Sony VPL-HS51A / VPL-HS60 Service Manual ▷ View online

2-1
VPL-HS60/HS51A
Section 2
Electrical Adjustments
2-1. Preparations
2-1-1. Required Equipment
. Oscilloscope
Tektronix 2465 or equivalent
(bandwidth: 350 MHz or more)
. NTSC, PAL, SECAM component signal generator
Tektronix TG2000 
+ AVG1 (optional module) + AWVG1
(optional module) or equivalent
. VG (Programmable video signal generator)
VG854 or equivalent
. Digital voltmeter
Advantest TR6845 or equivalent
. Luminance meter
. Chrominance difference gauge
n
Perform the following adjustments at least 5 minutes after
turning on the power.
2-1-2. Factory Mode Setting
1.
Press the “Setup” key on the MENU.
The “Setup” menu is displayed.
2.
Set the “Status” item to “On”.
3.
Exit the menu.
4.
Press the keys in the following order:
“ENTER” 
→ “ENTER” → “LEFT” → “ENTER”
5.
The message “Do you wish to enter into the
FACTORY MODE?  Yes:
↑  No:↓ ” will be displayed.
6.
Select “Yes:
↑”.
m
. When returning to the USER MODE, perform item 3.
“Do you wish to return to the USER MODE?  Yes:
No:
↓ ” will be displayed.  Select “Yes:↑”.
. Adjustable items (W/B and Device Adjust) of the factory
mode are memorized into the NVM by the memory
operation. At the same time, the factory preset (adjusted)
data are all eliminated from the memory.
After the unit enters and then exits the GAMMA
ADJUSTMENT MODE, be sure to perform “Save to
memory”. If a value is changed in the GAMMA
ADJUSTMENT MODE and the original value cannot be
restored, power off the unit and then power on again. If
the Advance Iris mode in “Cinema Black Pro” of
“Picture Adjust” is changed without performing “Save to
memory” the UF data remains unchanged. Further, if
“Save to memory” is performed then, the UF data
provided for each Iris mode is overwritten and lost.
2-2. V COM Adjustment
1.
Input the green-only XGA 1 Lime ON/OFF signal to
INPUT-A, and set the CONTRAST to 70.
2.
Set the screen to G VCOM adjustment of “Device
Adjust.”
3.
Adjust the G VCOM so that the flicker on the screen is
minimum.
4.
Change the input signal to the red-only and blue-only
1 line ON/OFF signal respectively and adjust R
VCOM and B VCOM respectively so that the flicker
becomes minimum as described in step 3.
5.
Save the value adjusted.
6.
Set the “Image Flip” to either “V” or “HV”.
7.
Input the R/G/B value adjusted as above step 5.
8.
Save the value adjusted.
9.
Set the “Image Flip” to “OFF”.
2-2
VPL-HS60/HS51A
2-3. Adjustment Item Initialize Data
*1:
“Dot Phase, H Size, Shift H/V and Picture Mode” in the “INPUT SETTING” menu have an initial value
respectively in accordance with the input signal (PRESET MEMORY No.).
*2:
VPL-HS51A only
Note: There are nonadjustable items in accordance with the input signal.
MenuTitle
ItemName
Set 
Memory
Off
Status 
Memory
All Input Ch.
Dynamic
Standard
Cinema
User1
*1
15 (
*1)
*1
*1
80
55
60
50
80
Low
Off
High
Film
Off
High
Full
4
4
0
80
50
50
50
50
Off
Off
Middle
Film
Off
Low
Full
4
4
0
80
50
50
50
50
Off
Off
Low
Film
Auto
Low
Full
4
4
0
80
50
50
50
50
Off
Off
Low
Film
Auto
Low
Full
4
4
0
80
50
50
50
50
Off
Off
Low
Film
Auto
Low
Full
4
4
0
80
50
50
50
50
Off
Off
Low
Film
Auto
Low
Full
4
4
0
Red
Adjust
Adjust
0
0
Red
Adjust
Adjust
0
0
Red
Adjust
Adjust
0
0
Picture
Picture Mode
Adjust Picture
Dot Phase
H Size
Shift
Wide Mode
V Position(Zoom)
V Position(Sub Title)
Title Area
Smart APA
Auto Input Search
Standby Mode
Power Saving
RCP
Adjust Signal...
Signal
Function
Picture Memory
RCP Memory
Memory Name
User2
User3
Off
User1
User2
User3
DDE
Cinema Black Pro
Color Select
Position
Range
Color
Hue
Gain R
G
B
Bias R
G
B
Gain R
G
B
Bias R
G
B
Gain R
G
B
Bias R
G
B
Advanced Iris
Lamp Control
Custom1
Custom2
Custom3
Contrast
Brightness
Color
Hue
Sharpness
Black Level Adj.
Gamma Correction
Color Temp.
2-3
VPL-HS60/HS51A
Remarks
Memory Name
Computer
High
Middle
Low
Custom1
Custom2
Custom3
Others
High
Middle
Low
Custom1
Custom2
Custom3
W/B Memory
2-4
VPL-HS60/HS51A
Setup
Status
Language
Input OA Signal Sel.
Color System
V Keystone
Image Flip
Background
Illumination
High Altitude Mode
Network Setting(
*2)
IP Address Setup(
*2)
IP Address(
*2)
Subnet Mask(
*2)
Default Gateway(
*2)
Primary DNS(
*2)
Secondary DNS(
*2)
MAC Address(
*2)
Speed(
*2)
fH
fV
(Memory No.)
(Resolution)
ROM Version
SC ROM Version
IP ROM Version(
*2)
Lamp Timer
Operation Timer
Prev. Lamp Timer
Installation
Information
W/B
Gain R
G
B
Bias R
G
B
MenuTitle
ItemName
Set 
Memory
Status 
Memory
All Input Ch.
Dynamic
Standard
Cinema
User1
On
English
Auto
Auto
0
Off
Blue
On
Off
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Indication only
Picture Memory
RCP Memory
Memory Name
User2
User3
Off
User1
User2
User3
*1:
“Dot Phase, H Size, Shift H/V and Picture Mode” in the “INPUT SETTING” menu have an initial value
respectively in accordance with the input signal (PRESET MEMORY No.).
*2:
VPL-HS51A only
Note: There are nonadjustable items in accordance with the input signal.
Page of 127
Display

Click on the first or last page to see other VPL-HS51A / VPL-HS60 service manuals if exist.