Sony RM-PJM12 / VPL-CS5 / VPL-CX5 Service Manual ▷ View online

2-5
VPL-CS5/CX5
.
.
Device
Item Name
Memory Name
Remark
Name
Set Memory Status Memory
Chroma Memory
Channel Memory
Image Flip Memory
NT358/
Pal/Pal-M/
15kRGB
Component
Video
S Video
Input-A
MS
Up/Down
Up/Down
NT443/
N/Secam/
(15k)
inversion is inversion is
BW60
BW50
possible
impossible
A/D
ADC/
Clamp Position
8
Fixed value
Converter
Clamp Width
20
Fixed value
R Gain
100
Fixed value
G Gain
100
Fixed value
B Gain
100
Fixed value
R Offset
128
Fixed value
G Offset
128
Fixed value
B Offset
128
Fixed value
Sync Sep Th 32
Fixed value
Pre Coast
2
Fixed value
Post Coast
8
Fixed value
Chroma/
Chroma/ Ch1 Gain
20
20
144
144
D.Comb
Ch2 Gain
144
16
160
160
Video Brt
140
124
128
128
Fixed value
Video Cont
64
64
64
64
Fixed value
Sub Color
56
56
56
56
Fixed value
LCBW
0
0
0
0
Fixed value
Y-DeLay
*
Fixed value
Ch3 Gain
144
144
160
160
Ch4 Gain
144
144
160
160
YUV Brt
128
128
128
128
Fixed value
YUV Cont
64
64
64
64
Fixed value
AOSL
_
1E
Display only
1F
Display only
2-6
VPL-CS5/CX5
Device
Item Name
Memory Name
Remark
Name
Set Memory Status Memory
Chroma Memory
Channel Memory
Image Flip Memory
NT358/
Pal/Pal-M/
15kRGB
Component
Video
S Video
Input-A
MS
Up/Down
Up/Down
NT443/
N/Secam/
(15k)
inversion is inversion is
BW60
BW50
possible
impossible
Panel
P.Drv
Offset R
214
214
Driver
Offset G
214
214
Offset B
214
214
V Common R
55/65
55/65
V Common G
55/65
55/65
V Common B
55/65
55/65
Psig 1
58/138
Fixed value
Psig 2
135/53
Fixed value
Signal Center 193
Gain R
166
Gain G
166
Gain B
166
DCFB Off
1
Fixed value
Sample
SH1
7/8
Fixed value
Hold/
Other/
V Com Ptn Enb Adj. not possible
Installation
0
Other
3D
Sub Cont
0
Fixed value
Gamma
Sub Brt
0
Fixed value
R Osd Lvl
31
Fixed value
G Osd Lvl
31
Fixed value
B Osd Lvl
31
Fixed value
Through
0
Fixed value
SW
1
Fixed value
APC Thres
25
Fixed value
APC Limit
32
Fixed value
2-7
VPL-CS5/CX5
Device
Item Name
Memory Name
Remark
Name
Set Memory Status Memory
Chroma Memory
Channel Memory
Image Flip Memory
NT358/
Pal/Pal-M/
15kRGB
Component
Video
S Video
Input-A
MS
Up/Down
Up/Down
NT443/
N/Secam/
(15k)
inversion is inversion is
BW60
BW50
possible
impossible
Other
Other/
V Start
22
Fixed value
H Start (MSB) 104/144
Fixed value
H Start (LSB) 0/1
Fixed value
H Position
33/11
Fixed value
HST Position 9
Fixed value
HST Phase 3/6
Fixed value
Temp Lamp
Adj. not possible
Fixed value
Temp Panel
Adj. not possible
Fixed value
Fan1 H
Adj. not possible Adj. not possible
Fixed value
Fan1 L
Adj. not possible Adj. not possible
Fixed value
Fan2 H
Adj. not possible Adj. not possible
Fixed value
Fan2 L
Adj. not possible Adj. not possible
Fixed value
Fan3 H
Adj. not possible Adj. not possible
Fixed value
Fan3 L
Adj. not possible Adj. not possible
Fixed value
Synchronous 1
Fixed value
Tilt C0
0
Tilt C1
10000
Tilt C2
_
10000
X Tilt
Display only
Y Tilt
Display only
TL
Display only
TP
Display only
Gamma
Factory
adjustment value
m
. There are some adjustment items that cannot be adjusted, depending on the input signal.
