DOWNLOAD Sony RM-PJVW10 / VPL-VW11HT (serv.man2) Service Manual ↓ Size: 237.23 KB | Pages: 21 in PDF or view online for FREE

Model
RM-PJVW10 VPL-VW11HT (serv.man2)
Pages
21
Size
237.23 KB
Type
PDF
Document
Service Manual
Brand
Device
Projector / PROTOCOL MANUAL
File
rm-pjvw10-vpl-vw11ht-sm2.pdf
Date

Sony RM-PJVW10 / VPL-VW11HT (serv.man2) Service Manual ▷ View online

3
VPL-VW11HT
4. Data of Code
1
1
1
1
1
Start Condition
2
2
2
2
2
INDEX Header
/
*--
RECEIVER INDEX
--
*/
/
*--
SENDER INDEX
--
*/
/
*--
Command
--
*/
Note: CMD1 and CMD2 are assigned with different commands for each unit. Consequently,
there is no compatibility of commands between units. For details of the commands, refer
to the respective list of commands for the units. Since there is no index function of this
unit, the receiver INDEX will be ignored even if the command is designated.
3
3
3
3
3
Sub Data Size
Note: Error when 82 to FF hex codes are included.
4
4
4
4
4
Data Size 2
Note: Error when 01 to FF hex codes are included.
B1
B2
B3
B4
B5
PERIPHERAL INDEX
GROUP INDEX UPPER BYTE
GROUP INDEX LOWER BYTE
DEVICE INDEX UPPER BYTE
DEVICE INDEX LOWER BYTE
01
00
01
00
01
01: Projector
Group Index = 0001 hex
Device Index = 0001 hex
B6
B7
B8
B9
B10
PERIPHERAL INDEX
GROUP INDEX UPPER BYTE
GROUP INDEX LOWER BYTE
DEVICE INDEX UPPER BYTE
DEVICE INDEX LOWER BYTE
03
00
01
00
01 - 63
01: Controller
Group Index = 0001 hex
Device Index = 0001 - 0063 hex
B15
Data Length 2
00 0: 
Fixed
B14
Data Length 1
02  81
(B16 
+
 2) hex Data Size
Bn
B0
NAME
Start Code
DATE
(hex)
A5
NOTE
Indicates the first packet
Projector All
LCD Projector  All
VPL-PX20, VPL-PX30, VPL-VW10HT, VPL-VW11HT only 
B11
B12
B13
CMD1
CMD2
CMD3
00
80
90
Refer to attached
Refer to attached
4
VPL-VW11HT
5
5
5
5
5
Data Size 3
Note: Error when 80 to FF hex codes are included.
6
6
6
6
6
Data
Bn = B16 
+ 1
Bm = B16 
+ Total Data Length
7
7
7
7
7
Check SUM
XOR is the exclusive OR.
It is as follows when calculated by 1 bit.
Taking A XOR B = C;
A
B
C
0
0
0
1
0
1
0
1
1
1
1
0
<Example of Calculation>
When 0XA5 (165) and 0XA5 (165) are calculated by XOR;
A5
10100101
(165)
A5
10100101
(165)
Answer
00000000
(0)
When 0XA5 (165) and 0X5A (90) are calculated by XOR;
Answer
A5
10100101
(165)
5A
01011010
(90)
Answer
11111111
(255)
8
8
8
8
8
End Condition
B16
Data Length 3
00  7F
Size of 
6
Bn - Bm Data
XX
No Data in some cases
Bm 
+
 1
Check Sum
XX
Check sum of Data from 
2
 to 
6
(Calculate the XOR of the Data from 
2
 to 
6
)
Bm 
+
 2
END Code
5A
Indicates the last packet
5
VPL-VW11HT
5. Connection
<RS-232C Connection>
Communication is enabled by the use of a D-Sub 9 Pin cross (reverse) cable.
The pin assignment of D-Sub 9 Pin and D-Sub 25 Pin is as follows.
Pins indicated as D-Sub 25 Pin are not used.
Assured cable length: 15 m (However, assurance may not be applicable for some cables.)
The software for controlling the projector from a PC is intended for performing transmission and recep-
tion for only the TxD and RxD lines.
Therefore there is no handshake normally performed by RS-232C.
D-Sub 9 Pin
Shell = FG
3
2
7
8
6
5
1
4
9
D-Sub 25 Pin
1
2
3
4
5
6
7
8
20
22
Name
FG
TxD
RxD
RTS
CTS
DSR
SG
DCD
DTR
RI
Grounding for safety protection or cable shield
Transmission data
Reception data
Transmission request
Transmission permission
Data set ready
GND for signal
Data channel signal carrier detection
Data terminal ready
Calling display (Presence/absence of calling signal)
6
VPL-VW11HT
6. Communication Procedure
6-1. Outline of Communication
All communication between CONTROLLER (PC, etc.) and DEVICE (PROJECTOR) is performed by the
command block format. Communication is started by the issue of a command at CONTROLLER and
ended when the return data is sent to CONTROLLER after DEVICE receives the command.
CONTROLLER is prohibited from sending several commands at one time. This means that after CON-
TROLLER sends one command, it cannot send other commands until DEVICE returns the return data.
DEVICE sends the return data after processing the command. The time from when CONTROLLER sends
the command until the return data is returned differs according to the contents of the command.
In some cases, CONTROLLER may receive data from DEVICE even though it has not sent a command.
(For example, during SYS setting, SIRCS command, and switcher information when switcher is selected.)
Note: When Sircs Direct Command (CMD1 = 17 hex) is sent, return data may not be returned in
some cases.
6-2. Reading the Command Tables
The command tables can be found in Section 9 (page 11).
CMD1 indicates the command category. The ACK from the projector is returned attached with the
command category sent from the controller. However, when errors of the communication line occur, 10
hex (COMMON) will be returned.
CMD2 indicates the command processing method and processing results. 00 hex (SET) is set when
setting data from the controller to the projector or when requesting for data processing. 01 hex (GET) is
set when acquiring data. 2 hex (RETURN) is set when returning the ACK of the command received from
the projector to the controller and when attaching data. 03 hex (ACK) is set when returning only the
processing results.
However, F0 hex (COMM NAK) is set when the command the projector receives from the controller has
a communication line error or checksum inconsistency.
The top of each category indicates the meaning of the data.
Page of 21
Display

Click on the first or last page to see other RM-PJVW10 / VPL-VW11HT (serv.man2) service manuals if exist.