5
VPL-VW200
2-6. Communication Rules
. When sending a command from CONTROLLER, the return data from PROJECTOR should be re-
ceived first before sending the next command. Even if the next command is sent before receiving the
return data, since PROJECTOR will not be able to receive that command, it does not return a response
to CONTROLLER. Consequently, no error code is also sent.
The following lists the approximate waiting times for PROJECTOR to return the return data after
CONTROLLER sends the command.
. When a communication error occurs, PROJECTOR ignores the data received until now, and set into the
reception standby state.
. For undefined commands or commends determined as invalid by PROJECTOR, PROJECTOR will
send the “NAK” return data to CONTROLLER .
. Take note that when data is written when the input signal of PROJECTOR is unstable, that data (value)
will not be incorporated.
. When INDEX specified SIRCS direct command is transmitted, leave an interval of 45 msec until the
next transmission. (Do not return the return data (ACK, NAK) when the SIRCS direct command is
received.)
2-7. Approximate Return Waiting Times
The return waiting time varies between 30 and 1500 msec depending on the command.
n
This is the case, unless the communications are interfered anyway.
2-8. Other
2-8-1. AMX Device Discovery
This model is equipped with the protocol that conforms to the Device Discovery stipulated by
AMX.Contact AMX for details about the Device Discovery.
6
VPL-VW200
3.
NETWORK
This section describes the performance, operations and protocol to be used of advertisement and PJ Talk.
3-1. Advertisement
The advertisement service is provided to facilitate development of a PC application that can automatically
detect a projector on the network. This function is achieved by broadcasting the equipment information
periodically to the network.
3-1-1. Function
The equipment information shown below is transmitted as the broadcast packet periodically (at certain
intervals).
Information
Description
Category
Category of the equipment
Equipment name
Name of the equipment
Serial number
Serial number of the equipment
Installation information
Installation location of the equipment
Community
Community name of the equipment
Power status
Power status of the equipment
m
. The category of projector is 0x0a.
. The power status sets ffffh if communication error occurs.
Protocol
The SDAP protocol is defined in order to provide this service.
Item
Description
Protocol name
SDAP (Simple Display Advertisement Protocol)
Transport
UDP
Port number
53862 (Factory-shipments value)
Broadcast interval
Once every 30 seconds (Factory-shipments value)
3-1-2. Setup Items
The items that can be set for the advertisement service are described below.
Setup items
Description
Port No.
Port number
Interval
Broadcast interval
Broadcast Address
Adding the transmission place.
7
VPL-VW200
3-2. PJ Talk
The remote control service is provided that can control the projector from remote location via network.
3-2-1. Function
This responds to the control command and requests for acquiring the status and information supplied
from clients.
Control request
Enables the input to be selected and picture control to be adjusted.
SIRCS request
Enables remote control by sending the SIRCS code.
Status request
Enables equipment status information such as power status, error information and power-on time to be
acquired.
Information request
Enables equipment information such as equipment name, serial number and installation information to be
acquired.
Protocol
Item
Description
Protocol name
SDCP (Simple Display Control Protocol)
Transport
TCP
Port number
53484 (Factory-shipments value)
TCP connection timeout
30 seconds (Factory-shipments value)
3-2-2. Setup Items
The items that can be set for the PJ Talk service are described below.
Setup item
Description
Port No.
Port number
Timeout
TCP connection timeout time
Host Address
Header community
8
VPL-VW200
3-3. SDAP Protocol
This section describes the SDAP packet structure.
Fig.1 Packet structure
1) Header
The header consists of ID (16 bit), version (8 bit) and category (8 bits).
Fig. 2 Header
ID
It is fixed to “DA”.
Version
This indicates the version number of protocol.
It is fixed to 01h (version 1).
Category
Category number 0Ah of the projector is entered here.
2) Community (Refer to 3-4-1-2.)
The community that is set in the display equipment is entered.
Fig. 3 Community
3) Equipment Information
Product Name
Name of equipment (Maximum twelve characters)
In case, less than twelve characters, 00h is entered in the blank space.
Serial No.
Serial number is entered.
Power Status.
Power supply status of the equipment is entered.
Location
Information of installation location (Maximum twenty four characters)
In case, less than twenty four characters, 00h is entered in the blank space.
Header
(4)
Community
(4)
Product name
(12)
Serial No.
(4)
Location
(24)
Power
Status
(2)
1
1
0
2
3
4
5
6
7
0
9
8
0
1
2
3
4
5
7
6
8
9
0
1
2
3
5
4
6
7
8
9
0
1
(Bit position)
2
3
Version (8)
“DA” (16)
Category (8)
(Bit position)
Community (32)
1
1
0
2
3
4
5
6
7
0
9
8
0
1
2
3
4
5
7
6
8
9
0
1
2
3
5
4
6
7
8
9
0
1
2
3
Page of 28