7. Communication Rules
. When sending a command from CONTROLLER, the return data (CMD1 = 10 hex or CMD1 = each
category value, CMD2 = 03 hex) from PROJECTOR should be received first before sending the next
command. Even if the next command is sent before receiving the return data, since PROJECTOR will
not be able to receive that command, it does not return a response to CONTROLLER. Consequently, no
error code is also sent.
The following lists the approximate waiting times for PROJECTOR to return the return data after
CONTROLLER sends the command.
. When a communication error occurs, PROJECTOR ignores the data received until now, and set into the
reception standby state.
. For undefined commands or commends determined as invalid by PROJECTOR, PROJECTOR will
send the “NAK” return data to CONTROLLER .
. Take note that when data is written when the input signal of PROJECTOR is unstable, that data (value)
will not be incorporated.
. When INDEX specified SIRCS direct command (CMD1 = 17 hex) is transmitted, leave an interval of
45 mSec until the next transmission. (Do not return the return data (ACK, NAK) when the SIRCS
direct command is received.)
8. Approximate Return Waiting Times
Note: The times shown in this table are when communication is performed in the condition that it
will not be interrupted by some reason.
CMD1
00
00
01
01
01
03
03
CMD2
00
01
01
00
01
00
00
DATA1
_
_
00
00
00
00
01
DATA2
_
_
01, 02
05
05
_
_
TIME (mSec)
20
20
20
20
20
25
20
9
VPL-VW11HT
9
9. Commands
Regarding to [DATA1], and [DATA2], they could be devised only in the function category of [ADJUST SET] or [ADJUST GET].
The meaning of [ADJUST REPLY]’s set value ([DATA8], [DATA9]) is the same as the set value ([DATA4], [ DATA5]) when it is in the function category of [ADJUST GET].
CMD1
CMD2
DATA1
DATA2
DATA3
DATA4
DATA5
DATA6
DATA7
DATA8
DATA9
FUNCTION
ADJUST SET
Category
Value
00h
00h
ADJUST ACK/NAK
03h
N/A
ADJUST GET
01h
N/A
<ADJ USER NO>
Please refer to the
Table of ADJ USER NO
OPTION
02h
<Set Value>
Please refer to the 
Table of Set Value
UPPER 
The maximum value that
is possible to set
<Set Value>
Please refer to the 
Table of Set Value
LOWER
The minimum value that
 is possible to set
N/A
ADJUST REPLY
02h
VALID
00h
ACK/NAK
DATA
DATA1
DATA2
DATA4
DATA5
SET
GET
STANBY
START
SEQUENCE
POWER ON
COOLING1
COOLING2
SAVING
COOLING1
SAVING
COOLING2
SAVING
STANBY
00h
00h
00h
01h
00h
02h
00h
03h
00h
00h
00h
01h
00h
02h
00h
03h
00h
04h
00h
05h
COLTEMP
00h
17h
CUSTOM1
CUSTOM2
CUSTOM3
CUSTOM4
POWER STATUS
HIGH
LOW
Current set value
RGBENHANCER
00h
15h
Current set value
SHARPNESS
00h
14h
00h
Current set value
HUE
00h
13h
Current set value
COLOR
00h
BRIGHTNESS
00h
11h
12h
FUNCTION
00h
01h
INPUT
ADJ USER NO
00h
10h
CONTRAST
INPUT A
INPUT B
