up and out.
10
Remove (4) screws holding in the Spacer -36 at the top of the
cabinet and remove, making sure to remove the degaussing coil
holders with it.
holders with it.
1-3. PICTURE TUBE REMOVAL
WARNING: BEFORE REMOVING THE ANODE CAP
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock,
discharge CRT before attempting to remove the anode cap. Short between anode and CRT
coated earth ground strap.
High voltage remains in the CRT even after the power is disconnected. To avoid electric shock,
discharge CRT before attempting to remove the anode cap. Short between anode and CRT
coated earth ground strap.
Coated
Earth
Ground
Strap
1
2
3
4
5
6
7
8
9
10
11
12
13
14
INCORRECT
CORRECT
11
Remove the degaussing coil.
12
Remove the CRT grounding strap and tension springs.
13
Unscrew the four CRT fi xing screws [located on each CRT corner]
and remove the CRT [Take care not to handle the CRT by the
neck assembly.]
neck assembly.]
NOTE: The CRT screws used with the HA3 are specifi c to this unit. If
replacement is necessary, these exact screws must be used.
(p/n: 4-080-811-01; Desc: SCREW, TAPPING (7) + CROWN WASHER)
14
IMPORTANT: When replacing the CRT, care must be taken in
replacing the CRT spacers into the cabinet. The spacer must be
completely reset prior to re-inserting the CRT screws (see fi gure
above for proper setting of CRT spacer).
completely reset prior to re-inserting the CRT screws (see fi gure
above for proper setting of CRT spacer).
NOTE:
When removing the screws from the CRT, damage occurs to the
CRT Spacer. It is necessary to replace these components after
removal.
removal.
(p/n: 4-080-267-01; Desc: Spacer, CRT)
— 11 —
KD-34XBR2
1-4. SERVICE POSITION
1
1
Leaving the boards intact in the Main
Bracket, pull up and rotate both the A and
D boards in order to service the unit.
D boards in order to service the unit.
ANODE CAP REMOVAL PROCEDURE
WARNING: High voltage remains in the CRT even after the power is disconnected. To avoid electric shock, discharge CRT before attempting to remove
the anode cap. Short between the anode and CRT coated earth ground strap.
the anode cap. Short between the anode and CRT coated earth ground strap.
NOTE: After removing the anode cap, short circuit to either the metal chassis, CRT shield, or carbon painted on the CRT.
REMOVAL PROCEDURES
Turn up one side of the rubber cap in the
direction indicated by arrow a .
Use your thumb to pull the rubber cap fi rmly
in the direction indicated by arrow
b
.
When one side of the rubber cap separates
from the anode button, the anode cap can
be removed by turning the rubber cap and
be removed by turning the rubber cap and
pulling it in the direction of arrow c .
HOW TO HANDLE AN ANODE CAP
1. Do not use sharp objects which may cause damage to the surface of the anode
cap.
2. To avoid damaging the anode cap, do not squeeze the rubber covering too hard.
A material fi tting called a shatter-hook terminalis built into the rubber.
3. Do not force turn the foot of the rubber cover. This may cause the shatter-hook
terminal to protrude and damage the rubber.
Anode Button
c
a
b
— 12 —
KD-34XBR2
SECTION 2: MECHANICAL PRE-ADJUSTMENTS
2-1. RING MAGNET ADJUSTMENTS
Location of ring magnets for adjustment:
Purity Magnet
BMC Magnet
V. STAT Magnet
PURITY MAGNETS
Adjust the purity magnets so that the adjusting tabs are straight up.
Adjust the purity magnets so that the adjusting tabs are straight up.
Purity
Magnets
Magnets
V-STAT MAGNETS
Adjust the V-Stat Magnets so that the adjustment tabs are approximately
± 45° from 0° (a total of 90° between each tab)
Adjust the V-Stat Magnets so that the adjustment tabs are approximately
± 45° from 0° (a total of 90° between each tab)
NOTE:
The
points
( 1 ) on the edges of each tab should be
evenly aligned (see the fi gure below).
V-STAT
Magnet
Magnet
0˚
+45˚
-
45˚
1
BMC MAGNETS
Adjust the BMC Magnets so that the adjustment tabs are approximately
± 40° from 90°.
