DOWNLOAD Sony VPL-AW10 / VPL-AW15 Service Manual ↓ Size: 8.66 MB | Pages: 102 in PDF or view online for FREE

Model
VPL-AW10 VPL-AW15
Pages
102
Size
8.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector
File
vpl-aw10-vpl-aw15.pdf
Date

Sony VPL-AW10 / VPL-AW15 Service Manual ▷ View online

1-17
VPL-AW10/AW15
1-3-18. F Board
9 Two claws
     (+PSW M3 
x 8)
4 Screw
     (+PSW M3 
x 8)
!- F board
3 Two screws
     (+BVTP 3 
x 12)
!= Screw
     (+PSW 4 
x 8)
0 Open the clamp
Shield case (F),
F board cover (B), Sheet (F)
![ Two claws
     (+K M3 
x 8)
!] AC inlet
7 Shield cover (F)
8 F board cover (T)
5 Five dowels
2 Open the clamp
CN002
CN001
1 Tape
6 Claw
1-18
VPL-AW10/AW15
1-3-19. Extension Boards and Extension Cables
A Flat connector assembly (32P) x 3
B Flat connector assembly (24P)
X kit assembly (A-1309-488-A)
X board
F Connector assembly (4P)
C ZH connector assembly (8P)
G Connector assembly (7P)
H Connector assembly (8P)
D GH connector assembly (6P)
E GH connector assembly (9P)
I Connector assembly (9P)
J Connector assembly (13P)
CN400
CN600
CN10400
CN10600
CN1000
CN11000
CN11201
CN1201
CN1200
CN11200
CN701
CN702
CN703
CN10701
CN10702
CN10703
CN10705
CN705
CN1300
CN11300
CN900
CN1100
CN11100
CN10900
Front Side
of Unit
1-3-20. Removing the C Board
H board
Top Cover Assembly 
Shield 
cover (C)
FFC clamp 
x 3
Shield cover (G)
Q board
C board
C board section
1-19
VPL-AW10/AW15
1-3-21. C Board Extension Connentions
J
I
E
G
C
A x 3
B
F
D
H
CN12
CN60
Q board
C board
X board
H board
X board
CN400
CN600
CN10400
CN10600
CN1000
CN11000
CN11201
CN1201
CN1200
CN11200
CN701
CN702
CN703
CN10701
CN10702
CN10703
CN10705
CN1300
CN11300
CN900
CN1100
CN11100
CN10900
C board
CN400
CN600
CN1000
CN1201
CN1200
CN701
CN702
CN703
CN1300
CN900
CN1100
CN705
CN705
A Flat connector assembly (32P) x 3
B Flat connector assembly (24P)
C ZH connector assembly (8P)
D GH connector assembly (6P)
E GH connector assembly (9P)
F Connector assembly (4P)
G Connector assembly (7P)
H Connector assembly (8P)
I Connector assembly (9P)
J Connector assembly (13P)
Front Side
of Unit
1-20
VPL-AW10/AW15
1-4. Unleaded Solder
Boards requiring use of unleaded solder are printed with a
lead free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come
printed with the lead free mark due to their particular size.)
 : LEAD FREE MARK
m
. Be sure to use the unleaded solder for the printed circuit
board printed with the lead free mark.
. The unleaded solder melts at a temperature about 40 dC
higher than the ordinary solder, therefore, it is recom-
mended to use the soldering iron having a temperature
regulator.
. The ordinary soldering iron can be used but the iron tip
has to be applied to the solder joint for a slightly longer
time. The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful.
1-5. Service Know-How
1-5-1. When the Optical Unit ASSY is
Replaced
1.
Write the Look Up Table/3D gamma data contained in
the attached floppy disk.
See “1-6. Writing Look Up Table/3D gamma/DDC
data” for more about how to write data.
2.
Perform white balance adjustment. (See “2-5. White
Balance Adjustment on servicing”)
3.
Change the IRIS data to the values of the IRIS adjust-
ment data stored in the supplied floppy disk. For how
to change the data, refer to “1-5-3. IRIS Copy”.
1-5-2. When the Board is Replaced
1) When the C board is replaced
a)
Remove IC803 from the old C board and install it
to the new board.
b) Perform V COM adjustment according to section
2-3.
c)
Change the IRIS data to the values of the IRIS
adjustment data before replacement. (For the
method to change the IRIS data, refer to “1-5-3.
IRIS Copy”.)
When the adjustment data cannot be copied, adjust
IRIS. (Refer to “2-4. IRIS Adjustment”.)
d) Change the W/B data to the values of the W/B
adjustment data before replacement. (For the
method to change the W/B data, refer to “1-5-4.
W/B Copy”.)
When the adjustment data cannot be copied, adjust
W/B. (Refer to “2-5. White Balance Adjustment
on servicing”.)
2) When other boards than above are replaced
No particular adjustments are needed.
1-5-3. IRIS Copy
1.
Enter the Service Mode. (Refer to “2-1-2. Service
Mode Setting”.)
2.
Set Other: 01/Iris Adj in the Device Menu to 1.
3.
Change the value of Other: 02/Iris Open Reg.
4.
Change the value of Other: 03/Iris Close Reg.
5.
Return Other: 01/Iris Adj in the Device Menu to 0.
6.
Perform Save to Memory.
1-5-4. W/B Copy
1.
Input the 720/60P  flat-field to the component termi-
nal.
2.
Enter the Service Mode. (Refer to “2-1-2. Service
Mode Setting”.)
3.
Enter the W/B mode in the Device Menu.
4.
Change the values of Gain R/G/B and Bias R/G/B in
each mode (High/Middle/Low/Custom1/Custom2/
Custom3).
5.
Perform Save to Memory.
* W/B data has a memory for each of the three IRIS modes (AUTO1/2,
Manual, and OFF for AW15; and AUTO, ON, and OFF for AW10).
Perform the above steps for each IRIS mode.
6.
Input the computer signal to input A, and copy all the
W/B adjustment values just as for Component.
Page of 102
Display