. The items showing two digits such as “7/8” the following meaning : Left digit : VPL-CS5, Right digit : VPL-CX5
. * : The value changes depending on the color systems and input terminals.
2-8
VPL-CS5/CX5
2-4. Service Know-How
2-4-1. When the Prism Block Is Replaced
1.
Perform the V COM adjustment. (Refer to Section “2-
2. VCOM Adjustment”.)
2.
Write the GAMMA data of the prism block.
3.
Perform the white balance adjustment. (Refer to
Section “2-5. White Balance Adjustment”.)
2-4-2. When the C Board Is Replaced
n
If any board other than the C board is replaced, there is not
adjustment item.
1.
Install IC406 of the C board before replacement, into
the new C board.
2.
Enter the Factory Mode.
3.
Place this model on a flat worktable. Press the TILT
key on a flat table so that the lens shutter becomes
visible a little when viewed from the front of the
model.
4.
Operate the TILT
+ key and stop it at the point that the
lens shutter becomes invisible from the front.
5.
From this position, flip the TILT
+ key twice.
6.
Press the keys as follows [ENTER] 
 [ENTER] 
[POSITION+] 
→ 
[MEMORY] keys. (Memorizing
the adjustment value.)
7.
With the model being placed on a flat worktable, open
the lens shutter fully open while the adjuster does not
touch the ground.
8.
Write the X TILT value in C0 at this time.
9.
Point the model vertically upright and fix the position.
10. Write the X TILT value in C1 at this time.
11. Point the model vertically downward and fix the
position.
12. Write the X TILT value in C2 at this time.
13. Perform the V COM adjustment. (Refer to Section “2-
2. VCOM Adjustment”.)
14. If the white balance is significantly poor, perform the
white balance adjustment. . (Refer to Section “2-5.
White Balance Adjustment”.)
2-5. White Balance Adjustment
Preparation before adjustment
1.
Input the 100 IRE flat field signal to the INPUT-A
connector and allow the warm-up of 10 minutes aging
at a minimum.
2.
Enter the Service Mode.
Press the keys in the following order.
[ENTER] 
 [ENTER] 
→ 
 
 
 →
 
 ↓
 
 → 
[ENTER].
The message [Do you want to enter the Service Mode?
Yes : 
↑ 
 No : 
] appears.
Select [Yes : 
].
[Supplementary information: How to Exit the
Service Mode]
Perform the step 2 KEY operation.
The message [Do you want to return to the User Mode?]
appears.
Select [Yes : 
].
2-5-1. HIGH Mode of INPUT-A
Connect the10-step signal to the INPUT-A connector and
measure the chromaticities at each brightness.
If chromaticities are different at each brightness, perform
the following adjustment.
1.
Input the 100 IRE flat field signal to the INPUT-A
connector.
2.
Measure the chromaticity (x, y).
3.
Input the 80 IRE flat field signal.
4.
Adjust the GAIN R and GAIN B in the HIGH mode of
W/B until the chromaticity (x, y) that is measured at
step 2 is obtained.
5.
Input the 30 IRE flat field signal.
6.
Adjust the BIAS R and BIAS B in the HIGH mode of
W/B until the chromaticity (x, y) that is measured at
step 2 is obtained.
7.
Repeat steps 3 to 6 until the chromaticity (x 
±
0.002, y
±
0.004) with reference to the chromaticity (x, y) that
is measured at step 2 is obtained.