Adjust the BMC Magnets so that the adjustment tabs are approximately
± 40° from 90°.
NOTE: The rounded points ( 1 ) on the edges of each tab should
be evenly aligned (see the fi gure next column).
IMPORTANT:
Make sure that the following items are checked and adjusted
whenever the CRT or Defl ection Yoke have been replaced.
whenever the CRT or Defl ection Yoke have been replaced.
BMC
Magnet
Magnet
1
90˚
130˚
50˚
2-2. NECK ASSEMBLY POSITIONING
1. The left and right sides of the neck assembly must be straight up
and down.
2. Make sure that the rear edge of the plastic fl ange on the neck
assembly is positioned directly above the edge of the CRT pin
electrodes that are soldered to G1 within the neck of the CRT (see
electrodes that are soldered to G1 within the neck of the CRT (see
1 below)
G1
Neck Ass'y
Flange
Flange
CRT/Neck
Assembly
Top View
Assembly
Top View
Proper
Alignment
(Top View of
CRT Neck)
Alignment
(Top View of
CRT Neck)
Improper
Alignment
Alignment
Flange Too
Far Foreward
Flange Too
Far Rearward
Electrodes
CRT Neck
Neck
Ass'y
Flange
Ass'y
Flange
1
— 13 —
KD-34XBR2
SECTION 3: BEAM LANDING AND RASTER CENTER ADJUSTMENTS
3-1. BEAM LANDING ADJUSTMENT
REQUIRED EQUIPMENT:
NTSC Video Pattern Generator (into VIDEO-1 input)
Landing Magnets (for correcting mislanding in the corners of the set)
SET-UP CONDITION:
DISPLAY
DISPLAY
MODE:
FULL
VIDEO
SOURCE:
VIDEO-1
PICTURE MODE: STANDARD (select the STANDARD mode from
the menu, then press the RESET button on the remote control to set
the STANDARD settings to the factory settings.)
the menu, then press the RESET button on the remote control to set
the STANDARD settings to the factory settings.)
TILT CORRECTION: Set to 0 (Zero)
VERTICAL CORRECTION: Set to 0 (Zero)
PICTURE TUBE POSITION: Face in an East or West Direction**
**Note: Typically, adjustments will be made to this unit while it
is in its normal position in a customer’s home. Any
directional references made in this manual should only
be followed when the unit is being serviced elsewhere
(e.g. in a shop).
directional references made in this manual should only
be followed when the unit is being serviced elsewhere
(e.g. in a shop).
PROCEDURE:
1. Turn on power to the set and make sure that the degauss circuit is in
1. Turn on power to the set and make sure that the degauss circuit is in
working order (a brief hum will sound from the degauss coils).
2. Loosen the defl ection yoke mounting screw, and set the purity
magnet adjustment tabs to the center as shown below:
Purity Magnet Adjustment Tabs
3. Input a green raster from the pattern generator.
4. Move the defl ection yoke backwards, and adjust the purity ring
magnets so that the center of the screen is green, and the red and
blue areas on either side of the screen are approximately the same
size as shown in the fi gure below:
blue areas on either side of the screen are approximately the same
size as shown in the fi gure below:
Blue
Red
Green
5. Move the defl ection yoke forward until the entire screen becomes
green.
6. Confi rm the purity for both the red and blue rasters.
7. Tighten the defl ection yoke mounting screw just enough to keep the
yoke from moving forward or backward, but not too tight as to keep
it from rotating.
it from rotating.
8. Input a crosshatch pattern from the generator. Rotate the yoke so
that the crosshatch’s top and bottom lines are as even with the
bezel as possible. Secure the defl ection yoke by fully tightening the
mounting screw.
bezel as possible. Secure the defl ection yoke by fully tightening the
mounting screw.
9. Use a DY Spacer (p/n: 4-053-005-01) between the defl ection yoke
and the CRT in order to maintain the yoke position in each axis.
10. Add disk magnets (p/n: 1-452-032-00) to the back of the CRT as
necessary to correct mislanding in the corners of the screen.
b
d
a
c
Purity control
corrects this area
Deflection yoke positioning
corrects these areas
Disk magnets
or rotatable disk
magnets correct
these areas (a-d)
This completes the beam landing adjustment.
Click on the first or last page to see other KD-34XBR2 service manuals if exist.