Current set value
00h
00h ~ 64h
SET VALUE
Items for Selection
Current set value
VIDEO
S-VIDEO
00h
00h
00h
00h
OPERATION
(0 ~ 100)
O
(0 ~ 100)
O
(0 ~ 100)
O
(0 ~ 100)
O
(0 ~ 100)
O
(0 ~ 100)
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
00h ~ 64h
00h ~ 64h
00h ~ 64h
00h ~ 64h
00h ~ 64h
ADJUST CATEGORY
10
VPL-VW11HT
10
00h
00h
00h
01h
00h
02h
00h
03h
00h
04h
00h
05h
00h
06h
00h
01h
00h
00h
00h
01h
00h
00h
00h
00h
00h
01h
00h
02h
00h
03h
00h
00h
00h
01h
00h
02h
00h
03h
-
85h
Current set value
Current set value
Current set value
00h ~ FFh
DTV-YPBPR
DTV-GBR
COMPONENT
BIAS BLUE
00h
Current set value
BIAS GREEN
00h
00h
00h ~ FFh
00h
00h ~ FFh
00h
84h
BIAS RED
00h
83h
Current set value
(0 ~ 255)
(0 ~ 255)
(0 ~ 255)
(0 ~ 255)
(0 ~ 255)
(0 ~ 255)
GAIN BLUE
00h
82h
GAIN GREEN
00h
81h
00h
GAIN RED
00h
80h
Current set value
INPUT B
00h
33h
COMPUTER
COMPONENT
COMPUTER
INPUT A
00h
32h
DTV-GBR
DTV-YPBPR
ASPECT
00h
30h
OFF
ON
PICTURE MUTING
SCANCONV
00h
21h
OFF
ON
00h
20h
WIDE ZOOM
FULL
00h ~ FFh
00h
00h ~ FFh
00h
00h ~ FFh
SUBTITLE
FULL THROUGH
NORMAL
NORM. THROUGH
ZOOM
DATA1
DATA2
DATA4
DATA5
SET
GET
STANBY
START
SEQUENCE
POWER ON
COOLING1
COOLING2
SAVING
COOLING1
SAVING
COOLING2
SAVING
STANBY
POWER STATUS
FUNCTION
ADJ USER NO
SET VALUE
Items for Selection
OPERATION
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
11
VPL-VW11HT
11
SIZE
DATA1
DATA2
DATA3
DATA4
DATA5
DATA6
DATA7
SET
GET
STANBY
START
SEQUENCE
POWER ON
COOLING1
COOLING2
SAVING
COOLING1
SAVING
COOLING2
SAVING
STANBY
00h
01h
02h
04h
08h
10h
20h
40h
00h
01h
02h
03h
04h
05h
06h
07h
08h
00h
01h
POWER STATUS
FUNCTION
DU USER NO
02h
NO ERROR
LAMP ERROR
FAN ERROR
COVER ERROR
TEMP ERROR
STARTUP LAMP
POWER ON
COOLING1
COOLING2
POWER STATUS
00h
D5V ERROR
POWER ERROR
WARNING ERROR
STANBY
ERROR STATUS
00h
01h
START UP
TOTAL LAMP
TIMER
00h
13h
CONTROL MODE
SELECT
00h
05h
TOTAL LAMP TIMER
N/A
SAVING STANBY
USER
N/A
0000h   FFFFh
SAVING COOLING2
N/A
N/A
SERVICE
01h
02h
01h
01h
OPERATION
THE MEANING OF THE DATA
SET VALUE
SAVING COOLING1
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
CMD1
CMD2
DATA1
DATA2
DATA3
DATA4
DATA5
DATA6
DATA7
DATA
DU ACK/NAK
03h
ACK/NAK
DATA
N/A
<DU USER NO> 
Form of DU USER NO.
Please refer to the
SIZE  Please
refer to the table
<Set Value>  Please refer to the Table of Set Value
DU GET
01h
SIZE Please refer
to the table
N/A
DU REPLY
02h
SIZE Please refer
to the table
FUNCTION
DU SET
Category
Value
01h
00h
DU CATEGORY
The command outside the [CONTROL MODE SELECT] could be made only through the function of GET.
Regarding to the meaning of the data of [DU REPLY], it is the same as <Set Value>.
Page of 21
Display

Click on the first or last page to see other RM-PJVW10 / VPL-VW11HT (serv.man2) service manuals if exist.